Through two-dimensional numerical simulations, we analyzed the effects of new cell structure for the luminous efficacy improvement in an ac plasma display panel. In the new structure with 5 electrodes, two auxiliary electrodes are arranged between X and Y electrodes with long gap. Through the application of adequate auxiliary pulse on the address electrode, the luminous efficacy in the new cell structure showed the improvement of 52[%] in comparison with that of conventional cell structure with short gap between X and Y electrodes. Consequently, as the short gap discharge between auxiliary electrodes decreases and the long gap discharge between X and Y electrodes increases, the result of VUV generation efficacy shows higher improvement. The reliability of simulation result could he confirmed by the experimental result in the test panel.

본 논문은 수치 해석을 이용한 교류형 플라즈마 표시기의 발광 효율 개선에 대한 연구를 주 내용으로 하고 있으며, 긴 전극 간격을 가지는 유지 전극들 사이에 2개의 보조 전극을 삽입한 5전극 신 구조에서의 방전 특성에 대해 분석하였다. 2차원의 수치 해석 결과에 의하면 어드레스 전극에 보조 펄스가 인가되는 구동 파형을 적용했을 때, 신 구조는 일반적인 3전극 면방전 구조에 비해 대략 52[%]의 효율 증가를 보였다. 결과적으로 방전 초기에 보조 전극 사이에서 일어나는 방전의 크기는 축소되고 주방전에 해당하는 유지 전극 사이의 긴 간격에서의 방전은 확장될수록 플라즈마 표시기의 유지 방전에 있어서 VU V생성 효율의 개선 효과는 커진다고 볼 수 있다. 이와 같은 수치 해석 결과에 대한 신뢰성은 실험 결과를 제시함으로써 검증할 수 있다.

Keywords

References

  1. H. S. Jeong, B. J. Shin, and K.-W. Whang, "Two-dimensional multifluid modeling of the He-Xe discharge in an ac plasma display panel," IEEE Trans. Plasma Sci., Vol. 27, No. 1, pp. 171-181, 1999 https://doi.org/10.1109/27.763110
  2. C. Punset, S.Cany, and J. P. Boeuf, "Addressing and sustaining in ac coplanar plasma display panels," J. Appl. Phys., Vol. 86, No. 1, pp. 124-133, 1999 https://doi.org/10.1063/1.370709
  3. Kyung Cheol Choi, Nam Hoon Shin, Kyo Sung Lee, Bhum Jae Shin, Seong-Eui Lee, "Study of Various Coplanar Gaps Discharges in ac Plasma Display Panel," IEEE Trans. Plasma Sci., Vol. 34, No. 2, pp. 385-389, 2006 https://doi.org/10.1109/TPS.2006.872456
  4. 서정현, 교류형 플라즈마 표시기에서의 He-Ne-Xe 혼합가스의 방전특성 연구, 서울대학교 대학원 공학박사 학위논문, 2000.
  5. Hyun Sook Bae, Joong Kyun Kim, and Ki-Woong Whang, "The Effects of Sustain Electrode Gap Variation on the Luminous Efficacy in Coplanar-Type AC Plasma Display Panel under Low- and High-Xe Content Conditions," IEEE Trans. Plasma Sci., Vol. 35, No. 2, pp. 467-472, April, 2007 https://doi.org/10.1109/TPS.2007.892738
  6. Tae Jun Kim, Joong Kyun Kim, and Ki-Woong Whang, "High Luminous Efficacy Characteristics of Long Gap Structure AC Plasma Display Panel with Self-Ignition Electrodes," IEEE Trans. Plasma Sci., Vol. 35, No. 6, pp. 1775-1780, December 2008 https://doi.org/10.1109/TPS.2007.907906
  7. Heung-Sik Tae, Hyun Ju Seo, Dong-Cheol Jeong, Jeoung Hyun Seo, Hyun Kim, Ki-Woong Whang, "Analysis of Microdischarge Characteristics Induced by Synchronized Auxiliary Address Pulse Based on Cross-Sectional Infrared Observation in AC Plasma Display Panel," IEEE Trans. Plasma Sci., Vol. 33, No. 2, pp. 993-999, 2005