• 제목/요약/키워드: additive manufactured

검색결과 180건 처리시간 0.027초

마이크로 드로플릿 셀 기법과 임계공식온도 측정 기법을 이용한 적층가공 Ti-6Al-4V 합금의 내식성 평가 (Ti-6Al-4V Alloy Fabricated by Additive Manufacturing Method Using Micro-droplet Cell and Critical Pitting Temperature Techniques and Evaluation of its Resistance to Corrosion)

  • 서동일;이재봉
    • Corrosion Science and Technology
    • /
    • 제17권3호
    • /
    • pp.129-137
    • /
    • 2018
  • The resistance to corrosion of additive manufactured (3D printing) Ti-6Al-4V alloys was investigated using micro-electrochemical tests. In terms of corrosion resistance, the acicular martensitic ${\alpha}^{\prime}$ phase in such additive manufactured Ti-6Al-4V was the focus of attention, and its behavior was distinct from that of conventional subtractive manufactured Ti-6Al-4V. To order to identify ${\alpha}^{\prime}$ phase, XRD tests were performed and micro Vickers hardness was measured for different grains (bright and dark grains) in the additive manufactured Ti-6Al-4V alloy. Micro-electrochemical tests were performed to measure corrosion resistance of bright and dark grains in the additive manufactured Ti-6Al-4V alloy with specially designed electrochemical micro-droplet cell. Critical pitting temperature (CPT) measurement was performed to evaluate the resistance to pitting corrosion of additive manufactured Ti-6Al-4V alloys with different volumes of ${\alpha}^{\prime}$ phase and subtractive manufactured Ti-6Al-4V alloy. The dark grains of the laminated Ti-6Al-4V alloy distributed broader than the bright grains measured with low microhardness. The dark grains of the Ti-6Al-4V alloy, which was rich in martensite ${\alpha}^{\prime}$, had lower general corrosion and pitting resistance than bright grains. As the fraction of martensite ${\alpha}^{\prime}$ phase increased, the resistance to the pitting corrosion decreased.

Study on Corrosion Properties of Additive Manufactured 316L Stainless Steel and Alloy 625 in Seawater

  • Jung, Geun-Su;Park, Yong-Ha;Kim, Dae-Jung;Lim, Chae-Seon
    • Corrosion Science and Technology
    • /
    • 제18권6호
    • /
    • pp.258-266
    • /
    • 2019
  • The objective of this study was to evaluate corrosion resistance of additive manufactured 316L stainless steel and alloy 625 powders widely used in corrosion resistance alloys of marine industry in comparison with cast alloys. Directed Energy Deposition (DED) method was used in this work for sample production. DED parameter adjustment was also studied for optimum manufacturing and for minimizing the influence of defects on corrosion property. Additive manufactured alloys showed lower corrosion resistance in seawater compared to cast alloys. The reason for the degradation of anti-corrosion property was speculated to be due to loss of microstructural integrity intrinsic to the additive manufacturing process. Application of heat treatment with various conditions after DED was attempted. The effect of heat treatments was analyzed with a microstructure study. It was found that 316L and alloy 625 produced by the DED process could recover their expected corrosion resistance when heat treated at 1200 ℃.

High-Efficiency Cooling System Using Additive Manufacturing

  • Yeong-Jin Woo;Dong-Ho Nam;Seok-Rok Lee;Eun-Ah Kim;Woo-Jin Lee;Dong-Yeol Yang;Ji-Hun Yu;Yong-Ho Park;Hak-Sung Lee
    • Archives of Metallurgy and Materials
    • /
    • 제66권3호
    • /
    • pp.689-693
    • /
    • 2021
  • In this study, we propose a cooling structure manufactured using a specialized three-dimensional (3D) printing design method. A cooling performance test system with complex geometry that used a thermoelectric module was manufactured using metal 3D printing. A test model was constructed by applying additive manufacturing simulation and computational fluid analysis techniques, and the correlation between each element and cooling efficiency was examined. In this study, the evaluation was conducted using a thermoelectric module base cooling efficiency measurement system. The contents were compared and analyzed by predicting the manufacturing possibility and cooling efficiency, through additive manufacturing simulation and computational fluid analysis techniques, respectively.

Ti-6Al-4V 합금 기지 위에 FGM 방식으로 적층제조 된 Inconel 718의 접합 특성 분석 (Joint Properties of Inconel 718 Additive Manufactured on Ti-6Al-4V by FGM method)

  • 박찬웅;박진웅;정기채;이세환;김성훈;김정한
    • 한국분말재료학회지
    • /
    • 제28권5호
    • /
    • pp.417-422
    • /
    • 2021
  • In the present work, Inconel 718 alloy is additively manufactured on the Ti-6Al-4V alloy, and a functionally graded material is built between Inconel 718 and Ti-6Al-4V alloys. The vanadium interlayer is applied to prevent the formation of detrimental intermetallic compounds between Ti-6Al-4V and Inconel 718 by direct joining. The additive manufacturing of Inconel 718 alloy is performed by changing the laser power and scan speed. The microstructures of the joint interface are characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and micro X-ray diffraction. Additive manufacturing is successfully performed by changing the energy input. The micro Vickers hardness of the additive manufactured Inconel 718 dramatically increased owing to the presence of the Cr-oxide phase, which is formed by the difference in energy input.

NaCl과 NaBr수용액에서 적층가공으로 제조된 Ti-6Al-4V 합금의 공식 저항성 비교 (Comparing Resistances to Pitting Corrosion of Additive Manufactured Ti-6Al-4V Alloys in NaCl and NaBr Aqueous Solutions)

  • 서동일;이재봉
    • Corrosion Science and Technology
    • /
    • 제18권3호
    • /
    • pp.110-116
    • /
    • 2019
  • Resistances to pitting corrosion of additive manufactured (AM) Ti-6Al-4V alloys in 0.6 M NaBr and 0.6 M NaCl aqueous solutions were compared using micro-droplet cell techniques. With respect to the pitting corrosion resistance, this study focused on two different types of halide anions in aqueous solutions, i.e. $Br^-$ and $Cl^-$. The differences between $Br^-$ and $Cl^-$ halide anions for breakdown on passive films of AM Ti-6Al-4V alloy were explained using Langmuir adsorption model with their equilibrium adsorption coefficients. The results of the analysis showed that the lower resistance to pitting potential of AM Ti-6Al-4V alloy in $Br^-$ aqueous solution was attributed to the higher equilibrium adsorption coefficient of Br-. In addition, micro-electrochemical test results showed that the pitting corrosion resistance of dark grains in additive manufactured Ti-6Al-4V alloy was lower as compared to that of bright grains due to the larger volume of ${\alpha}^{\prime}$ phase that caused the susceptibility to pit initiation.

첨가법에 의해 제작된 단관의 내면 적합도 분석 (Analysis of internal fitness of single crown fabricated by additive method)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Purpose: The purpose of this study was to analysis the internal fitness of single crown fabricated by additive method technique. Methods: Study models were fabricated. Ten crowns were manufactured by additive method technique (AM group) and another ten crowns using conventional method were manufactured (CM group). The internal fitness of specimens were measured using silicone replica technique. Silicone replicas were sectioned one times (direction: from mesial to distal). The internal fitness were evaluated using by digital microscope. Statistical analyses were performed with independent samples t-test. (${\alpha}=0.05$). Results: Mean(SD) of all internal fitness were $92.1(20.0){\mu}m$ for AM group and $69.7(12.3){\mu}m$ for CM group. Two groups were statistically significant differences (p<0.001). Conclusion: All internal gaps of AM group were ranged within the clinical recommendation ($120{\ss}{\neq}$).

L-PBF 공정 처리된 Fe-Si 합금의 열처리 조건에 따른 미세조직 및 기계적 특성 (Mechanical Property and Microstructure of the Annealed Fe-Si Alloy Manufactured by Laser-Powder Bed Fusion)

  • 박준영;곽민석;정상국;김형섭;김정기
    • 소성∙가공
    • /
    • 제32권2호
    • /
    • pp.67-73
    • /
    • 2023
  • To overcome a climate change, manufacturing complex-shaped electric mobility parts becomes one of the important issues for enhancing a performance of motor with reducing their weight. Therefore, development of laser-based additive manufacturing shed on light due to their flexible manufacturing capacity that can be suitable to solve the poor formability of Fe-Si alloys for electric mobility parts. Although there are several studies existed to optimize the performance of additively manufactured Fe-Si alloys, the post-annealing effect was not well investigated yet though this is important to control the texture and mechanical properties of additively manufactured parts. In the present work, annealing effect on the mechanical property and microstructure of additively manufactured Fe-4.5Si alloy was investigated. Because of the ordered phase initiation after annealing, the hardness of additively manufactured Fe-4.5Si alloy increased up to 1173 K while a hardness drop occurs at the 1273 K condition due to the micro-crack initiation. The response surface methodology result represents the 1173 K-5 h sample is an optimal condition to maximize the mechanical property of additively manufactured alloy without micro-cracks.

적층공법을 적용한 시멘트계 복합재료의 수축특성 (Shrinkage Characteristic of Cementitious Composite Materials for Additive Manufacturing)

  • 이호재;김기훈;유병현;김원우;문재흠
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.99-104
    • /
    • 2019
  • 본 연구의 목적은 시멘트계 복합재료의 적층을 위해 증점제를 적용하여 개발한 출력배합의 수축 특성을 평가하고, 프린팅 기법을 이용해 제작한 적층시험체와의 수축 특성을 비교하는 데 있다. 증점제 적용 시 수축이 기준배합과 비교하여 평균 25% 저감(56일 기준)되는 것을 확인하였다. 수축이 저감되는 긍정적인 효과에 반해 압축강도는 약 15% 감소(28일 기준)되는 부정적인 효과도 확인되었다. 출력배합을 이용해 제작한 적층시험체와 몰드시험체를 이용하여 수축을 평가한 결과, 적층시험체의 수축변형률이 약 25% 감소(28일 기준)되는 것을 확인하였다. 본 연구결과를 통해 3D 프린팅을 이용한 시멘트계 복합재료의 출력 시 수축의 진전속도와 수축으로 인한 균열의 발생시점을 예측할 수 있을 것으로 판단된다.

적층가공 방식으로 제조된 CP-Ti의 캐비테이션 중 부식에 대한 전기화학적 접근 (Electrochemical Approach on the Corrosion During the Cavitation of Additive Manufactured Commercially Pure Titanium)

  • 김기태;장현영;김영식
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.310-316
    • /
    • 2018
  • The effect of passive film on corrosion of metals and alloys in a static corrosive environment has been studied by many researchers and is well known, however few studies have been conducted on the electrochemical measurement of metals and alloys during cavitation corrosion conditions, and there are no test standards for electrochemical measurements 'During cavitation' conditions. This study used commercially additive manufactured(AM) pure titanium in tests of anodic polarization, corrosion potential measurements, AC impedance measurements, and repassivation. Tests were performed in 3.5% NaCl solution under three conditions, 'No cavitation', 'After cavitation', and 'During cavitation' condition. When cavitation corrosion occurred, the passive current density was greatly increased, the corrosion potential largely lowered, and the passive film revealed a small polarization resistance. The current fluctuation by the passivation and repassivation phenomena was measured first, and this behavior was repeatedly generated at a very high speed. The electrochemical corrosion mechanism that occurred during cavitation corrosion was based on result of the electrochemical properties 'No cavitation', 'After cavitation', and 'During cavitation' conditions.

Enhancement of critical heat flux with additive-manufactured heat-transfer surface

  • Tatsuya Kano;Rintaro Ono;Masahiro Furuya
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2474-2479
    • /
    • 2024
  • In-Vessel Retention (IVR) is a key technology to retain the molten core in the reactor vessel during severe accidents of Pressurized-water reactors (PWRs). In order to gain the safety margin of IVR, it is crucial to enhance the critical heat flux (CHF) of the reactor vessel, which is submerged in a water pool. To enhance the CHF, we have designed and additive-manufactured porous grid plates with a 3-D printer for design flexibility. We measured the CHF for the porous grid plate on the boiling heat transfer surface and found that the CHF was enhanced by 50 % more than that of the bare surface. The CHF enhanced more with a narrower grid pitch and a lower grid height. The visual observation study revealed that the vapor film was formed at the bottom of the grid plate.