• Title/Summary/Keyword: addition tests

Search Result 3,865, Processing Time 0.035 seconds

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

Acute and Chronic Toxicity of heavy Metals to Daphnia magna (물벼룩(Daphnia magna)에 대한 중금속의 급성 및 만성 독성)

  • Jeong, Jae-Won;Cha, Mi-Seon;Jo, Sun-Ja;Lee, Sang-Jun
    • Journal of Environmental Science International
    • /
    • v.10 no.4
    • /
    • pp.293-298
    • /
    • 2001
  • The toxicity values heavy metals were evaluated by immobilization and chronic reproduction impairment tests, using Daphnia magna. Acute tests were evaluated by the inhibition of their mobilization after 24hrs without food addition. The tests of reproductive impairment were investigated for 21 days by food addition and exchange or water. The effect of each concentration was assessed by Probit analysis and t-test. The results obtained from this study were as follows : 1) The change of pH and DO was not significant in the acute tests, while, in the reproductive tests, pH was increased by 0.3~1.4 and DO also increased. 2) The $E_iC_{50}$ values of immobilization to Daphnia magna in artificial fresh water were $0.030mg/{\ell}(Cu),\;0.054mg/{\ell}(Cd),\;0.12mg/{\ell};(Cr),\;0.74mg/{\ell}(Pb),\;3.4mg/ {\ell}(As)$ and the $NOE_iC$ values were $0.010mg/{\ell}(Cu),\;0.018mg/{\ell}(Cd),\;0.010mg/{\ell}(Cr),\;0.10mg/{\ell}(Pb),\;and\;$1.8mg/{\ell}(As)$. 3) The $E_rC_{50}$ values of reproductive impairment to Daphnia magna were $13.8\mu\textrm{g}/{\ell}(Cu),\;2.9\mu\textrm{g}/{\ell}(Cd),\;15.5\mu\textrm{g}/{\ell}(Cr),\;61.7\mu\textrm{g}/{\ell}(Pb),\;759\mu\textrm{g}/{\ell}(As)$, and $NOE_rC$ values were $0.95\mu\textrm{g}/{\ell}(Cu),\;$0.54\mu\textrm{g}/{\ell}(Cd),\;1.2\mu\textrm{g}/{\ell}(Cd),\;$7.4\mu\textrm{g}/{\ell}(Pb),\;110mu\textrm{g}/{\ell}(As)$. The results of tests using OECD artificial culture water were more sensitive than natural water for culturing. The presented data show that an artificial culture water is suitable in the experiment of bioassay for assessing the toxicity of marterials.

  • PDF

Statistical tests for biosimilarity based on relative distance between follow-on biologics for ordinal endpoints

  • Yoo, Myung Soo;Kim, Donguk
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Investigations of biosimilarity between reference drugs and test drugs required statistical tests; in addition, statistical tests to evaluate biosimilarity have been recently proposed. Ordinal outcome data has been observed in research; however, appropriate statistical tests to deal with ordinal endpoints for biosimilar have not yet been proposed. This paper extends existing design for ordinal endpoints. Using measure of nominal-ordinal association and relative distances between drugs are defined so that testing procedures are developed. Through simulation studies, we investigate type I error rate and power to show the performance of our suggested method. Furthermore, a comparison between the statistical tests and other designs is proviede to show significance of ordinal endpoints.

Future of Toxicology and Role of Asian Chemical Safety Network

  • Kaminuma, Tsuguchika
    • Toxicological Research
    • /
    • v.17
    • /
    • pp.241-249
    • /
    • 2001
  • Toxicology is under challenge from several new trends in science and technology, namely computer, the Internet, genome projects, genomic technologies, and combinatorial chemistry. These new trends will drastically change research style of toxicology. In addition to conventional uni cellular tests and animal tests using rodents, computer simulation, DNA chips (microarrays), in vivo tests using simple model organisms such as nematodesor flies become important routine screening tests. How to arrange these tests in tiers will become a new problem. Endocrine disruptors hypothesis is a good example for this kind of futuristic approach. Computer, particularly the Internet, is also enabling toxicologists and regulatory experts to collaborate more closely. The IPCS (International Program for Chemical Safety) which is ajoint project of WHO, ILO and UNEP, is a well-known international collaborative research for chemical risk assessments. The GINC project of IPCS is an effort to utilize the Internet for such collaborations. Some efforts were also made to establish regional collaboration network in East Asia under this project.

  • PDF

Correlation between Component Fatigue Performance and Results from Plane Bending Fatigue Tests on Notched Samples

  • Bergmark, Anders;Dizdar, Senad;Bengtsson, Sven;Luk, Sydney
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.381-382
    • /
    • 2006
  • A comparative study is made on root bending fatigue performance of spur gears and plane bending fatigue performance of notched test bars. R = 0 root bending fatigue tests are made on small spur gears with critical root radius 1.0 mm. The results are compared to plane bending fatigue tests of 0.9 mm radius notched specimens. Results are presented for tests on 4%Ni/2%Cu/1.5%Mo prealloyed PM steel with addition of about 0.6% graphite. Predicted values from the test bars coincide well with the results obtained from the gear root fatigue tests.

  • PDF

A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size (다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가)

  • Jung, Jong-Wook;Kim, Sun-Gu;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

Effects of Inlet-Manifold Water Addition on the Performance of Kerosene Engines (석유(石油)엔진의 흡기관내(吸氣管內)의 물 부가(附加)가 엔진성능(性能)에 미치는 영향(影響))

  • Yi, Chun Woo;Ryu, Kwan Hee
    • Journal of Biosystems Engineering
    • /
    • v.8 no.1
    • /
    • pp.38-46
    • /
    • 1983
  • This study was carried out to investigate the possibility of improving the performance of a kerosene engine with water addition. The engine used in this study was a single-cylinder, four-cycle kerosene engine with the compression ratio of 4.5. Water could be successfully added into the inlet manifold by an extra carburetor for the volumetric ratios of 5, 10, 20, and 30 percents. Variable speed tests at wide-open throttle were performed for five speed levels in the range of 1,000 to 2,200rpm for each fuel type. Volumetric efficiency and brake specific fuel consumption were determined, and brake thermal efficiency based on the lower heats of combustion of kerosene was calculated. To examine variation in fuel consumption, CO concentration, and cooling water temperature, part load tests were also performed. The results obtained are summarized as follow. (1) Brake torque increased almost in proportion to volumetric efficiency. But the ratio of increase in torque was greater than that of volumetric efficiency. Mean torque over the speed range of 1,000 to 2,200rpm increased 1, 3, 7, and 2 percents for 5, 10, 20, and 30 percents water addition, respectively. The increase in brake torque with water addition was greater at lower speeds. (2) Mean brake specific fuel consumption over the speed range of 1,000 to 2,200rpm decreased 1, 2, 3, and 3 percents for 5, 10, 20, and 30 percents water addition, respectively. (3) Mean temperature of cooling water over the speed range of 1,000 to 2,200rpm decreased 2, 4, 8, and 12 percents for 5, 10, 20, and 30 percents water addition, respectively. (4) The effects of decreasing CO concentration in the exhaust emissions with water addition were significant. At the speed range of 1,000 to 2,200rpm, CO concentration in the exhaust emissions decreased 2, 10, 23, percents for 5, 10, and 20 percents water addition, respectively. (5) Deposits were not discovered in the combustion chamber during the experiment. However, a little rust was formed in the water-supply carburetor.

  • PDF

Biocontrol of Phytophthora Blight and Anthracnose in Pepper by Sequentially Selected Antagonistic Rhizobacteria against Phytophthora capsici

  • Sang, Mee Kyung;Shrestha, Anupama;Kim, Du-Yeon;Park, Kyungseok;Pak, Chun Ho;Kim, Ki Deok
    • The Plant Pathology Journal
    • /
    • v.29 no.2
    • /
    • pp.154-167
    • /
    • 2013
  • We previously developed a sequential screening procedure to select antagonistic bacterial strains against Phytophthora capsici in pepper plants. In this study, we used a modified screening procedure to select effective biocontrol strains against P. capsici; we evaluated the effect of selected strains on Phytophthora blight and anthracnose occurrence and fruit yield in pepper plants under field and plastic house conditions from 2007 to 2009. We selected four potential biocontrol strains (Pseudomonas otitidis YJR27, P. putida YJR92, Tsukamurella tyrosinosolvens YJR102, and Novosphingobium capsulatum YJR107) among 239 bacterial strains. In the 3-year field tests, all the selected strains significantly (P < 0.05) reduced Phytophthora blight without influencing rhizosphere microbial populations; they showed similar or better levels of disease suppressions than in metalaxyl treatment in the 2007 and 2009 tests, but not in the 2008 test. In the 2-year plastic house tests, all the selected strains significantly (P < 0.05) reduced anthracnose incidence in at least one of the test years, but their biocontrol activities were variable. In addition, strains YJR27, YJR92, and YJR102, in certain harvests, increased pepper fruit numbers in field tests and red fruit weights in plastic house tests. Taken together, these results indicate that the screening procedure is rapid and reliable for the selection of potential biocontrol strains against P. capsici in pepper plants. In addition, these selected strains exhibited biocontrol activities against anthracnose, and some of the strains showed plant growth-promotion activities on pepper fruit.

Evaluation of failure mode of tunnel-type anchorage for a suspension bridge via scaled model tests and image processing

  • Seo, Seunghwan;Lim, Hyungsung;Chung, Moonkyung
    • Geomechanics and Engineering
    • /
    • v.24 no.5
    • /
    • pp.457-470
    • /
    • 2021
  • In this study, the pull-out behavior of a tunnel-type anchorage for suspension bridges was investigated using experimental tests and image processing analyses. The study focused on evaluating the initial failure behavior and failure mode of the tunnel-type anchorage. In order to evaluate the failure mode of tunnel-type anchorage, a series of scaled model tests were conducted based on the prototype anchorage of the Ulsan Grand Bridge. In the model tests, the anchorage body and surrounding rocks were fabricated using a gypsum mixture. The pull-out behavior was investigated under plane strain conditions. The results of the model tests demonstrate that the tunnel-type anchorage underwent a wedge-shaped failure. In addition, the failure mode changed according to the differences in the physical properties of the surrounding rock and the anchorage body and the size of the anchor plate. The size of the anchor plate was found to be an important parameter that determines the failure mode. However, the difference in physical properties between the surrounding rock and the anchorage body did not affect its size. In addition, this study analyzed the initial failure behavior of the tunnel-type anchorage through image analysis and confirmed that the failure was sequentially transferred from the inside of the tunnel to the surrounding rock according to the image analysis. The reasonable failure mode for the design of the tunnel-type anchorage should be wedge-type rather than pull-out type.

Applying to simulation analysis for predicting the combustion performance of Large scale fire tests (실대화재시험의 연소성능 예측을 위한 시뮬레이션 적용)

  • Kim, Woon-Hyung;Park, Kye-Won;Jeong, Jae-Gun;Im, Hong-Soon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.86-92
    • /
    • 2008
  • On this study, modeling works using Cone tools simulation method were made for the prediction of real fire test results such as small to large scale fire tests including ISO 5660-1, EN 13823 and ISO 13784-1. For those simulation prediction, three real fire tests were performed in advance. In addition, Real data from ISO 5660-1 test were applied to this simulation modeling. Finally, the comparative analysis between Real fire tests and Simulation results were made out. Also, the Classifying evaluation by EURO Class using EN 13501-1 were taken off.

  • PDF