• Title/Summary/Keyword: add-on kit

Search Result 6, Processing Time 0.032 seconds

Numerical investigation of an add-on thrust vector control kit

  • AbuElkhier, Mohamed G.;Shaaban, Sameh;Ahmed, Mahmoud Y.M.
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.1
    • /
    • pp.39-57
    • /
    • 2022
  • Instead of developing new guided missiles, converting unguided missile into guided ones by adding guidance and controlkits hasbecome aglobaltrend.Ofthemost efficient andwidelyused thrust vector control(TVC) techniquesin rocketry isthe jet vanes placed inside the nozzle divergentsection. Upon deflecting them, lift created on the vanesistransferred to the rocket generating the desired control moment. The presentstudy examinesthe concept of using an add-on jet vaneTVC kit to a plain nozzle.The impact of adding the kit with different vaneslocations and deflectionanglesisnumericallyinvestigatedbysimulatingtheflowthroughthenozzlewiththekit.Twohingelocations are examined namely, at 24% and 36% of nozzle exit diameter. For each location, angles of deflection namely 0°, 5°, 10°, and 15° are examined. Focus is made on variation of control force, thrust losses, lift and drag on vanes, jet inclination, and jetflow structure withTVCkit design parameters.

A Development of Pivoting Composite Wing for Mounting Kit (키트용 접이식 복합재 날개 개발)

  • Joo, Young-Sik;Jun, Woo-Chul;Byun, Kwan-Hwa;Cho, Chang-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.486-492
    • /
    • 2013
  • The pivoting composite wing is developed for the kit to be mounted on the external stores. The wing has a pivoting structure for the installation to an aircraft and high aspect ratio to increase lift drag ratio. The wing needs to be light and have sufficient strength and stiffness to satisfy structural design requirements. The wing is designed with carbon fiber composite and the structural parts are integrated to reduce cost to manufacture. In order to verify the structural performances, the design load analysis and flight load survey, the static analysis and test, the ground vibration test and flutter analysis are performed. It is shown that the wing has sufficient structural strength and stiffness to satisfy the structural design requirements.

Porting and Implementation of a 3D Cube Game using Android NDK(Native Development Kit) (안드로이드 NDK(Native Development Kit)를 이용한 3D 큐브 게임 이식 및 구현)

  • Koh, Eunbyul;Kim, Nokhee;Hwang, Sungmi;Lee, Jongwoo
    • Journal of Digital Contents Society
    • /
    • v.14 no.3
    • /
    • pp.381-390
    • /
    • 2013
  • Almost all the mobile phone users already moved or are now moving away to smartphones for their various applications like games. If we are to speak about game applications, due to the performance limits of smartphones, 2D games are predominant over 3D games in every app. store. In this paper, we implement a 3D cube game application by porting an existing visual c++ irrlicht cube application to android platform library using the android Native Development Kit. After the porting is done, we add a few new features for more fun. Because the android NDK makes the existing C/C++ codes run directly on the android operating systems, we found by real execution tests that our 3D cube app. is well executed on a low-end android smartphone without any performance problem.

Mutagenecity Test of SDK (SDK시제품(가칭)에 대한 변이원성시험)

  • 정지윤;이원우;임종희;남정석;제정환;이광훈;강병철;이병희;박재학
    • Toxicological Research
    • /
    • v.14 no.2
    • /
    • pp.211-216
    • /
    • 1998
  • In order to evaluate the mutagenic potential of SDK(skin decontamination kit) produced by Agency for Defense Development(ADD), were performed Salmonella typhimurium reversion assay, chromosomal aberration test on chinese hamster ovarian cells and in vivo micronucleus assay using mouse bone marrow cells according to the established regulation of Korean Food and Drug Administration. In the reverse mutation test using Salmonella typhimurium TA98, TA100, TA1535 and TA1537 did not in-crease the number of revertant at any of the concentration tested in this study. SDK did not increase the number of cells having structural or numerical chromosome aberration in cytogenetic test. In mouse micronucleus test, no significant increase in the occurrence oj micro nucleated polychromatic erythrocytes were observed in ICR male mice intraperitoneally administered with SDK. These results indicate that SDK has no mutagenic effects under these experimental conditions.

  • PDF

Usability of CPR Training System based on Extended Reality (확장현실 기반의 심폐소생술 교육 시스템의 사용성 평가)

  • Lee, Youngho;Kim, Sun Kyung;Choi, Jongmyung;Park, Gun Woo;Go, Younghye
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.6
    • /
    • pp.115-122
    • /
    • 2022
  • Recently, the importance of CPR training for the layperson has been emphasized to improve the survival rate of out-of-hospital cardiac arrest patients. An accurate and realistic training strategy is required for the CPR training effect for laypersons. In this study, we develop an extended reality (XR) based CPR training system and evaluate its usability. The XR based CPR training system consisted of three applications. First, a 3D heart anatomy image registered to the manikin is transmitted to the smart glasses to guide the chest compression point. The second application provides visual and auditory information about the CPR process through smart glasses. At the same time, the smartwatch sends a vibration notification to guide the compression rate. The 'Add-on-kit' is a device that detects the depth and speed of chest compression via sensors installed on the manikin and sends immediate feedback to the smartphone. One hundred laypersons who participated in this study agreed that the XR based CPR training system has realism and effectiveness. XR based registration technology will contribute to improving the efficiency of CPR training by enhancing realism, immersion, and self-directed learning.

The Significance of Acetylcholine Receptor Autoantibody Test (아세틸콜린 수용체 항체(Acetylcholine receptor autoantibody) 검사의 의의)

  • Yoo, Soh-Yeon;Lim, Soo-Yeon;Pack, Song-Ran;Seo, Mi-Hye;Moon, Hyung-Ho;You, Sun-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.113-116
    • /
    • 2011
  • Purpose: Acetylcholine receptor antibodies cause acetylcholine receptor loss, which is responsible for failure of the neuromuscular junction in the acetylcholine receptor autoantibody. The disease characterized by muscle weakness and fatigue, myasthenia gravis(MG) occurs when the body inappropriately produces antibodies against acetylcholine receptors, and thus inhibits proper acetylcholine signal transmission. And this reason, the measurement of acetylcholine receptor antibodies can be of considerable value in disease diagnosis. Methods: From 2010. August to September, we tested orderd AchRAb 19 samples to get the results. 1. Pipette $5{\mu}{\ell}$ undiluted patient sera and kit control and add 125I AChR $50{\mu}{\ell}$ and incubate at R.T for 2 hours. 2. Pipette $50{\mu}{\ell}$ of anti-human IgG into each tube, and incubate at $2{\sim}8^{\circ}C$ for 2 hours. 3. Pipette $25{\mu}{\ell}$ precipitation enhancer into each tube and add 1mL washing solution into all tubes. 4. Centrifuge each tube for 20minutes at $2{\sim}8^{\circ}C$ at 1500g. 5. Aspirate or decant the supernatant. 6. Pipette 1 mL washing solution into all tubes and resuspend the pellet and repeat centrifugation. 7. Aspirate or decant the supernatant and count all tubes on a gamma counter. Results: Cut off value is 0.2 nmol/L and the results taken below 0.2 nmol/L are negative, the results above that identified as being positive values. We assayed the 19 patients samples and got 7 positive results. Of which, 6 patients were diagnosed as MG.(85.7%). Conclusions: Acetylcholine Receptor autoantibody test is intended for use by persons only for the quantitative determination of it in human serum. Even if measurement of the antibodies is not a routine test, it can be of considerable value in disease diagnosis.

  • PDF