• Title/Summary/Keyword: active pressure

Search Result 959, Processing Time 0.024 seconds

An Electro-magnetic Air Spring for Vibration Control in Semiconductor Manufacturing (반도체 생산에서 진동 제어를 위한 전자기 에어 스프링)

  • Kim, Hyung-Tae;Kim, Cheol-Ho;Lee, Kang-Won;Lee, Gyu-Seop;Son, Sung-Wan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1128-1138
    • /
    • 2010
  • One of the typical problems in the precise vibration is resonance characteristics at low frequency disturbance due to a heavy mass. An electro-magnetic(EM) air spring is a kind of vibration control unit and active isolator. The EM air spring in this study aims at removing the low frequency resonance for semiconductor manufacturing. The mechanical and electronic parts in the active isolator are designed to operate under a weight of 2.5 tons. The EM spring is floated using air pressure in a pneumatic elastic chamber and actuated by EM levitation force. The actuator consists of a EM coil and a permanent magnetic plate which are installed inside of the chamber. An air mount was constructed for the experiment with a stone surface plate, 4 active air springs, 4 gap sensors, a DSP controller, and a multi-channel power amp. A PD control method and operating logic was applied to the DSP. Simulation using 1/4 model was carried out and compared with the experiments. The time duration and maximum peak at resonance frequency can be reduced sharply by the proposed system. The results show that the active system can avoid the resonance caused by the natural frequency of the passive system.

Crown removal and endodontic drainage as a last method in active gingival bleeding with liver cirrhosis and periodontitis: a case report (간경화증과 치주염으로 과도한 치은출혈을 보인 응급환자에서 최후 지혈방법으로 치관제거와 치근관 배농술: 증례보고)

  • Choi, Young-Su;Kang, Sang-Hoon;Kim, Moon-Key;Lee, Chun-Ui;Yoo, Jae-Ha
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.3
    • /
    • pp.221-227
    • /
    • 2010
  • The most common local cause of active gingival bleeding is the vessel engorgement and erosion by severe inflammation. Abnormal gingival bleeding is also associated with the systemic disturbances. Hemorrhagic disorders in which abnormal gingival bleeding is encountered include the following: vascular abnormalities (vitamin C deficiency or allergy), platelet disorders, hypoprothrombinemia (vitamin K deficiency resulting from liver disease), and other coagulation defects (hemophilia, leukemia). There are many conventional methods for gingival bleeding control, such as, direct pressure, electrocoagulation, direct suture, drainage, application of hemostatic agents and crushing and packing. If the active continuous gingival bleeding is not stopped in spite of the application of all conventional bleeding control methods, the life of patient is threatened owing to upper airway obstruction, syncope, vomiting and hypovolemic shock. Therefore, the rapid and correct hemostatic method is very important in the emergency dental care. This is a case report of active gingival bleeding care via dental crown removal and emergency primary endodontic drainage as a last method in liver cirrhosis patient with advanced periodontitis.

The Active Fault Topography of the Northern Partof the Bulguksa Fault System in Kyungju City, Southeastern Korea (한국 남동부 청주시 불국사단층선 북부의 활단층지형)

  • 윤순옥;황상일
    • Journal of the Korean Geographical Society
    • /
    • v.34 no.3
    • /
    • pp.231-246
    • /
    • 1999
  • The geomorphic deformation of the alluvial fans by tectonic movement was investigated along the lineaments of the northern part of the Bulguksa fault system. Based on the aerial photographs interpretation and field surveys Bulguksa fault system was identified as an active reverse fault which has displaced the Quaternary fan deposits. Bulguksa fault system strikes for the direction of NW-SE and N-S. These two lineaments of active fault are crossing at Jinty village in Kyungju city and the fault plane forms here almost vertical dip. Thelateral pressures from the two directions have possibly influenced on the formation of the vertical dip at Jinty village. It should be resulted from that the two pressures responsible for the active reverse fault at which the one with the NW-SE strike thrusts the hanging wall of Tohamsan block southwestward and the other pressure with the N-S jstrike thrusts it westwrd over the foot wall of the fan deposits. The marine oxygen isotope stage 8(0.30-0.25 Ma. BP) and stage 6(0.20-0.14 Ma. BP) are presumed to be the ages of high and middle surfaces of the alluvial fan, repectively. The vertical dispiacements on the high surface along the Bulguksa fault system are about 10.5m at Ha-dong, 9.5-10.5m at Jinhyun-dong, and about 10m at Jinty village. And the vertical displacement on the middle surface was measured about 6m high at Ha-dong. The average slip rate of vertical displacements is calculated about 0.03-0.043mm/y.

  • PDF

A Study on Weight Control Behavior by Female Consumers Eating Life Styles (여성 소비자의 식생활 라이프스타일에 따른 체중 조절 행위에 관한 연구)

  • Han, In-Kyung;Ha, Ae-Wha
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.2
    • /
    • pp.177-184
    • /
    • 2009
  • The study investigated the eating lifestyles of female consumers and whether they influenced weight control behavior. The findings of the study can be summarized as follows. First, the eating lifestyles of the subjects were presented four types: 'active eating life pursuit type', 'safe economical type', 'gourmet type' and 'passive negligence type'. In general, most cases were of the 'passive negligence type'. Second, weight control behavior was analyzed according to eating lifestyle. The results of the analysis indicated that the female consumers of the 'active eating life pursuit type' and 'safe economy type' had high behavior levels in each aspect of weight control attitude, subjective regulation, perceived behavior control, and behavior intention. Third, the 'gourmet type', with a strong preference for taste, and the 'passive negligence type', with fewer eating considerations in general, showed weaker attitudes towards weight control and the recognition of pressure from people around them. As such, the level of consideration for food or eating was correlated with weight control. These findings impliedy that the more active, safer, and economical women are in their general eating style, the stronger they perceive weight control issues.

Active Control of Noise Propagated through Ventilation Openings of Enclosures Using an FIR Filter (FIR 필터를 이용한 인클로저 환기구를 통해 투과되는 소음의 능동제어)

  • Ji, Sumin;Hong, Chinsuk;Jeong, Weui-Bong;Kim, Tae-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.3
    • /
    • pp.191-198
    • /
    • 2015
  • Noise propagated through the ventilation openings of enclosures is actively controlled using an FIR filter. The enclosures considered in this paper are used for isolating noise due to machinery. This method is of limited use because of the ventilation openings through which most of noise is propagated. Feedforward control strategy is incorporated to minimize the acoustic power propagated through the openings. For the real-time implementation, although it is numerical study, the controller is implemented using an FIR filter. The acoustic transfer functions of the pressure on the openings of the enclosure to the primary source and to the secondary source are numerically calculated using the boundary element method. The performance analysis of the active control is conducted with the time-domain simulation using Matlab Simulink.

Forward Osmosis Based Seawater Desalination using Liquid Fertilizer as Draw Solution (액상 비료를 유도 용액으로 사용하는 정삼투 기반의 해수 담수화)

  • Park, Seong-Jik;An, Hee-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.21-27
    • /
    • 2013
  • The present study explored the way to desalinate seawater for agricultural irrigation using forward osmosis (FO) process using liquid fertilizer as draw solution. FO experiments were performed in a cross flow mode using flat sheet FO membrane. The effect of membrane orientation, flow rate, and draw solution concentration on the performance of forward osmosis was investigated by measuring water flux of forward osmosis membrane. The water flux when the draw solution was placed against the membrane active layer was lower than the water flux when the feed solution was placed against the membrane active layer. This results indicated that the decrease of effective osmotic pressure by dilutive internal concentration polarization was less than that by concentrative internal concentration polarization. Increasing flow rate from 66.7 to 133.1 $cm^3$/min resulted in increase of the water flux when the membrane active layer orient to draw solution and feed solution, respectively. The reduction of resistance to water flow increased water flux at higher flow rate. The water flux of FO membrane increased with increasing draw solution concentration from 10000 to 30000 mg/L. The water flux for $KH_2PO_4$ draw solution was similar to that for commercial fertilizer. Optimization of FO process would contribute to economically desalinate brackish water for agricultural use.

The Effect of Exhaust Performance by according to Active Muffler Valve Spring (능동형 소음기의 밸브 스프링이 배기 성능에 미치는 영향)

  • Kong, T.W.;Yi, C.S.;Chung, H.S.;Jeong, H.M.;Suh, J.S.;Chun, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.682-687
    • /
    • 2001
  • This study represents effect of exhaust performance by according to active muffler valve spring. The experimental parameter were divided engine speed and torsion coil spring constant. The sound pressure level was generally low at engine speed 2000-2500rpm but That was showed the lowest at spring constant k=0.75. Flow speed of exhaust gas was showed the fast at spring constant k=0.75 but the low value was showed at k=0.97. It was contained a rather low concentration of carbon monoxide(CO) at engine speed 2000-2500rpm and k=0.81, low concentration of hydrocarbon(HC) at spring constant k=0.81 but that was high at spring constant k=0.97. A conclusion based on FFT analysis was generally low concentration value at k=0.79 and k=0.81. The temperature distributions into the muffler was shown similar conditions. Heat transfer was well spreaded at thermocouple No.8 because valve was opened.

  • PDF

Self-Tuning Gain-Scheduled Skyhook Control for Semi-Active Suspension Systems: Implementation and Experiment (반능동 현가시스템용 자기동조 게인조절형 스카이훅 제어기의 구현 및 실험)

  • Hong, Kyung-Tae;Huh, Chang-Do;Hong, Keum-Shik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.3
    • /
    • pp.199-207
    • /
    • 2002
  • In this paper, a self-tuning gain-scheduled skyhook control for semi-active suspension systems is investigated. The dynamic characteristics of a continuously variable damper including electro-hydraulic pressure control valves is analyzed. A 2-d.o.f. time-varying quarter-car model that permits variations in sprung mass and suspension spring coefficient is considered. The self-tuning skyhook control algorithm proposed in this paper requires only the measurement of body acceleration. The absolute velocity of the sprung mass and the relative velocity of the suspension deflection are estimated by using integral filters. The skyhook gains are gain-scheduled in such a way that the body acceleration and the dynamic tire force are optimized. An ECU prototype is discussed. Experimental results using a 1/4-ear simulator are discussed. Also, a suspension ECU prototype targeting real implementation is provided.

Effects of Captopril on the Active Angiotensin Converting Enzyme at the Pulmonary Endothelial Cells (Captopril에 의한 폐동맥 내피세포중 활성형 Angiotensin 전환효소의 변화)

  • 안형수
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.41-48
    • /
    • 1993
  • The effect of captopril on the lung angiotensin converting enzyme (ACE) was investigated after 3 weeks oral administration (120~160 mg/kg/day) through drinking water in SpragueDawley rats. On the $^{125}$I-351A, an ACE inhibitor, binding assay in the isolated perpused lungs, the number of ACE molecules at the intrapulmonary endothelial cell surface was significantly decreased (p<0.001), and recovered to the normal level 7 days after discontinuation of captopril treatment. Intrapulmonary conversion ratio of Al to All was also significantly decreased (p<0.05) in the isolated perpused lungs. Bolus intravenous injection of angiotensin I did not showed pressor response in the both of systemic and pulmonary blood pressure of the anesthetized rats. ACE activity of the lung homogenates was also significantly reduced. These data consistently indicate the decrease of functionally active ACE molecule at the pulmonary artery after chronic captopril treatment. However, serum ACE activity was increased three fold in captopril treated rats compared to the normal rats. So, these results suggest that the functionally active ACE molecule at the pulmonary artery was still inhibited, which is directly associated with the antihypertensive effects, even if the total angiotensn converting enzyme induction was resulted after chronic captopril treatment.

  • PDF

Active Noise Control for Target Point Inside Bore Using Property of MRI Noise (MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어)

  • Lee, Nokhaeng;Park, Youngjin;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.