• Title/Summary/Keyword: active power filter

Search Result 580, Processing Time 0.029 seconds

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

A Shunt HBML Active Power Filter for Damping of Voltage Harmonics Propagation in Power Distribution System (장거리 배전선로의 전압 고조파 확산 억제를 위한 병렬형 HBML능동전력필터)

  • Oh, Seung-Yeol;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.462-465
    • /
    • 2008
  • 본 연구에서는 장거리 배전선로의 전압 고조파 확산을 억제하기 위한 HBML 능동전력필터(HBML-AFU : H-Bridge Multi-Level Active Power Filter Unit)를 제시하였다. 버스(Bus)의 전압 고조파는 60Hz 버터워쓰 대역통과필터(BPF : Band Pass Filter)에 의하여 검출하였다. 제안된 시스템의 보상전원으로는 배터리($24v{\times}2=48v$)를 사용하였다. 제안된 시스템의 타당성은 PSIM시뮬레이션에 의하여 과도상태 및 정상상태에서 확인하였다.

  • PDF

Design of Improved Active Power Filter using Discrete Variable Structure Control (DVSC를 이용한 개선된 APF의 설계)

  • Park, Hae-Won;Kim, Sang-Woo;Han, Wun-Dong;Kim, Beung-Jin;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1312-1314
    • /
    • 2000
  • In this paper, voltage control APF(Active Power Filter) is introduced to improve power factor and reduce harmonic, generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. According to the results of simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF

A simple method to optimize DC-bus capacitor in 3-phase shunt Active power filter system

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.367-368
    • /
    • 2015
  • This paper introduces a shunt active power filter with a small DC bus capacitor by adding additional low-pass filter (LPF). The DC link voltage fluctuation is impressively suppressed with a small value in spite of the low value of DC-link capacitor under the steady-state condition. Consequently, the cost and volume of power converter are significantly reduced thanks to the reduced value of DC-bus capacitor. On the other hand, an indirect control strategy is used to maintain grid-side current when non-linear loads are connected to the system. By using proportional-integral (PI) and modified repetitive controller (RC) in dq0 frame, the calculation time is greatly decreased by 6 times compared with the conventional RC, and the number of measurement devices is also minimized. As a result, the acquired total harmonic distortion (THD) is lower than 2% regardless of the load conditions. Simulation results are carried out in order to verify the effectiveness of the proposed control strategy.

  • PDF

A Study on Series Arc Detection Using Band-pass Filters (대역통과필터를 이용한 직렬아크 검출에 관한 연구)

  • Kim, Il-Kwon;Kim, Jin-Su;Park, Keon-Woo;Kim, Kwang-Soon;Kim, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1345-1347
    • /
    • 2008
  • This paper described a method of determining whether arcing is present in a low-voltage wiring system. We simulated the series arcing that generated in electrical loads and fabricated a arc detection module which can discriminate between normal and arcing state. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage and an active band-pass filter with a frequency of 4 kHz ${\sim}$ 8 kHz to detect series arc signals only. We tested an Incandescent lamp that was controlled by a dimmer and analysed. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. From the experimental results, we could detect series arc signals without an influence of non-linear loads.

  • PDF

The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads (비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현)

  • Jang, Mok-Soon;Lee, Hu-Chan;Kim, Sang-Hoon;Park, Jong-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

Simulator Development for Evaluating Compensation Performance. of Active Power Filter using Three-Dimensional Space Current Co-ordinate (3차원(次元) 전류좌표(電流座標)에 의한 능동전력(能動電力)필터의 보상성능(補償性能) 평가(評價)를 위한 시뮬레이터 개발(開發))

  • Lim, Young-Choel;Jung, Young-Gook;Na, Suk-Hwan;Choi, Chan-Hak;Chang, Young-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.337-341
    • /
    • 1994
  • This paper describes an effort to develop a simulator of Active Power Filter (APF) by three dimentional(3-D) space current co-ordinate. System current is represented by 3-D vector composed of three current components - active, reactive and distorted. %THD (%Total Harmonics Distortion) can be converted to height-angle of system current vector and power factor can be defined on 3-D space current co-ordinate without loss of generality. Current of APF and power system can be analyzed by 3-D visualization of current vector trajectory. So, the computer simulation results show that the proposed method by 3-D space current co-ordinate make up for disadvantages of performance evaluation on time / frequency domain.

  • PDF

Power Quality Improvement of an Electric Arc Furnace Using a New Universal Compensating System

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein;Ali Yazdian-Varjani
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.195-204
    • /
    • 2006
  • This paper presents a new compensating system, consisting of series and shunt active filters, for mitigating voltage and current disturbances. The shunt filter is used to compensate for unbalanced and distorted load currents. The series filter comprises two inverters, used to suppress voltage disturbances and handle source currents independently. This configuration is devised to reduce the overall cost of active compensators by using low-frequency high-current switches for the latter inverter. The filters are controlled separately using a novel control strategy. Since voltages at the point of common coupling contain interharmonics, conventional methods cannot be used for extracting voltage references. Therefore, voltage references are obtained from generated sinusoidal waveforms by a phase-locked loop. Current references are detected based on rotating frame vector mapping. Simulation results are presented to verify the system.

Real-Time Implementation of Shunt Active Filter P-Q Control Strategy for Mitigation of Harmonics with Different Fuzzy M.F.s

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.821-829
    • /
    • 2012
  • This research article presents a novel approach based on an instantaneous active and reactive power component (p-q) theory for generating reference currents for shunt active filter (SHAF). Three-phase reference current waveforms generated by proposed scheme are tracked by the three-phase voltage source converter in a hysteresis band control scheme. The performance of the SHAF using the p-q control strategy has been evaluated under various source conditions. The performance of the proposed control strategy has been evaluated in terms of harmonic mitigation and DC link voltage regulation. In order to maintain DC link voltage constant and to generate the compensating reference currents, we have developed Fuzzy logic controller with different (Trapezoidal, Triangular and Gaussian) fuzzy M.F.s. The proposed SHAF with different fuzzy M.F.s is able to eliminate the uncertainty in the system and SHAF gains outstanding compensation abilities. The detailed simulation results using MATLAB/SIMULINK software are presented to support the feasibility of proposed control strategy. To validate the proposed approach, the system is also implemented on a real time digital simulator and adequate results are reported for its verifications.

A Regeneration Inverter for Traction Applications with a Active Power Filter (능동전력필터를 가진 지하철 회생인버터 시스템)

  • Won, Chung-Yuen;Jang, Su-Jin;Kim, Yuen-Chung;Lee, Byoung-Kuk;Bae, Chang-Hwan;Kim, Yong-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.25-32
    • /
    • 2006
  • This paper proposes a regeneration inverter system, which can regenerate the excessive power form do bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are included to ac current source. The regeneration inverter is operated as two modes. In the regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and in the active power filter mode, it can compensate harmonic distortion produced by the rectifier substation. In this paper, the regeneration inverter uses PWM DC/AC inverter algorithm and the active power filter uses p-q theory. From the informative simulation and experimental results, which are performed wiith a prototype rated 3.7[kw], it can expected that the proposed system can be effectively applied in the real traction system rated 100[kw].