• Title/Summary/Keyword: active motion

Search Result 921, Processing Time 0.025 seconds

An Adaptive Motion Estimation Technique Using Temporal Continuity of Motion

  • Park, Jung-Hyun;Lee, Kyeong-Hwan;Kim, Duk-Gyoo
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.7-10
    • /
    • 2000
  • Fast block motion estimation technique is proposed to reduce the computational complexity in video coding. In the conventional methods the size of search region is fixed. For small motion regions like background the small size of sea of search region is enough to find a block motion. But for active motion regions the large size of search region is preferred to figure out the accurate motion vector. Therefore, it is reasonable that a block motion is estimated in the variable search region (both the size and the position of it). That is to say, the search region varies according to the predicted motion characteristics of a block. The block motion in video frames has temporal continuity and then the search region of a current block is predicted using the block motion of previous blocks. The computational complexity of the proposed technique is significantly reduced with a good picture quality compared to the conventional methods.

  • PDF

Comparison of Immediate Effects of Pain, Range of Motion and Treatment Satisfaction on Difference of Applying Joint Mobilization Levels in Patients With Acute Mechanical Neck Pain (급성 기계적 경부통 환자들의 관절가동술 적용 위치에 따른 통증과 가동범위와 치료 만족도의 즉각적인 효과 비교)

  • Lee, Nam-yong;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.50-60
    • /
    • 2015
  • The purpose of this study was to apply the joint mobilization technique to the level of segments with pain and to the level of segments with hypomobility respectively and compare the immediate effects of the joint mobilization technique on the pain, the active cervical range of motion (ROM), and treatment satisfaction of patients with acute mechanical neck pain. After the baseline assessment, forty-two patients were randomized into two groups: a painful group ($n_1=21$) that received joint mobilization at the most painful cervical spine level and a hypomobile group ($n_2=21$) that received joint mobilization at the most hypomobile cervical level. The patients received an intervention that applied unilateral posterior-anterior gliding for 5 minutes and two repetitions of 10 times of active extension motion with distraction. In the Wilcoxon signed-rank test, the painful group and the hypomobile group were improved significantly in all pain variables (p<.001), while the painful group was improved significantly in the active cervical flexion (p<.001), extension (p<.001), left side-bending (p<.01), right side-bending (p=.001), left rotation (p<.001), and right rotation (p<.001). The hypomobile group was significantly improved in active cervical flexion (p=.001), extension (p<.001), left side-bending (p<.05), right side-bending (p=.001), left rotation (p=.001), and right rotation (p<.01) after intervention. In the Mann-Whitney U test, there was no significant difference in any of the dependent variables after the intervention between the two groups, but the painful group was slightly superior to the hypomobile group in all variables except for the right lateral flexion ROM and treatment satisfaction. These outcomes suggest that the cervical joint mobilization may be applied to either the level of painful segments or the hypomobile segments for the treatment of patients with acute mechanical neck pain.

The Motion of Plasma in an Excited Quiescent Filament

  • Song, Dong-Uk;Chae, Jong-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.48.2-48.2
    • /
    • 2010
  • Quiescent filaments are bigger, more stable, and longer lived than active region filaments. So, the shape of a quiescent filament changes little during its lifetime and a fast motion of plasma rarely occurs. But when it is dynamically influenced by external phenomena, a rapid motion of plasma may temporarily occur. By analyzing the motion of plasma we can infer some of the magnetic structure permeating such an excited quiescent filament. We analyzed the H$\alpha$ images of a quiescent filament in the northern hemisphere that was observed at Big Bear Solar Observatory on 2004 August 2, and found that: 1) the filament was excited by a flare that occurred in a remote active region located in the southern hemisphere, 2) By this excitation, a part of the filament moved vertically upward and horizontally out of main body, and then it stayed there without much motion. Then after it moved vertically downward and horizontally to the main body, 3) the final position of plasma, however, was not the same as the initial position, being about 14Mm above it. We suggest that the filament was initially in a more or less static equilibrium. The excitation of the filament broke the initial equilibrium, and then brought about a new one that is different from the original one. Since the filament should have magnetic field, it is likely that both the equilibria may have been maintained by diplike magnetic structures. Furthermore, the transition from one equilibrium to another as we inferred should have accompanied a permanent change of magnetic configuration as well.

  • PDF

Low-computation Motion Tracker Unit Linkable to Video Codec for Object Tracking Camera (동영상 코덱과 연동이 가능한 객체 추적 카메라용 저연산량 움직임 추적기)

  • Yang, Hyeon-Cheol;Lee, Seong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.66-74
    • /
    • 2008
  • Surveillance system using active tracking camera has no distance limitation of surveillance range compared to supersonic or sound sensors. However, complex motion tracking algorithm requires huge amount of computation. Compared to conventional methods using DSPs or embedded processors, this paper proposes and implements a novel motion tracker unit that detects and extracts motion information of moving objects by using picture difference of consecutive frames. The proposed motion tracker unit was implemented in FPGA with about 13,000 gates. It processes NTSC format video and was verified by embedding it into the active surveillance camera system. We also propose and implements a motion estimator unit linkable to video codec by embedding the proposed motion tracker unit into ready-made motion estimator unit. The implemented motion estimator unit is about 17,000 gates in $0.35{\mu}m$ process.

Clinical and Electromyographic Study of the Effects of Muscle Relaxation Appliance of Craniomandibular Disorder Patients (근이완장치가 두개하악장애환자에 미치는 영향에 대한 임상 및 근전도학적 연구)

  • Bong-Jik Shu;Myung-Yun Ko
    • Journal of Oral Medicine and Pain
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 1991
  • The author studied the changes of subjective, objective symptoms and muscle activities with EM2 (myo-tronics Co., Seattle, USA) before and after MRA therapy. The 11 patients were treated with MRA and active range of motion, pain and mouth opening limitation were checked at each visit for 6-8 weeks. Electromyographic activities were measured in both anterior lobe of temporalis and middle fibers of masseter at the position in rest, clenching and mastication. The obtained results were as follows : 1. There were significant decrease in pain and mouth opening limitation and significant increase in active range of motion after MRA therapy. 2. The muscle activities tended to decrease in general, especially in the temporal and masseter muscles on clenching and in the masseter on mastication after MRA therapy. 3. There were no significant differences in muscle activities between affected and unaffected side, but there was significant differences in temporal muscle on clenching side after therapy. 4. There were no significant differences in active range of motion, pain and mouth opening limitation between acute and chronic groups. 5. There was more significant decrease in muscle activities of the affected side in acute group than those in chronic group.

  • PDF

Study on the Air Bearings with Actively Controllable Magnetic Preloads for an Ultra-precision Linear Stage (초정밀 직선 이송계용 능동 자기예압 공기베어링에 관한 연구)

  • Ro, Seung-Kook;Kim, Soo-Hyun;Kwak, Yoon-Keun;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.134-142
    • /
    • 2008
  • In this paper, we propose a precise linear motion stage supported by magnetically preloaded air bearings. The eight aerostatic bearings with rectangular carbon porous pads were located only one side of vertical direction under the platen where four bearings are in both sides of horizontal direction as wrap-around-design, and this gives simpler configuration than which constrained by air bearings for all direction. Each of the magnetic actuators has a permanent magnet generating static magnetic flux far required preload and a coil to perturb the magnetic farce resulting adjustment of air- bearing clearance. The characteristics of porous aerostatic bearing are analyzed by numerical analysis, and analytic magnetic circuit model is driven for magnetic actuator to calculate preload and variation of force due to current. A 1-axis linear stage motorized with a coreless linear motor and a linear encoder was designed and built to verify this design concept. The load capacity, stiffness and preload force were examined and compared with analysis. With the active magnetic preloading actuators controlled with DSP board and PWM power amplifiers, the active on-line adjusting tests about the vertical, pitching and rolling motion were performed. It was shown that motion control far three DOF motions were linear and independent after calibration of the control gains.

Development of Anthropomorphic Robotic Joint (인간형 로봇관절의 개발)

  • Ryu, Seong-Mu;Baek, Sang-Hun;Choe, Hyeok-Ryeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.89-97
    • /
    • 2001
  • In this paper, we present a new two-dof anthropomorphic joint mechanism that enables to mimic the humanlike motion. The proposed mechanism, called Double Active Universal Joint(DAUJ), generates a two-dof swivel motion without rolling by the coupled motion of two independent motor. In addition, we perform basic experiments to confirm the effectiveness of the proposed mechanism and the results are reported.

Development of a 3D Motion Capture System with Monocular PSD Camera and Two Active Markers (단안 PSD카메라와 두 능동마커를 이용한 3차원 모션인식 시스템 개발)

  • Seo, Pyeong-Won;Ryu, Young-Kee;O, Chun-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1026
    • /
    • 2008
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The micro-controller calculates the 3D position of the markers using only the measured intensity and the 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system has the advantages of the compact size, the low cost, the easy installation, and the high frame rates to be suitable for high speed motion tracking in games.

  • PDF

A Study on Proportional and Derivative Control of Fluid Film Journal Bearings (유체 윤활 베어링의 비례 및 미분 제어에 관한 연구)

  • 노병후;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.212-217
    • /
    • 2001
  • This paper presents the stability characteristics of a rotor-bearing system supported by actively controlled hydrodynamic journal bearing. The proportional and derivative controls including coupled motion are adopted for the control algorithm to control the hydrodynamic journal bearing with a circumferentially groove. Also, the cavitation algorithm implementing the Jakobsson-Floberg-Olsson boundary condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis which uses the Reynolds condition. The stability characteristics are investigated with the Routh-Hurwitz criteria using the linear dynamic coefficients which are obtained from the perturbation method. The stability characteristics of the rotor-bearing system supported by active controlled hydrodynamic journal bearing are investigated for various control gain. It is found that the speed at onset of instability is increased for both proportional and derivative control of the bearing, and the proportional and derivative control of coupled motion is more effective than proportional and derivative control of uncoupled motion.

  • PDF

Study on Advanced Knee Joint Linkage of Active Prosthesis Leg (진보된 능동 의족 무릎 관절 구조 연구)

  • Bak, J.H.;Lee, K.H.;Lee, C.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • In this study, an advanced knee joint for active prosthesis leg driven by a linear actuator is suggested. The structure of knee joints of existing active prosthesis legs consists of three links. This kind of linkage requires large torque to drive the active prosthesis legs. Thus a new linkage structure is suggested to solve such problem in this paper. Motion characteristics of the suggested linkage are examined in the simulation. The motion simulation results show that the proposed linkage is able to imitate human gait cycles with the half of linear actuator speed in existing linkages.

  • PDF