• 제목/요약/키워드: accuracy test

검색결과 4,873건 처리시간 0.033초

Check4Urine: Smartphone-based Portable Urine-analysis System (Check4Urine: 스마트폰 기반 휴대용 소변검사 시스템)

  • Cho, Jungjae;Yoo, Joonhyuk
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2015
  • Recently, a few image-processing based mobile urine testers have actively been studied since the urine-analysis result can be available to the user in real time immediately after the test is done. However, the accuracy of test result can be severely degraded due to variable illumination environments and a variety of manners to capture the image with a camera embedded in the smartphone according to different users. This paper proposes the Check4Urine system, a novel smartphone-based portable urine-analysis tester and provides three techniques to improve such a performance degradation problem robust to various test environments and disturbances, which are the compensation algorithm to correct the varying illumination effect, an urine strip detection algorithm robust to edge loss of the object image, and the color decision algorithm based on the pre-processed reference table. Experimental results show that the proposed Check4Urine system increases the accuracy of urine-analysis by 20-50% at various test conditions, compared with the existing image-processing based mobile urine tester.

A Prediction of Chip Quality using OPTICS (Ordering Points to Identify the Clustering Structure)-based Feature Extraction at the Cell Level (셀 레벨에서의 OPTICS 기반 특질 추출을 이용한 칩 품질 예측)

  • Kim, Ki Hyun;Baek, Jun Geol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • 제40권3호
    • /
    • pp.257-266
    • /
    • 2014
  • The semiconductor manufacturing industry is managed by a number of parameters from the FAB which is the initial step of production to package test which is the final step of production. Various methods for prediction for the quality and yield are required to reduce the production costs caused by a complicated manufacturing process. In order to increase the accuracy of quality prediction, we have to extract the significant features from the large amount of data. In this study, we propose the method for extracting feature from the cell level data of probe test process using OPTICS which is one of the density-based clustering to improve the prediction accuracy of the quality of the assembled chips that will be placed in a package test. Two features extracted by using OPTICS are used as input variables of quality prediction model because of having position information of the cell defect. The package test progress for chips classified to the correct quality grade by performing the improved prediction method is expected to bring the effect of reducing production costs.

Accuracy of Paper-pencil Test used in Investigation of Control-display Stereotype - Focused on Stereotype for Control-burner Relationship of Four-stove Range - (조종장치-표시장치 스테레오타이프 조사를 위한 설문조사법의 정확성 - 4구 가스렌지 조종장치-버너 연결에 대한 스테레오타이프를 중심으로 -)

  • Kee, Dohyung
    • Journal of the Korean Society of Safety
    • /
    • 제28권3호
    • /
    • pp.114-117
    • /
    • 2013
  • The purpose of this study is to empirically investigate accuracy of paper-pencil test used in surveying control-display stereotype. For doing this, three paper-pencil tests dealing with stereotype for control-burner relationship of four-stove gas range, in which three different gas range images were provided, were performed and the results were compared with those of existing studies. The result of the paper-pencil test using simple image composed of line and circle was different from that of the real model simulation, while the results of the other two tests and a previous study providing more realistic images were the same as that of the real model simulation. Furthermore, the proportion of responses coinciding with the real model simulation increased as images used became closer to real range. It is concluded that the paper-pencil tests well designed using realistic images may produce the same stereotype as the real model simulation.

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

The Effect of Test Variables on the Accuracy of Equo-Tip Hardness (Equo-Tip 경도값에 미치는 실험변수의 영향)

  • Nahm, S.H.;Jeon, S.B.;Kim, J.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제3권2호
    • /
    • pp.32-36
    • /
    • 1990
  • For the accurate measurements of hardness in a material, it is necessary to have a thorough understanding of the effects of test variables on the accuracy of hardness value. For the rebound hardness test, major test variables are the radius of hammer ball tip, type of backing materials, size and roughness of the specimen. In this study, effects of these variables on Equo-Tip hardness value were investigated. Hardness measurements were carried out using WC balls with various sizes of worn-ot zone. The sample materials chosen for the experiments were commercial standard hardness blocks and SM45C steel bars subjected to either normalization or quench and temper treatments. As backing materials, aluminum, steel and rubber plates were used in all the experiments. Experimental results show that for the accurate measurements of Equo-tip hardness, it is necessary to use the hammer ball with a worn-out zone parameter of less than 0.23, and the recommended minimum thickness and width of the specimen are 25mm and 70mm, respectively. Further for the surface preparation, the specimens need to be polished with an emery paper of No. 400 or finer, and for the backing matrials, it is recommended to use steels or rubbers.

  • PDF

Envisaging Macroeconomics Antecedent Effect on Stock Market Return in India

  • Sivarethinamohan, R;ASAAD, Zeravan Abdulmuhsen;MARANE, Bayar Mohamed Rasheed;Sujatha, S
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권8호
    • /
    • pp.311-324
    • /
    • 2021
  • Investors have increasingly become interested in macroeconomic antecedents in order to better understand the investment environment and estimate the scope of profitable investment in equity markets. This study endeavors to examine the interdependency between the macroeconomic antecedents (international oil price (COP), Domestic gold price (GP), Rupee-dollar exchange rates (ER), Real interest rates (RIR), consumer price indices (CPI)), and the BSE Sensex and Nifty 50 index return. The data is converted into a natural logarithm for keeping it normal as well as for reducing the problem of heteroscedasticity. Monthly time series data from January 1992 to July 2019 is extracted from the Reserve Bank of India database with the application of financial Econometrics. Breusch-Godfrey serial correlation LM test for removal of autocorrelation, Breusch-Pagan-Godfrey test for removal of heteroscedasticity, Cointegration test and VECM test for testing cointegration between macroeconomic factors and market returns,] are employed to fit regression model. The Indian market returns are stable and positive but show intense volatility. When the series is stationary after the first difference, heteroskedasticity and serial correlation are not present. Different forecast accuracy measures point out macroeconomics can forecast future market returns of the Indian stock market. The step-by-step econometric tests show the long-run affiliation among macroeconomic antecedents.

Identification of motion error sources in NC machine tools by a circular interpolation test (원호보간시험에 의한 수치제어 공작기계의 운동오차원인 진단에 관한 연구)

  • Hong, Seong-Wook;Shin, Young-Jae;Lee, Hu-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제10권2호
    • /
    • pp.126-137
    • /
    • 1993
  • This paper presents an efficient method for the identification of motion error sources in NC machine tools by making use of the circular interpolation test, which is often used in estimating the motion accuracy of NC machine tools. Mathematical formulae are described for motion errors due to various kinds of error sources. Two identification formulae are proposed: one is based on the frequency analysis and the other is formulated with the weithted residual method. Motion error signal is classified into two patterns, mean errors(mean of CW and CCW test signals from mean errors). The sources of the mean errors are identified by using the frequency analysis technique and the sources of the deviation errors by the weighted residual formulaltion. A menu driven, user oriented, computer program is written to realize the full steps of the proposed identificationprocedure. Then, the identification method is applied to two NC machine tools.

  • PDF

The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis (당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석)

  • Mo, Jin A;Jang, Sunyoung;Bang, Hee Young
    • Korean Journal of Health Education and Promotion
    • /
    • 제31권4호
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • 제18권6호
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

Association between the Computerized Neurocognitive Function Test, Computer Experience, and Satisfaction in the Elderly (노인의 전산화 신경인지 검사와 만족도, 컴퓨터 이용경험 사이의 연관성)

  • Moon, Jong-Hoon;Yang, Seung-Bum;Jeon, Min-Jae
    • The Journal of the Korea Contents Association
    • /
    • 제19권9호
    • /
    • pp.452-459
    • /
    • 2019
  • The purpose of this study was to examine the relationship between the neurocognitive function test (CN Test), computer experience, and satisfaction in the elderly. We recruited 52 healthy elderly persons (25 males and 27 females) for this study. The subjects did the CN Test (accuracy, response time) and evaluated their computer experience and satisfaction with the CN Test. We used the independent t test and Pearson correlations for statistical analysis. The elderly without computer experience were older than the elderly with computer experience (p < .05) and education level was lower (p < .05). The elderly with computer experience were higher the satisfaction than the elderly without computer experience, the CN Test was more accurate, and response time was faster (p < .05). In the correlation analysis, the higher the age and the lower the education level, the lower the accuracy of the CN Test and the faster the response time (p < .05). Satisfaction was negatively correlated with age, and was statistically correlated with education level (p < .05). The satisfaction level with the CN Test by the elderly has a moderate relationship with the level of education and computer experience.