• 제목/요약/키워드: accuracy test

검색결과 4,827건 처리시간 0.029초

비지도학습 데이터의 정확성 측정을 위한 클러스터별 분류 평가 예측 모델에 대한 연구 (A Study on Classification Evaluation Prediction Model by Cluster for Accuracy Measurement of Unsupervised Learning Data)

  • 정세훈;김종찬;김치용;유강수;심춘보
    • 한국멀티미디어학회논문지
    • /
    • 제21권7호
    • /
    • pp.779-786
    • /
    • 2018
  • In this paper, we are applied a nerve network to allow for the reflection of data learning methods in their overall forms by using cluster data rather than data learning by the stages and then selected a nerve network model and analyzed its variables through learning by the cluster. The CkLR algorithm was proposed to analyze the reaction variables of clustering outcomes through an approach to the initialization of K-means clustering and build a model to assess the prediction rate of clustering and the accuracy rate of prediction in case of new data inputs. The performance evaluation results show that the accuracy rate of test data by the class was over 92%, which was the mean accuracy rate of the entire test data, thus confirming the advantages of a specialized structure found in the proposed learning nerve network by the class.

Improving Urban Vegetation Classification by Including Height Information Derived from High-Spatial Resolution Stereo Imagery

  • Myeong, Soo-Jeong
    • 대한원격탐사학회지
    • /
    • 제21권5호
    • /
    • pp.383-392
    • /
    • 2005
  • Vegetation classes, especially grass and tree classes, are often confused in classification when conventional spectral pattern recognition techniques are used to classify urban areas. This paper reports on a study to improve the classification results by using an automated process of considering height information in separating urban vegetation classes, specifically tree and grass, using three-band, high-spatial resolution, digital aerial imagery. Height information was derived photogrammetrically from stereo pair imagery using cross correlation image matching to estimate differential parallax for vegetation pixels. A threshold value of differential parallax was used to assess whether the original class was correct. The average increase in overall accuracy for three test stereo pairs was $7.8\%$, and detailed examination showed that pixels reclassified as grass improved the overall accuracy more than pixels reclassified as tree. Visual examination and statistical accuracy assessment of four test areas showed improvement in vegetation classification with the increase in accuracy ranging from $3.7\%\;to\;18.1\%$. Vegetation classification can, in fact, be improved by adding height information to the classification procedure.

An improvement of Simplified Atmospheric Correction : MODIS Visible Channel

  • Lee, Chang-Suk;Han, Kyung-Soo
    • 대한원격탐사학회지
    • /
    • 제25권6호
    • /
    • pp.487-499
    • /
    • 2009
  • Atmospheric correction of satellite measurements is a major step to estimate accurate surface reflectance of solar spectrum channels. In this study, Simplified Method for the Atmospheric Correction (SMAC) radiative transfer model used to retrieve surface reflectance from MODIS (MODerate resolution Imaging Spectrometer) top of atmosphere (TOA) reflectance. It is fast and simple atmospheric correction method, so it uses for work site operation in various satellite. This study attempts a test of accuracy of SMAC through a sensitivity test to detected error sources and to improve accuracy of surface reflectance using SMAC. The results of SMAC as compared with MODIS surface reflectance (MOD09) was represented that low accuracy ($R^2\;=\;0.6196$, Root Means Square Error (RMSE) = 0.00031, bias = - 0.0859). Thus sensitivity analysis of input parameters and coefficients was conducted to searching error sources. Among the input parameters, Aerosol Optical Depth (AOD) is the most influence input parameter. In order to modify AOD term in SMAC code, Stepwise multiple regression was performed with testing and remove variable in three stages with independent variables of AOD at 550nm, solar zenith angle, viewing zenith angle. Surface reflectance estimation by using Newly proposed AOD term in the study showed that improve accuracy ($R^2\;=\;0.827$, RMSE = 0.00672, bias = - 0.000762).

Pest Control System using Deep Learning Image Classification Method

  • Moon, Backsan;Kim, Daewon
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권1호
    • /
    • pp.9-23
    • /
    • 2019
  • In this paper, we propose a layer structure of a pest image classifier model using CNN (Convolutional Neural Network) and background removal image processing algorithm for improving classification accuracy in order to build a smart monitoring system for pine wilt pest control. In this study, we have constructed and trained a CNN classifier model by collecting image data of pine wilt pest mediators, and experimented to verify the classification accuracy of the model and the effect of the proposed classification algorithm. Experimental results showed that the proposed method successfully detected and preprocessed the region of the object accurately for all the test images, resulting in showing classification accuracy of about 98.91%. This study shows that the layer structure of the proposed CNN classifier model classified the targeted pest image effectively in various environments. In the field test using the Smart Trap for capturing the pine wilt pest mediators, the proposed classification algorithm is effective in the real environment, showing a classification accuracy of 88.25%, which is improved by about 8.12% according to whether the image cropping preprocessing is performed. Ultimately, we will proceed with procedures to apply the techniques and verify the functionality to field tests on various sites.

전이학습 기반 사출 성형품 burr 이미지 검출 시스템 개발 (Development of a transfer learning based detection system for burr image of injection molded products)

  • 양동철;김종선
    • Design & Manufacturing
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2021
  • An artificial neural network model based on a deep learning algorithm is known to be more accurate than humans in image classification, but there is still a limit in the sense that there needs to be a lot of training data that can be called big data. Therefore, various techniques are being studied to build an artificial neural network model with high precision, even with small data. The transfer learning technique is assessed as an excellent alternative. As a result, the purpose of this study is to develop an artificial neural network system that can classify burr images of light guide plate products with 99% accuracy using transfer learning technique. Specifically, for the light guide plate product, 150 images of the normal product and the burr were taken at various angles, heights, positions, etc., respectively. Then, after the preprocessing of images such as thresholding and image augmentation, for a total of 3,300 images were generated. 2,970 images were separated for training, while the remaining 330 images were separated for model accuracy testing. For the transfer learning, a base model was developed using the NASNet-Large model that pre-trained 14 million ImageNet data. According to the final model accuracy test, the 99% accuracy in the image classification for training and test images was confirmed. Consequently, based on the results of this study, it is expected to help develop an integrated AI production management system by training not only the burr but also various defective images.

Comparison of accuracy of breeding value for cow from three methods in Hanwoo (Korean cattle) population

  • Hyo Sang Lee;Yeongkuk Kim;Doo Ho Lee;Dongwon Seo;Dong Jae Lee;Chang Hee Do;Phuong Thanh N. Dinh;Waruni Ekanayake;Kil Hwan Lee;Duhak Yoon;Seung Hwan Lee;Yang Mo Koo
    • Journal of Animal Science and Technology
    • /
    • 제65권4호
    • /
    • pp.720-734
    • /
    • 2023
  • In Korea, Korea Proven Bulls (KPN) program has been well-developed. Breeding and evaluation of cows are also an essential factor to increase earnings and genetic gain. This study aimed to evaluate the accuracy of cow breeding value by using three methods (pedigree index [PI], pedigree-based best linear unbiased prediction [PBLUP], and genomic-BLUP [GBLUP]). The reference population (n = 16,971) was used to estimate breeding values for 481 females as a test population. The accuracy of GBLUP was 0.63, 0.66, 0.62 and 0.63 for carcass weight (CWT), eye muscle area (EMA), back-fat thickness (BFT), and marbling score (MS), respectively. As for the PBLUP method, accuracy of prediction was 0.43 for CWT, 0.45 for EMA, 0.43 for MS, and 0.44 for BFT. Accuracy of PI method was the lowest (0.28 to 0.29 for carcass traits). The increase by approximate 20% in accuracy of GBLUP method than other methods could be because genomic information may explain Mendelian sampling error that pedigree information cannot detect. Bias can cause reducing accuracy of estimated breeding value (EBV) for selected animals. Regression coefficient between true breeding value (TBV) and GBLUP EBV, PBLUP EBV, and PI EBV were 0.78, 0.625, and 0.35, respectively for CWT. This showed that genomic EBV (GEBV) is less biased than PBLUP and PI EBV in this study. In addition, number of effective chromosome segments (Me) statistic that indicates the independent loci is one of the important factors affecting the accuracy of BLUP. The correlation between Me and the accuracy of GBLUP is related to the genetic relationship between reference and test population. The correlations between Me and accuracy were -0.74 in CWT, -0.75 in EMA, -0.73 in MS, and -0.75 in BF, which were strongly negative. These results proved that the estimation of genetic ability using genomic data is the most effective, and the smaller the Me, the higher the accuracy of EBV.

Comparisons of Accuracy of Knee Joint Motion During Closed verse Open Kinetic Chain Tasks in Subjects with Flexible Flatfeet

  • Kim, Ju Sang;Kwon, Younghyun;Lee, Mi Young
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.13-17
    • /
    • 2019
  • Purpose: This study examined the effects of flexible flatfeet on the accuracy of knee joint motions in closed and open kinetic chain tasks. Methods: Twenty-four healthy participants were recruited for this study. The subjects were divided into two groups using a navicular drop (ND) test: flexible flatfoot group (n=12, male: 6, aged $22.00{\pm}2.22years$) and age-matched control group (n=12, males: 6, aged $22.17{\pm}1.53years$). The accuracy of knee motion was measured quantitatively by tracing through the flexion and extension motion of the knee joints in the closed kinetic chain and the open kinetic chain. Results: There was a significant difference in the accuracy index between the groups in closed kinetic chain task, but there was no significant difference in the open kinetic chain task. In addition, there was a significant difference in the accuracy index between the closed kinetic chain and the open kinetic chain task in the flexible flatfoot group. In addition, a significant negative correlation was observed between the ND and accuracy index in the closed kinematic chain task, but there was no significant relationship between the ND and accuracy index in the open kinematic chain task. Conclusion: Flexible flatfeet can affect the accuracy of the adjacent joints, such as the knee joint in the closed kinematic chain.

진단검사의 특성 추정을 위한 표본크기 (Sample Size Requirements in Diagnostic Test Performance Studies)

  • 박선일;오태호
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.73-77
    • /
    • 2015
  • There has been increasing attention on sample size requirements in peer reviewed medical literatures. Accordingly, a statistically-valid sample size determination has been described for a variety of medical situations including diagnostic test accuracy studies. If the sample is too small, the estimate is too inaccurate to be useful. On the other hand, a very large sample size would yield the estimate with more accurate than required but may be costly and inefficient. Choosing the optimal sample size depends on statistical considerations, such as the desired precision, statistical power, confidence level and prevalence of disease, and non-statistical considerations, such as resources, cost and sample availability. In a previous paper (J Vet Clin 2012; 29: 68-77) we briefly described the statistical theory behind sample size calculations and provided practical methods of calculating sample size in different situations for different research purposes. This review describes how to calculate sample sizes when assessing diagnostic test performance such as sensitivity and specificity alone. Also included in this paper are tables and formulae to help researchers for designing diagnostic test studies and calculating sample size in studies evaluating test performance. For complex studies clinicians are encouraged to consult a statistician to help in the design and analysis for an accurate determination of the sample size.

영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발 (Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition)

  • 이지은;주윤하;이정찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가 (Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment)

  • 황준호;권성민;최성기;성미애;이규복
    • 한국표면공학회지
    • /
    • 제51권5호
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.