• Title/Summary/Keyword: acceleration transfer

Search Result 256, Processing Time 0.026 seconds

Measurement of Mechanical-acoustic Transfer Functions of Vehicles by Combination of Mechanical and Acoustic Excitations (구조가진과 음향 가진의 결합에 의한 차량의 구조-음향 전달 함수 측정)

  • 고강호;이장무
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.158-164
    • /
    • 1999
  • In this paper a simple measurement technique for mechanical-acoustic transfer functions is proposed . The mechanical-acoustic transfer functions, generally , are measured through mechanical excitations ; impact hammers or shakers. Recently , by virtue of vibro-acoustical reciprocity principle, they are measured through acoustic excitations : loudspeakers. This kind of test needs to measure the volume velocity , the radiation characteristics of a sound source. Because the volume velocity of the sound source is changed by driving signal , it is difficult to measure it. However , the new method in this paper needs not to measure the volume velocity of a sound source by combination of mechanical and acoustic excitations. Moreover, this method has the methodological advantages, such as usage of a general loudspeaker for the reciprocal excitation, no sptatial limitations for measurements of mechanical-acoustic transfer functions.

  • PDF

Study on the Design of Cam-type Transfer Unit (대형 캠 타입 이송장치의 설계에 관한 연구)

  • 이택민;이동윤;양민양
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • This paper presents design solutions for cam type transfer unit in which feeding, lifting, and clamping motions are generated by cams. In order to achieve faster transfer motion, each designed cam must satisfy the given specifications such as velocity, acceleration, jerk, pressure angle, cam thickness, and torque. To reduce absolute torque magnitude and torque variation, a conjugate cam and a torque reduction cam are used respectively. The conjugate cam eliminates the redundant pre-load by using complementary cam to avoid jumping between a cam and a follower. The torque reduction cam reduces the torque variation by applying opposite torque to a cam shaft. The experimental result shows the reductions of the absolute torque value and torque variation. The improvement of working speed and life span of cam type transfer unit can be expected.

Laminar Forced Convective Heat Transfer to Near-Critical Water in a Tube

  • Lee, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1756-1766
    • /
    • 2003
  • Numerical modeling is carried out to investigate forced convective heat transfer to near-critical water in developing laminar flow through a circular tube. Due to large variations of thermo-physical properties such as density, specific heat, viscosity, and thermal conductivity near thermodynamic critical point, heat transfer characteristics show quite different behavior compared with pure forced convection. With flow acceleration along the tube unusual behavior of heat transfer coefficient and friction factor occurs when the fluid enthalpy passes through pseudocritical point of pressure in the tube. There is also a transition behavior from liquid-like phase to gas-like phase in the developing region. Numerical results with constant heat flux boundary conditions are obtained for reduced pressures from 1.09 to 1.99. Graphical results for velocity, temperature, and heat transfer coefficient with Stanton number are presented and analyzed.

Study on the Design of Cam-type Transfer Unit using Conjugate Cam (복소캠을 이용한 캠 타입 이송장치의 설계)

  • 이택민;이동윤;양민양
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.844-847
    • /
    • 2003
  • This thesis suggests design considerations and solutions for cam type transfer unit in which feed, lift, and clamp motions are occurred by cams. For fast transferring and avoiding cam breakage, each designed cam must satisfy the given specifications such like velocity, acceleration, jerk, pressure angle, ram thickness, and torque. To reduce absolute torque magnitude, conjugate cam is suggested. Conjugate cam eliminates the redundant pre-load by using complementary cam and follower to avoid jumping between them. The result from the prototype shows the reductions of the absolute torque value, and it indicates that conjugate cam could enhance the working speed of cam type transfer unit and extend of the life span of cam type transfer unit.

  • PDF

COSMIC RAY ACCELERATION AT COSMOLOGICAL SHOCKS: NUMERICAL SIMULATIONS OF CR MODIFIED PLANE-PARALLEL SHOCKS

  • KANG HYESUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.111-121
    • /
    • 2003
  • In order to explore the cosmic ray acceleration at the cosmological shocks, we have performed numerical simulations of one-dimensional, plane-parallel, cosmic ray (CR) modified shocks with the newly developed CRASH (Cosmic Ray Amr SHock) numerical code. Based on the hypothesis that strong Alfven waves are self-generated by streaming CRs, the Bohm diffusion model for CRs is adopted. The code includes a plasma-physics-based 'injection' model that transfers a small proportion of the thermal proton flux through the shock into low energy CRs for acceleration there. We found that, for strong accretion shocks with Mach numbers greater than 10, CRs can absorb most of shock kinetic energy and the accretion shock speed is reduced up to $20\%$, compared to pure gas dynamic shocks. Although the amount of kinetic energy passed through accretion shocks is small, since they propagate into the low density intergalactic medium, they might possibly provide acceleration sites for ultra-high energy cosmic rays of $E\ll10^{18}eV$. For internal/merger shocks with Mach numbers less than 3, however, the energy transfer to CRs is only about $10-20\%$ and so nonlinear feedback due to the CR pressure is insignificant. Considering that intracluster medium (ICM) can be shocked repeatedly, however, the CRs generated by these weak shocks could be sufficient to explain the observed non-thermal signatures from clusters of galaxies.

Experimental Investigation of Heat Transfer During Vertical Upward Flow of Supercritical CO2 in Circular Tube (초임계 이산화탄소의 수직 상향 유동에서의 관내 열전달에 관한 실험적 연구)

  • Kim, Dong Eok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.607-618
    • /
    • 2014
  • An experimental investigation of turbulent heat transfer during the vertical upward flow of supercritical $CO_2$ was conducted in a circular tube with inner diameter of 4.5 mm. The experiments were conducted at bulk fluid temperatures ranging from 29 to $115^{\circ}C$, pressures from 74.6 to 102.6 bar, local wall heat fluxes from 38 to $234kW/m^2$, and mass fluxes from 208 to $874kg/m^2s$. At moderate wall heat and low mass fluxes, the wall temperature had a noticeable peak value. For observing the buoyancy and flow acceleration effects on heat transfer, the ratios of Nusselt numbers from the experimental data and a reference correlation were compared with the $Bo^*$ and $q^+$ distributions. The flow acceleration parameter $q^+$ appropriately represented the heat transfer phenomena in the experiments. A new heat transfer correlation for the vertical upward flow of the supercritical pressure fluid was developed, and was found to agree with the experimental data with an error margin of ${\pm}30%$.

A Study on the Mass Transfer from a Square Cylinder Using Naphthalene Sublimation Technique (나프탈렌승화법을 이용한 사각관 주위에서의 물질전달에 관한 연구)

  • 유성연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1300-1310
    • /
    • 1990
  • Naphthalene sublimation technique is employed to investigate the mass transfer processes from a square cylinder at various Reynolds numbers and various angles of attack. Distribution of the local mass transfer coefficients on each face of the cylinder changes dramatically with the angle of attack. Such variation of local mass transfer rates closely connected with the complex flow phenomena such as stagnation, acceleration, separation, reattachment and vortex shedding. The average Sherwood number has a minimum value at 12.deg.-13.deg., and a maximum value at a=20.deg.-25.deg. A comparison of present mass transfer measurement with other heat transfer measurements, using the heat/mass transfer analogy, shows good agreement in average transfer rates, same trend but notable differences in local values. Therefore, naphthalene sublimation technique can be adopted to explore heat transfer processes in the complex flow situations, which is considered to be hardly possible with the conventional heat transfer measurements.

Approximate Solution for Conjugate Heat Transfer of Laminar Film Condensation on a Flat Plate (평판의 층류 막응축에서 복합열전달에 대한 근사해)

  • Lee Euk-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.509-518
    • /
    • 2005
  • Liquid film thickness in laminar film condensation for flow over a flat plate generally is so thin that both fluid acceleration and thermal convection within the liquid film can be neglected. An integral solution method is proposed to solve the conjugate problems of laminar film condensation and heat conduction in a solid wall. It is found that approximate solutions of the governing equations involve four physical parameters to describe the conjugate heat transfer problem for laminar film condensation. It is shown that the effects of interfacial shear. mass transfer and local heat transfer are strongly dependent on the thermo-physical properties of the working fluids and the Jacob number.

Study of variables influencing on the metal transfer in GMAW (GMAW의 금속이행에 영향을 주는 변수연구를 위한 계측 시스템과 조건해석)

  • 이세헌
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.73-79
    • /
    • 1993
  • The phenomenon of metal transfer has been investigated for different transfer modes using a digital high speed motion analyzer and an arc shadow-graphing system based on a laser source and related optical system. It was observed that the pinch instability phenomenon did not occur for the globular transfer mode, since the liquid globule was then spherical rateher than a cylindrical liquid bar. On increasing the ratio of carbon dioxide to argon, the transition current from globular to spray transfer generally increased, but it is interesting that the transition was observed to occur at the lowest current in a 5% CO$_{2}$-95% argon gas mixture. For pure carbon dioxide and helium shielding gases, the drop frequency increased slowly with increasing current. At high currents or an argon based shielding gas, the length of liquid bar decreased as the carbon dioxide content increased. The acceleration of a droplet within the arc was determined using the gas drag force theory and was found to be greater than the experimental results.

  • PDF

Transfer Path Analysis of vibration and noise for medical air compressor using PAK system (PAK system 을 이용한 의료용 컴프레서의 진동.소음 전달경로 해석)

  • Kang, Kwi-Hyun;Kang, Jin-Chul;Park, Chun-Kwon;Lee, Jeong-Hwan;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1000-1004
    • /
    • 2008
  • As performance of medical air compressor improve, the problem of noise increased. Noise is very important to medical air compressor because most of this installed inside of building. The main goal of this paper is show TPA (Transfer Path Analysis) result for contribution analysis using PAK system. Generally, the conventional TPA method consists of two steps. First, transfer functions between output sound and sources are measured by excitation experiment. Second, transferred sound in each transfer path is generated by multiplying the transfer function and the sound source signal. Then, if the output sound synthesized from all transferred sounds doesn't give good agreement with the measured output sound (i.e., the accuracies of the transfer functions are low), setting a suitable countermeasure guideline becomes difficult. For obtaining highly accurate transfer functions, eliminating correlations among transfer functions and noise included in the measured data are necessary. In the new method with PAK system, the vibration acceleration and sound signals around the sound sources and the output sound were measured simultaneously to obtain the transfer functions when compressor was operating. By applying PAK system, a highly accurate and efficient transfer path analysis method was developed that does not require an excitation experiment.

  • PDF