• Title/Summary/Keyword: absorbed dose

Search Result 572, Processing Time 0.024 seconds

Experimental Studies on Lead Toxicity in Domestic II. Histopathology (고양이의 납중독에 관한 실험적 연구 2. 조직병리학적 소견)

  • Hong Soon-Ho;Han Hong Ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.1
    • /
    • pp.485-505
    • /
    • 1994
  • Lead toxicity was evaluated in forty-five cats on a balanced diet, treated with 0(control), 10, 100(low), 1, 000, 2, 000 and 4, 000(high)ppm of lead acetate orally on a body weight basis. The objectives were to describe the gross and histopathologic changes and to demonstrate what tissue lead concentrations correlate with the known dosages of lead. In subclinical lead toxicity, greater than 80% of the absorbed lead was deposited in the bone, whereas in more acute lead toxicity, 42% of absorbed lead was deposited in the bone and 36% and 20% of absorbed lead was deposited in the kidneys and in the liver, respectively. No gross lesions were found in the nervous system. Yellow-brown colored livers appear to be associated with lead toxicity. Neuronal necrosis in the cerebrum was the most predominant histopathologic finding. Astrocytic proliferation in the cerebral gray matter was observed in 1 high dose cat. Gliosis was noted in the cerebral cortex of 6 high dose cats. Two high dose cats had demyelination in the deepest layer of the cortical gray matter of the cerebrum. Extravasation of red cells and cavitation around the vessels were found in the cerebrum of 1 high dose cat. Six high dose cats had degeneration of Purkinje cells in the cerebellum. The microscopic findings in the peripheral nerves were ambiguous. In more acute toxicity, the cats had lead inclusions in the epithelial cells of proximal tubules of the kidneys of 7 cats and hepatocytes of the liver of S cats. These inclusions could be seen wlth H&E, but were more prominent with orcein staining. Two high dose cats had granulomas and connective tissue hyperplasia between tubules of the kidneys. Periportal hepatocyte vacuolization was observed in the liver of 22 cats. Vacuolization of seminiferous tubules and a reduced number of spermatogonia(indicative of reduced spermatogenesis) were found in the testis of 5 treated cats. Cystic ovaries were observed in 3 high dose cats and poor development of oogonia was found in 2 cats. The diagnosis of lead toxicity in cats can be suspected on the basis of the histopathologic lesions described, and can be of value in contributing to a diagnosis. A reliable diagnosis of lead poisoning can be helped utilizing tissue lead analysis(post molten)

  • PDF

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

Dose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons

  • Yeom, Yeon Soo;Choi, Chansoo;Han, Haegin;Lee, Hanjin;Shin, Bangho;Nguyen, Thang Tat;Han, Min Cheol;Lee, Choonsik;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.843-852
    • /
    • 2019
  • In the present study, we established a comprehensive dataset of dose coefficients (DCs) of the new meshtype ICRP reference computational phantoms (MRCPs) for idealized external exposures of photons and electrons with the Geant4 code. Subsequently, the DCs for the nine organs/tissues, calculated for their thin radiosensitive target regions, were compared with the values calculated by averaging the absorbed doses over the entire organ/tissue regions to observe the influence of the thin sensitive regions on dose calculations. The result showed that the influences for both photons and electrons were generally insignificant for the majority of organs/tissues, but very large for the skin and eye lens, especially for electrons. Furthermore, the large influence for the skin eventually affected the effective dose calculations for electrons. The DCs of the MRCPs also were compared with the current ICRP-116 values produced with the current ICRP-110 reference phantoms. The result showed that the DCs for the majority of organs/ tissues and effective dose were generally similar to the ICRP-116 values for photons, except for very low energies; however, for electrons, significant differences from the ICRP-116 values were found in the DCs, particularly for superficial organs/tissues and skeletal tissues, and also for effective dose.

Initial Results of Low Earth Orbit Space Radiation Dosimeter on Board the Next Generation Small Satellite-2

  • Uk-Won Nam;Won-Kee Park;Sukwon Youn;Jaeyoung Kwak;Jongdae Sohn;Bongkon Moon;Jaejin Lee;Young-Jun Choi;Jungho Kim;Sunghwan Kim;Hongjoo Kim;Hwanbae Park;Sung-Joon Ye;Hongyoung Park;Taeseong Jang
    • Journal of Astronomy and Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.195-208
    • /
    • 2024
  • As human exploration goals shift from missions in low Earth orbit (LEO) to long-duration interplanetary missions, radiation protection remains one of the key technological issues that must be resolved. The low Earth orbit space radiation dosimeter (LEO-DOS) instrument to measure radiation levels and create a global dose map in the LEO on board the the next generation small satellite-2 (NEXTSat-2) was launched successfully on May 25, 2023 using the Nuri KSLV-III in Korea. The NEXTSat-2 orbits the Earth every 100 minutes, in an orbit with an inclination of 97.8° and an altitude of about 550 km above sea level. The LEO-DOS is equipped with a particle dosimeter (PD) and a neutron spectrometer (NS), which enable the measurement of dosimetric quantities such as absorbed dose (D), dose equivalent (H) for charged particles and neutrons. To verify the observations of LEO-DOS, we conducted a radiation dose estimation study based on the initial results of LEO-DOS, measured from June 2023 to September 2023. The study considered four source categories: (i) galactic cosmic ray particles; (ii) the South Atlantic Anomaly region of the inner radiation belt (IRB); (iii) relativistic electrons and/or bremsstrahlung in the outer radiation belt (ORB); and (iv) solar energetic particle (SEP) events.

Total Body Irradiation Technique : Basic Data Measurements and In Vivo Dosimetry (방사선 전신 조사 : 기본 자료 측정 및 생체내에서 선량 측정)

  • Choi Dong-Rak;Choi Ihl Bohng;Kang Ki Mun;Shinn Kyung Sub;Kim Choon Choo
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.219-223
    • /
    • 1994
  • This paper describes the basic data measurements for total body irradiation with 6 Mv photon beam including compensators design. The technique uses bilateral opposing fields with tissue compensators for the head, neck, lungs, and legs from the hip to toes. In vivo dosimetry was carried out for determining absorbed dose at various regions in 7 patients using diode detectors(MULTIDOSE,k Model 9310, MULTIDATA Co., USA). As a results, the dose uniformity of${\pm}3.5{\%}$(generally, within${\pm}10{\%}$can be achieved with out total body irradiation technique.

  • PDF

ESR Signal in Different Cuts of Irradiated Chicken, Pork and Beef

  • Nam, Hye-Seon;Yang, Jae-Seung;Ly, Sun-Yung
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to detect irradiated meat containing bones (chicken, pork and beef), to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals under 9 weeks of storage. Chicken, pork and beef were irradiated with doses 0, 1, 3, 5 and 7 kGy at room temperature using a Co-60 irradiator. Bones were pieced and dried, which were placed in a quartz tube within an Electron paramagnetic resonance (EPR) spectrometer resonator cavity. The irradiated bone presented an asymmetric absorption in shape, different from that of a non-irradiated one. The signal intensity of smaller animals are lower than larger species. Variation was observed between samples of the same species depending on the calcification status of the bone. Moreover different irradiation doses produced different signal areas that make possible to estimate the absorbed dose of treated meat. The ESR signal stability after irradiation was stable in even after a 9 week storage at room temperature.

  • PDF

Review on the Pre-treatment Quality Assurance for Intensity Modulated Radiation Therapy (세기변조 방사선치료의 환자 치료 전 선량보증에 대한 고찰)

  • Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.213-219
    • /
    • 2013
  • This review paper deals with the current statues of pre-treatment quality assurance conducted for Intensity modulated radiation therapy. Focusing on the issues relevant to two-dimensional verification of absorbed dose distribution, review was made for the papers published during the last 3~4 years. Lastly, the future development direction was projected.

Pharmacokinetic Study of Epigallocatechin Gallate in Rats (녹차의 주성분인 에피갈로카테킨 갈레이트의 흰쥐에서의 약물속도론적 연구)

  • Kim, Dong-Chool;Lim, Jae-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.3
    • /
    • pp.179-184
    • /
    • 1999
  • Phannacokinetics of epigallocatechin gallate(EGCG) was studied following i.v. bolus and oral administration in rats. The values of systemic clearance(CL) were $67.9{\pm}5.2$ and $26.5{\pm}1.4\;ml/min/kg$ following i.v. bolus administration of 1 mg and 5 mg EGCG, respectively. The values of volume of distribution at steady state (Vss) were $380{\pm}56$ and $835{\pm}84\;ml/kg$ after i.v. bolus administration of 1 mg and 5 mg EGCG, respectively. The decrease in the value of CL and the increase in the value of $V_{ss}$ as a function of EGCG dose (1 mg to 5 mg) suggest saturable mechanism(s) responsible for the distribution and elimination of EGCG. The fraction absorbed of EGCG after oral and intraduodenal administration of GTC were 13% and 22% of the dose, respectively. This result suggests a considerable degradation or elimination of EGCG in the gastrointestinal absorption after oral administration in rats.

  • PDF

Optimal Gamma Irradiation Using Monte Carlo Simulations on Wooden Cultural Properties, Gimjeotgae (목재 유물 김젖개의 몬테카를로 방법을 이용한 감마선 조사)

  • Yoon, Minchul;Choi, Jong-il;Lee, Yun Jong;Lim, Kil-Sung;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.95-100
    • /
    • 2012
  • In this study, there has been investigated the simulation of irradiation dose using Monte Carlo methodology for the biological control of wooden cultural property. In the evaluation of fungal contamination on wooden cultural properties, Cladosporium tenuissimum, Aspergillus versicolor, Penicillium sp. were mainly identified from the Gimjeotgae. But these microorganisms were completely inactivated by 20 kGy gamma-rays. For dosimetry simulation of wooden cultural properties, Monte Carlo methodology with MCNP was used. The radiation absorbed dose distribution was predicted at 8.2~18.9 kGy. These results show that irradiation is effective for biologic control of wooden cultural properties and Monte Carlo methodology is useful for non-destructive conservation and preservation of wooden cultural properties.