• 제목/요약/키워드: a single cycle

검색결과 963건 처리시간 0.029초

Feasibility of combinational burnable poison pins for 24-month cycle PWR reload core

  • Dandi, Aiman;Lee, MinJae;Kim, Myung Hyun
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.238-247
    • /
    • 2020
  • The Burnable Poison (BP) is very important for all Light Water Reactors in order to hold-down the initial excess reactivity and to control power peaking. The use of BP is even more essential as the excess reactivity increases significantly with a longer operation cycle. In this paper a feasibility study was conducted in order to investigate the benefits of a new combinational BP concept designed for 24-month cycle PWR core. The reference designs in this study are based on the two Korean fuel assemblies; 17 × 17 Westinghouse (WH) design and 16 × 16 Combustion Engineering (CE) design. A modification was done on these two designs to extend their cycle length from 18 months into 24 months. DeCART2D-MASTER code system was used to perform assembly and core calculations for both designs. A preliminary test was conducted in order to choose the best BP suitable for 24-month as a representative for single BP concept. The comparison between the results of two concepts (combinational BP concept and single BP concept) showed that the combinational BP concept can replace the single BP concept with better performance on holding down the initial excess reactivity without violating the design limitations.

액화석유가스 저장탱크로부터 발생하는 증발가스 재액화 공정의 최적화에 대한 연구 (An Optimization Study on the Reliquefaction of Boil-Off Gas from Liquefied Petroleum Gas Storage Tank)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.395-400
    • /
    • 2019
  • Comparative studies between single- and two-stage refrigeration cycle using propane as a refrigerant have been performed for a vapor recompression refrigeration cycle. PRO/II with PROVISION release 10.2 from AVEVA company was used, and the Soave-Redlich-Kwong equation of state model with Twu's alpha function was selected for the modeling and optimization of the refrigeration cycle for the reliquefaction of BOG coming out from the LPG storage tank. In two-stage refrigeraton cycle, 24.8% of compressor power was reduced compared to that of single-stage refrigeration cycle through the optimization works.

단기통 2사이클 압축점화기관의 시뮬레이션 (Simulation of the single-cylinder 2-stroke cycle compression ignition engine)

  • 유병철;김정순
    • 오토저널
    • /
    • 제8권1호
    • /
    • pp.62-74
    • /
    • 1986
  • The simulation of power cycle and unsteady gas exchange processes in the inlet and exhaust systems of the single-cylinder 2-stroke cycle compression ignition engine was studied in this paper. In power cycle process, the single-zone model proposed by Whitehouse and Way was used, and the convective and radiative heat transfer from cylinder contents to surroundings was considered. To solve the equations for gas exchange process, the generalized method of characteristics including area change, friction, heat transfer and entropy gradients was used. Also with the path line calculation, the entropy change along the path line and the variation of specific heat due to the change of temperature and the composition of cylinder gas were considered. As a result of the simulation, the change of pressure and temperature in the cylinder against the crank angle, the rate of net heat release, and the change of properties at each point in the inlet and exhaust pipe against the crank angle were obtained. The engine performances under various operating conditions were also calculated.

  • PDF

1인가구의 특성에 따른 생애주기별 건강성 결정요인 (Factors of Healthy Lifestyle by Life Cycle According to the Characteristics of Single-Person Households)

  • 서지원;송혜림;김정은;박정윤
    • 가족자원경영과 정책
    • /
    • 제28권1호
    • /
    • pp.13-25
    • /
    • 2024
  • 1인가구 증가는 전 세계적 현상으로 한국 또한 1인가구 비중의 증가가 급속히 진행 중이다. 1인가구는 그 형성 계기, 성별, 생애주기 등에 따라 매우 다양한 스펙트럼을 갖고 있으며, 각각의 특성을 반영한 지원이 가능하도록 1인가구 집단을 세분화하여 연구할 필요가 있다. 이 연구는 생애주기에 따라 청년기, 중장년기, 노년기 1인가구 등 세 개의 집단으로 분류하고, 1인가구 건강성 수준에 있어 집단 간 유의한 차이가 있는지, 나아가 건강성에 영향을 미치는 인구사회학적 특성 및 1인가구 삶의 특성에는 어떠한 것들이 있는지 살펴보았다. 분석을 위해 2022년도 김포시 거주 1인가구 237명을 대상으로 설문조사를 통해 수집된 자료를 이용하였고, 기술통계, 평균차이 검증(t-test, ANOVA), 중다회귀분석 등을 실시하였다. 1인가구의 전반적 건강성 수준을 살펴보면 생애주기별로 차이가 있었는데, 청년기 1인가구가 노년기 1인가구에 비해 건강성 수준이 유의하게 높았다. 중다회귀분석 결과, 1인가구 건강성에는 성별, 교육수준, 자발성, 차별경험 여부가 유의한 영향을 미치는 것으로 나타났으며, 건강성을 구성하는 하위영역별로 영향을 미치는 변수에는 차이가 있었다. 생애주기에 따른 1인가구의 건강성 수준에 대한 결과를 토대로 하여 1인가구 정책의 방향성을 논의하고 실천적 함의를 제공하였다.

ON A T-FUNCTION f(x)=x+h(x) WITH A SINGLE CYCLE ON ℤ2n

  • Rhee, Min Surp
    • 충청수학회지
    • /
    • 제24권4호
    • /
    • pp.927-934
    • /
    • 2011
  • Invertible transformations over n-bit words are essential ingredients in many cryptographic constructions. When n is large (e.g., n = 64) such invertible transformations are usually represented as a composition of simpler operations such as linear functions, S-P networks, Feistel structures and T-functions. Among them we study T-functions which are probably invertible and are very useful in stream ciphers. In this paper we study some conditions on a T-function h(x) such that f(x) = x + h(x) has a single cycle on ${\mathbb{Z}}_{2^n}$.

S-box 형태의 다 수열 발생기에 관한 연구 (On a Multiple-cycle Binary Sequence Genrator Based on S-box)

  • 이훈재
    • 한국정보처리학회논문지
    • /
    • 제7권5호
    • /
    • pp.1474-1481
    • /
    • 2000
  • The number of keystream cycle sequences has been proposed as a characteristic of binary sequence generator for cryptographic application, but in general the most of binary sequence generators have a single cycle. On the other hand, S-box has been used to block cipher for a highly nonlinear element and then we apply it to the stream cipher with a high crypto-degree. In this paper, we propose a multiple-cycle binary sequence generator based on S-box which has a high nonlinearity containing SAC property and analyze its period, linear complexity, randomness and the number of keystream cycle sequences.

  • PDF

외경홈을 지닌 C형 시험편의 저주기 피로수명평가 (Low Cycle Fatigue Life Evaluation of External Grooved C-shaped Specimen)

  • 이송인
    • 대한기계학회논문집A
    • /
    • 제21권2호
    • /
    • pp.199-208
    • /
    • 1997
  • A local strain approach was applied to an external single and double grooved C-shaped specimen in order to evaluate and predict the fatigue crack initiation life by using low cycle fatigue properties. The low cycle fatigue properties were determined from the strain-controlled fatigue tests using smooth cylindrical axial specimens. Fatigue crack initiation life was evaluated by a life prediction software, FALIPS, based on the local strain approach. The fatigue life was significantly influenced by the mean stress, and SWT parameter represented the fatigue life effectively. The predicted fatigue crack initiation life was then compared to the experimental fatigue life evaluated from the C-shaped fatigue test specimens. A good correlation was found between the experimental and predicted fatigue lives within factors of 2 and 4 for the single and double grooved C-shaped specimens respectively. Also, experimental fatigue life of the double grooved specimen was 10-12 times longer than that of the single grooved specimen.

세라믹/금속접합재의 강도에 미치는 열사이클 영향 (Effect of Thermal Cycle on Strength of Ceramic and Metal Joint)

  • 박영철;오세욱;김광영
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1664-1673
    • /
    • 1994
  • As a fundamental study on effects of thermal-cycles on residual stress of ceramics/metal joints, residual stresses in $Si_3N_4$/SUS304 joint specimens were measured before and single thermal-cycle by X-ray diffraction method and finite element method(FEM). The residual stress was found to increase after single thermal-cycle, which was agreeable with the results of residual stress measurement by X-ray diffraction method and residual stress analysis by finite element method. After the residual stress measurement, 4-point bending tests were performed. The relationship between the bending strength, the thermal-cycle temperature and hold time was examined. The bending strength was found to decrease with the increase of residual stress in linear relation.

에너지 절약용 냉방사이클 (Cooling Cycle for Energy Saving)

  • 이흥주;김용구
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

앳킨슨사이클 실현을 위한 단기통 저속 디젤기관의 구성과 기초 실험 (A Composition and Basis Experiment of Single Cylinder Low Speed Diesel Engine for Atkinson Cycle Materialization)

  • 장태익
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.461-466
    • /
    • 2013
  • In this research, the diesel cycle was thermodynamically interpreted to evaluate the possibility of high efficiency by converting diesel engine to the atkinson cycle, and general cycle features were analyzed after comparing these two cycles. That an experimental single cylinder and a long stroke diesel-atkinson engine, of which S/B ratio was more than 3, were manufactured. After evaluating the engine through basic experiments, a diesel engine was converted into the atkinson cycle by constituent VCR (variable compression ratio) device and VVT (variable valve timing) system. The experimental method was to observe compression work reduction effects due to low compression effects from delayed intake valve closing of the early stage atkinson engine. The result, the possibility of increasing compression ratio about each engine load was confirmation by constructing compensate expansion-compression ratio in accordance with the delayed intake valve close.