• Title/Summary/Keyword: a optic fiber

Search Result 888, Processing Time 0.029 seconds

Measurement of Spatial Resolution in Fiber-optic Image Guides

  • Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.33-36
    • /
    • 2001
  • Common methods of determining the spatial resolution of fiber-optic image guides are by measuring the diameter of individual microfibers or by the use of a resolution test target. However these methods cannot provide enough information of spatial resolution in ultrathin fiber-optic image guides. In this study, a simple method to measure the modulation transfer function (MTF) of an mage guide was developed. The MTFs of ultrathin image guides with 3 and 4${\mu}{\textrm}{m}$ Um diameter were measured by examining transmitted sharp edge image. This method should be especially useful for measuring spatial resolution of ultrahigh resolution image guides with less than 5 ${\mu}{\textrm}{m}$ diameter microfibers because their spatial resolution cannot be determined by individual microfiber diameter due to crosstalk and leaky ray phenomena.

Performance monitoring of offshore PHC pipe pile using BOFDA-based distributed fiber optic sensing system

  • Zheng, Xing;Shi, Bin;Zhu, Hong-Hu;Zhang, Cheng-Cheng;Wang, Xing;Sun, Meng-Ya
    • Geomechanics and Engineering
    • /
    • v.24 no.4
    • /
    • pp.337-348
    • /
    • 2021
  • Brillouin Optical Frequency Domain Analysis (BOFDA) is a distributed fiber optic sensing (DFOS) technique that has unique advantages for performance monitoring of piles. However, the complicated production process and harsh operating environment of offshore PHC pipe piles make it difficult to apply this method to pile load testing. In this study, sensing cables were successfully pre-installed into an offshore PHC pipe pile directly for the first time and the BOFDA technique was used for in-situ monitoring of the pile under axial load. High-resolution strain and internal force distributions along the pile were obtained by the BOFDA sensing system. A finite element analysis incorporating the Degradation and Hardening Hyperbolic Model (DHHM) was carried out to evaluate and predict the performance of the pile, which provides an improved insight into the offshore pile-soil interaction mechanism.

Performance Comparison between Optical Fiber Type ESPI and Bulk Type ESPI for the Internal Defect in Pressure Vessel (광섬유형과 벌크형 ESPI를 이용한 압력용기 내부 결함 측정에 관한 비교 연구)

  • Kim, Seong-Jong;Kang, Young-June;Hong, Kyung-Min;Lee, Jae-Hoon;Choi, Nak-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.177-184
    • /
    • 2012
  • An optical defect detection method using ESPI(electronic speckle pattern interferometry) is proposed. ESPI is widely used as a non-contact measurement system which show deformation and phase map in real time. ESPI can be divided as the in-plane, out-of-plane and shearography by operation principle and target object and also divided with bulk type and optic fiber type by the optic configurations. This paper is focused on optic fiber type out-of-plane ESPI, which has the following advantages: (1) low cost; (2) reduction of the unreliable factors generated by separated optic components; (3) simplification of the optic configuration; (4) great reduction of volume; (5) flexibility, to be easily designed into different structures to adapt to inaccessible environments such as pipeline cavity and so on.

Measurements and characterizations of cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam (고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Jeong, Sun-Cheol;Jun, Jae-Hun;Lee, Bong-Soo;Kim, Sin;Cho, Hyo-Sung;Park, Sung-Yong;Shin, Dong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.186-191
    • /
    • 2006
  • In general, Cerenkov light is produced by a charged particle that passes through a medium with a velocity greater than that of visible light. Although the wavelength of Cerenkov light is very broad, the peak is in the almost visible range from 400 to 480 nm. Therefore, it always causes a problem to detect a real light signal that is generated in the scintillator on the fiber-optic sensor tip for dose measurements of high-energy electron beam. The objectives of this study are to measure, characterize and remove Cerenkov light generated in a fiber-optic radiation sensor tip to detect a real light signal from the scintillator. In this study, the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam from a LINAC, and as a function of the energy of electron beam. As a measuring device, a photodiode-amplifier system is used, and a subtraction method using a background optical fiber is investigated to remove Cerenkov light.

Feasibility study on the development of respiration sensor using a chalcogenide optical fiber (Chalcogenide 광섬유를 이용한 호흡측정 센서 개발을 위한 기초 연구)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Oh, Jeong-Eun;Lee, Bong-Soo;Tack, Gye-Rae
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.331-336
    • /
    • 2007
  • In this study, we have fabricated an infrared optical fiber based sensor which can monitor the respiration of a patient. The design of a chalcogenide optical fiber based sensor is suitable for insertion into a high electro-magnetic field environment because the sensor consists of low cost and compact mid-infrared components such as an infrared light source, a chalcogenide optical fiber and a thermopile sensor. A fiber-optic respiration sensor is capable of detecting carbon dioxide ($CO_{2}$) in exhalation of a patient using the infrared absorption characteristics of carbon gases. The modulated infrared radiation due to the presence of carbon dioxide is guided to the thermopile sensor via a chalcogenide receiving fiber. It is expected that a mid-infrared fiber-optic respiration sensor which can be developed based on the results of this study would be highly suitable for respiration measurements of a patient during the procedure of an MRI.

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

Fiber-Optic Sensor Simultaneously Detecting Localized Surface Plasmon Resonance and Surface-Enhanced Raman Scattering

  • Norov, Erdene;Jeong, Hyeon-Ho;Park, Jae-Hyoung;Lee, Seung-Ki;Jeong, Dae Hong
    • Rapid Communication in Photoscience
    • /
    • v.2 no.2
    • /
    • pp.46-51
    • /
    • 2013
  • This study reports a fiber-optic sensor detecting biomolecule by simultaneously monitoring localized surface plasmon resonance (LSPR) from gold nanoparticles (Au NPs) of ca. $50{\pm}5$ nm attached on one end of optical fiber and surface enhanced Raman scattering (SERS) of the reporter molecules adsorbed on the gold surfaces as an additional sensing tool. The sensor was fabricated by immobilizing Au NPs on one end of an optical fiber by chemical reaction. LSPR and SERS signals of the sensor were measured using various refractive indices solutions. Finally, the sensor was applied to observe real-time LSPR sensor-gram and SERS spectra of the reporter molecule of 4-aminothiphenol during the antibody-antigen reaction of interferon-gamma (IFN-${\gamma}$) as a proof-concept experiment of biological applications.

Removal of Cerenkov Light in Fiber-optic Radiation Sensor Using Optical Filters (광학 필터를 이용한 광섬유 방사선 센서의 체렌코프 빛 제거)

  • Jang, Kyoung-Won;Lee, Bong-Soo;Cho, Dong-Hyun;Kim, Hyung-Shik;Yi, Jeong-Han;Lee, Jeong-Whan;Kim, Sin;Cho, Hyo-Sung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.312-316
    • /
    • 2006
  • In this study, a miniature fiber-optic radiation sensor has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. The intensity of Cerenkov light is measured and characterized as a function of the incident angle of the electron beam from a LINAC. Also, a subtraction method using a background optical fiber without a scintillator and an optical discrimination method using optical filters are investigated to remove Cerenkov light, which could cause problems or limit the accuracy for detecting a fluorescent light signal in a fiber-optic radiation sensor.

Development of Fiber Optic Accelerometer for Third-Party Damage Detection (타공사 감시를 위한 광섬유 가속도계의 개발)

  • Park, Ho-Rim;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1551-1558
    • /
    • 2001
  • Recently, a number of underground pipelines have been drastically increased. The integrity of these buried pipelines, especially gas transmitting pipelines, is of importance due to an explosive characteristic of natural gas. The third party damage is known as one of the most critical factor which causes fatal accidents. For this reason, a number of systems detecting third party damage are under development. The major concern in the development of third party damage detection system is to transmit vibration signals out of accelerometer to signal conditioner and data acquisition system without any interference caused by noise. The objective of this paper is to develope a fiber optic accelerometer applicable to third party damage detection system. A fiber optic accelerometer was developed by use of combining principles of one degree of freedom vibration model and an extrinsic Fabry-Perot interferometer. The developed fiber optic accelerometer was designed to perform with a sensitivity of 0.06mVg, a frequency range of less than 6kHz and an amplitude range of -200g to 200g. The developed, accelerometer was compared with a piezoelectric accelerometer and calibrated. In order to verify the developed accelerometer, the field experiment was performed. From the field experiment, vibration signals and the location of impact were successfully detected. The developed accelerometer is expected to be used for the third party damage detection system which requires long distance transmission of signals.

A Stabilisation Scheme of a Stepping Motor for a Fiber Optic Gyrocompass System (광파이버 자이로콤파스 시스템을 위한 스텝핑모터의 안정화)

  • Kwon, Yong-Soo;Jung, Sam
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.152-154
    • /
    • 1997
  • This paper describes a study of a stabilisation scheme of a stepping motor in the driving systems of the Fiber Optic Gyrocompass absolutely required a constant speed and a precise position control with fine step angle. The new stabilisation scheme combining microstepping control and frequency modulation is developed which enables the experimental machine to be capable of stable running to a stepping frequency in the range 5 times the open-loop stall frequency.

  • PDF