DOI QR코드

DOI QR Code

Measurement of Spatial Resolution in Fiber-optic Image Guides

  • Received : 2000.06.21
  • Published : 2001.06.01

Abstract

Common methods of determining the spatial resolution of fiber-optic image guides are by measuring the diameter of individual microfibers or by the use of a resolution test target. However these methods cannot provide enough information of spatial resolution in ultrathin fiber-optic image guides. In this study, a simple method to measure the modulation transfer function (MTF) of an mage guide was developed. The MTFs of ultrathin image guides with 3 and 4${\mu}{\textrm}{m}$ Um diameter were measured by examining transmitted sharp edge image. This method should be especially useful for measuring spatial resolution of ultrahigh resolution image guides with less than 5 ${\mu}{\textrm}{m}$ diameter microfibers because their spatial resolution cannot be determined by individual microfiber diameter due to crosstalk and leaky ray phenomena.

Keywords

References

  1. B. Lee, Ph.D. dissertation, University of Florida, 95 (1999)
  2. N. S. Kapany, Fiber optics: Principles and applications, (Academic Press, New York, 1967)
  3. F. Suzuki, Proc. SPIE 1592, 150 (1991) https://doi.org/10.1117/12.51002
  4. L. Huang and U. Osterberg, Proc. SPIE 2536, 480 (1995) https://doi.org/10.1117/12.218456
  5. A. Komiyama and M. Hashimoto, Electron. Lett. 25, 1105 (1989) https://doi.org/10.1049/el:19890737
  6. S. Yamaguchi, A. Shimogima, and T. Hosono, Electro. Comm. Japan, Part 2, 72, 51 (1989)
  7. R. Conde, C. Depeursinge, O. Coquoz, and F. Taleblou, Proc. SPIE 2084, 87 (1994) https://doi.org/10.1117/12.167290
  8. T. Tsumanuma, K. Tanaka, S. Chigira, K. Sanada, and K. Inada Opt. Fib. Medicine 3, Proc. SPIE 906, 92 (1988)

Cited by

  1. Evaluation of optical properties for the development of high resolution ophthalmic endoscope vol.15, pp.5, 2004, https://doi.org/10.3807/KJOP.2004.15.5.429
  2. Optimized Optomechanical Anti-Aliasing Filter for Digital Camera Photography vol.19, pp.5, 2015, https://doi.org/10.3807/JOSK.2015.19.5.456
  3. Development of a flexible variable-view angioscopy system using face-angled GRIN lenses to enhance field of vision vol.263, 2017, https://doi.org/10.1016/j.sna.2017.06.015
  4. Feasibility study on the development of a fiber-optic gamma imaging probe vol.67, pp.1, 2015, https://doi.org/10.3938/jkps.67.175
  5. Evaluation Methods for Medical Endoscope's Characteristics vol.462-463, pp.1662-7482, 2013, https://doi.org/10.4028/www.scientific.net/AMM.462-463.326
  6. Comparison of Optical and Scintillation Images Obtained by Using a Fiber-Optic Beta/Gamma Imaging Detector vol.1083, pp.1662-8985, 2015, https://doi.org/10.4028/www.scientific.net/AMR.1083.137