• Title/Summary/Keyword: a accelerometer

Search Result 1,047, Processing Time 0.033 seconds

Effects of Close Kinetic Chain Resistant Exercise of Lower Extremity on the Gait with Stroke (닫힌 사슬 하지 저항운동이 뇌졸중 환자의 보행에 미치는 영향)

  • Moon, Sang-Hun;Kim, Young-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.475-483
    • /
    • 2014
  • PURPOSE: The purpose of the study was to determine the effects of close kinetic chain resistant exercise of lower extremity on the gait with stroke patients. METHODS: The subjects were 50 patients who were diagnosed with cerebrovascular accident. They were randomly assigned either to a close kinetic chain resistant exercise of lower extremity group (study group)(n=25) or open kinetic chain resistant exercise of lower extremity exercise group (control group)(n=25). Gait abilities were measured by using Timed Up & Go (TUG) test, Functional Gait Assessment (FGA) and spatio-temporal gait variable that were velocity, cadence, stride length, double limb support by 3 axises wireless accelerometer and sway angle of center of mass by same instrument. RESULTS: Study group and control group before and after the intervention there were significantly difference in TUG, FGA, spatio-temporal gait variables and sway angle of center of mass (p<.05). There were significantly different between study group and control group for all variables at post-exercise. CONCLUSION: When all is said and done it is expected to be used as a method for the treatment and prevention in the process of rehabilitation of patients with stroke. In its final analysis when applying resistant exercise of lower extremity to stroke patients' gait, close kinetic chain is more effective than open kinetic chain.

Compensation Method of Gyro Bias Hysteresis Error using the Rate of Temperature (온도 변화율을 이용한 자이로 바이어스 히스테리시스 오차 보상 기법)

  • Yu, Haesung;Kim, Cheon Joong;Sung, Changgi;Lee, Inseop;Park, SangEun;Park, Heung-won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.109-114
    • /
    • 2015
  • A method to compensate a bias hysteresis error of the ring laser gyro using the rate of temperature is proposed in this paper. Until now, we generally have measured and compensated the error of gyro and accelerometer using the temperature. However, we utilize the measured values of the temperature dependent error elements on the temperature rate in navigation system level. We show through experiments that the proposed method can improve the navigation performance and be very effective.

A Study on the Measurement of the Pipeline Displacement Vibration Using Accelerometers (가속도계를 이용한 배관 변위 진동 계측에 관한 연구)

  • Suh, Jin Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.476-482
    • /
    • 2014
  • The stress analysis of the pipeline is required in any kind of plant for its safe operation. For this, the displacement vibration data measured at many locations of the pipeline should be provided. In reality, the installation of the non-contact type displacement sensors such as laser displacement sensors or eddy current type proximity sensors in a narrow and confined region in the vicinity of the pipeline is almost impracticable. In this work, the general purpose piezo-ceramic accelerometers were attached on the measuring points on the pipeline and the acceleration vibration signal was acquired. The measured acceleration signal was low pass filtered and then downsampled. The resulting acceleration signal was transformed into both the time-domain and frequency-domain displacement signal utilizing the fast Fourier transform techniques. All the procedures are presented in detail. It is demonstrated that the measurement of the pipeline acceleration by using contact type accelerometers can be made for the purpose of providing the required displacement data for the stress analysis of the pipeline.

The development of fall detection system using 3-axis acceleration sensor and tilt sensor (3축 가속도센서와 기울기 센서를 이용한 낙상감지시스템 개발)

  • Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.4
    • /
    • pp.19-24
    • /
    • 2013
  • The problem of elderly people with weak physical health has become a very important issue in the aging society. Elderly people with very low judgment and decision-making skills often falls because of the degradation of the strength and balance. Due to the fall triggered off fractures, parenchyma damage, and casualties, generally fast emergency treatment is needed. In this paper, an automatic fall detection system consisting of a triaxial accelerometer and tilt sensor. Using the fall system, the performance of the system was analyzed in many situations. The experimental results showed more than 92% analytical skills.

Correction Algorithm for PDR Performance Improvement through Smartphone Motion Sensors (보행자 추측 항법 성능 향상을 위한 스마트폰 전용 모션 센서 보정 알고리즘)

  • Kim, Do Yun;Choi, Lynn
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.3
    • /
    • pp.148-155
    • /
    • 2017
  • In this paper, we develop a new system to estimate the step count for a smartphone user. The system analyzes data obtained from the accelerometer, magnetic sensor, and gyroscope of an android smartphone to extract pattern information of human steps. We conduct an experiment and evaluation to confirm that the proposed system successfully estimates the number of steps with 96% accuracy when hand-held and 95.5% accuracy when in-pocket. In addition, we found that detection errors were caused by human motions such as touching the screen, shaking the device up and down, sitting up and sitting down, and waving the phone around.

The Wheeled Inverted Pendulum Mobile Robot Control Using Gyroscope and Accelerometer Sensor (자이로와 가속도 센서를 이용한 차륜형 도립진자 이동로봇 제어)

  • Yu, Hwan-Shin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.703-708
    • /
    • 2012
  • This paper proposes the improvement of control performance in the wheeled inverted mobile robot system. and describes the modeling of a wheeled inverted pendulum type mobile robot driven by two different wheels for the position and velocity control. The system is sensitive on the parameter variation, therefore control signal should change to maintain desired state of the system in every instant. we designed proportional-plus-integral controller for our system, After linearization, the system was still unstable, throughout stability analysis of the system, we designed the values of the gains of a proportional-plus-integral controller. From the experimental results, we can find that the performance of the proposed method is better than of the manual tuning method.

Development of Piezoelectric Accelerometers and Their Performance Evaluation (압전형 가속도 센서의 개발과 특성평가에 관한 연구)

  • 이두희;임병덕;이용봉;김정태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.811-818
    • /
    • 1992
  • The sensor technology has becoming emerging area as the automation process in industry requires higher productivity, better quality, and the reliability. In this research, the dynamic measuring sensor such as piezoelectric accelerometers has been developed. Especially, the research concentrates on a design methodology, an analysis of the structural characteristics, and a method of the performance evaluation. The fabricated piezoelectric accelerometers show that the performance characteristics is better than commercial products available in the current market.

Integrated Monitoring System of Maglev Guideway based on FBG Sensing System (FBG 센서 기반의 자기부상열차 통합 모니터링 시스템)

  • Chung, Won-Seok;Kang, Dong-Hoon;Yeo, In-Ho;Lee, Jun-S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.761-765
    • /
    • 2008
  • This study presents an effective methodology on integrated monitoring system for a maglev guideway using WDM-based FBG sensors. The measuring quantities include both local and global quantities of the guideway response, such as stains, curvatures, and vertical deflections. The strains are directly measured from multiplexed FBG sensors at various locations of the test bridge followed by curvature calculations based on the plane section assumption. Vertical deflections are then estimated using the Bernoulli beam theory and regression analysis. Frequency contents obtained from the proposed method are compared with those from a conventional accelerometer. Verification tests were conducted on the newly-developed Korean Maglev test track. It has been shown that good agreement between the measured deflection and the estimated deflection is achieved. The difference between the two peak displacements was only 3.5% in maximum and the correlations between data from two sensing systems are overall very good. This confirms that the proposed technique is capable of tracing the dynamic behavior of the maglev guideway with an acceptable accuracy. Furthermore, it is expected that the proposed scheme provides an effective tool for monitoring the behavior of the maglev guideway structures without electro magnetic interference.

  • PDF

Best Use of the Measured Earthquake Data (지진관측자료의 효과적인 활용에 관한 고찰)

  • 연관희;박동희;김성주;최원학;장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.36-43
    • /
    • 2001
  • In Korea, we are absolutely short of earthquake data in good quality from moderate and large earthquakes, which are needed fur the study of strong ground motion characteristics. This means that the best use of the available data is needed far the time being. In this respect, several methods are suggested in this paper, which can be applied in the process of data selection and analysis. First, it is shown that the calibration status of seismic stations can be easily checked by comparing the spectra from accelerometer and velocity sensor both of which are located at the same location. Secondly, it is recommended that S/N ratio in the frequency domain should be checked before discarding the data by only look of the data in time domain. Thirdly, the saturated earthquake data caused by ground motion level exceeding the detection limit of a seismograph are considered to see if such data can be used for spectrum analysis by performing numerical simulation. The result reveals that the saturated data can still be used within the dominant frequency range according to the levels of saturation. Finally, a technique to minimize the window effect that distorts the low frequency spectrum is suggested. This technique involves detrending in displacement domain once the displacement data are obtained by integration of low frequency components of the original data in time domain. Especially, the low frequency component can be separated by using discrete wavelet transform among many alternatives. All of these methods mentioned above may increase the available earthquake data and frequency range.

  • PDF

Research and Design of Smart Phone Sensor-based Context-aware System (스마트폰 센서 기반 상황인식 시스템 연구 및 설계)

  • Yoon, TaiHa;Yoon, Sungwook;Ko, Jooyoung;Kim, Hyenki
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.3
    • /
    • pp.408-418
    • /
    • 2015
  • This paper describes the design and implementation of situation recognition system with smart phone sensors, which recognizes the dangerous situation at anytime, anywhere through intuitive data analysis of the combination of the sensor. The implemented system consists of wearable heart rate sensor and acceleration sensor of smart phone instead of existing sensor that is attached to the body. It is also designed to get more effective results of recognition about the dangerous situation using merged displacement values of acceleration sensor and heart rate sensor which are measured in the process of recognizing dangerous situations. This research, in accordance with the wide penetration of smartphones, achieves the fast status determination through the combination of an acceleration sensor and a heart rate sensor applied to its own status perception algorithm for anyone who needs the stable perception of risk without the need for a separate provision of the sensor.