• Title/Summary/Keyword: a DTS

Search Result 75, Processing Time 0.023 seconds

The Structure Of The New EMS in KEPCO (한국전력공사의 차세대 EMS 구상)

  • Yu, Sung-Chul;Kim, Chung-Kil;Kim, Jae-Ki;Lee, In-Kyu;Kim, Sung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.893-895
    • /
    • 1996
  • This paper presents the concept of the structure and major functions for the new EMS in KEPCO. This system will be in operation in the beginning of the 21 century in compliance with power system expansion and system architecture consists of distributed and open computer technology. The transmission operation control center as a back-up control center of NCC will control under 345kV transmission system and regional control centers.

  • PDF

The Relationship between Somatic Symptoms and the Trauma-Related Characteristics of Patients with PTSD : A Korean Multicenter Study (다기관 모집 외상 후 스트레스장애 환자에서 외상의 특성과 신체적 증상과의 관계)

  • Shin, Jae-Ho;Choi, Kyeong-Sook;Chae, Jeong-Ho;Woo, Jong-Min;Chee, Ik-Seung;Kim, Jung-Bum;Jeong, Mun-Yong
    • Anxiety and mood
    • /
    • v.4 no.1
    • /
    • pp.34-41
    • /
    • 2008
  • Objective : The aim of this study is to examine the characteristics of somatic symptoms in patients with PTSD according to trauma type. Methods : The subjects of this study were 84 patients diagnosed with PTSD according to the DSM-IVTR and CAPS criteria. The subjects ranged in age from 18 to 76 years, and they were recruited from 18 hospitals across the nation. All participants were asked about their trauma history, and they all completed the Davidson Trauma Scale (DTS), Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), Impact of Event Scale-Revised (IES-R) and Korean-Physical Somatic Symptom Inventory (K-PSI). The items of the K-PSI were categorized into 5 groups according to organ system, and the participants were classified into 6 groups according to trauma type. We compared the results of the social demographical scale, DTS, BDI, STAI, IES-R and each recategorized subscale of the K-PSI among the six groups. Results : There were significant differences between the 6 groups in terms of the Korean-Physical Somatic Symptom Inventory scores for each organ system, except for the cardiopulmonary system, as well as the BDI scores. Post hoc analysis revealed differences between the combat-related trauma group and all other groups but not among any of the other groups. Conclusion : Our result showed that there were significant differences in the somatic symptom scores among the 6 trauma groups. However, patient age and the time elapsed since the traumatic event may have hada crucial influence on the result of this study.

  • PDF

A Study on the Vibration Damping of a Barrel Using Vibration Absorber (동흡진기를 이용한 포신의 진동감쇠에 대한 연구)

  • Kwag, Dong-Gi;Bae, Jae-Sung;Hwang, Jai-Hyuk;Kim, Hun-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.408-415
    • /
    • 2011
  • Advanced tanks in the future combat system are expected to have the trends of large caliber, high explosive shell and light weight for destructive power and improvement in mobility. Their guns are required to have longer barrels to meet increased muzzle exit velocities. However, as the length of the barrel is extended, the vibrations induced by the breech forces in fire and the terrain lead to increased muzzle pointing errors. Therefore, the fire-induced and terrain-induced vibrations must be attenuated. A method to reduce these vibrations without the significant increase of the gun mass is to use the forward thermal shroud as part of a tuned mass damper. In this study, the dynamically-tuned-shroud using this shroud and leaf springs is introduced and its effectiveness on the vibration attenuations of the barrel are verified. The parametric studies on the stiffness of these leaf springs are performed and the analytical results are verified using the experimental model of the dynamically-tuned-shroud.

Conceptual Design for Underground Hydrogen Pipeline Monitoring System: Case Study on Fiber Optic Sensing (지하매설 수소 배관망 안전 모니터링 시스템의 개념 설계: 광섬유 기반 모니터링 사례를 중심으로)

  • Park, Jae-Woo;Yeom, Dong-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.673-686
    • /
    • 2022
  • Recently, as the importance of eco-friendly energy has increased hydrogen gas is in the spotlight as future energy. Due to its special properties, hydrogen gas is more difficult to detect requiring more precise sensing technology. The primary objective of this study is to design a concept of an underground hydrogen pipeline monitoring system. For this, the following research works are conducted sequentially; 1)selection of core technology for conceptual design, 2)state-of-the-art review, 3)design of a concept of the system. As a result, DAS(Distributed Acoustic Sensing), and DTS(Distributed Temperature Sensing) are selected as each core technology. Furthermore, a conceptual design of an underground hydrogen pipeline monitoring system is deducted. It is expected that the impact on the eco-friendly energy industry will be enormous due to the increasing interest in using hydrogen energy.

The Analysis of Muscle Activities on the Lower Limb during Wearing Functional Insole (다기능성 인솔 착용 시 하지의 근활성도 분석)

  • Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.327-336
    • /
    • 2010
  • The purpose of this study was to analyze muscle activities on functional insole with diet effect. Originally, ten healthy female subjects with an average age of 23.2 year(S.D=1.1), weight of 49.7 kg(S.D=4.9), height of 163.2 cm(S.D=3.5) and a shoe size of 237.5 cm(S.D=4.9) were participated in this experiment. Ten healthy females walked on a treadmill(speed=about 4.2 km/h) wearing two different insole types. Muscle activities data was collected using the EMG operating system. The surface EMG signal for tibialis anterior(TA), gastrocnemius(GA), vatus lateralis(VL) and biceps femoris(BF) were acquired at the RMS(10 Hz, 350 Hz) using Noraxon Telemyo DTS system(Noraxon inc, USA). This study processed the data using the Windows SPSS ver.17.0 to get an independent t-test, with the setting, p<.05. Analysis of muscle activity were measured and calculated during walking. The results are as follow: Functional insole wearing were increased muscle activities significantly from Tibialis anterior(TA) during total gait cycle. Normal distribution was demonstrated in total step of stances period. One foot standing position showed decreased muscle activity. Two foot standing position was demonstrated with gastrocnemius and biceps femoris. As a result of the analysis, Functional insole will inerease the diet effect in the use of four muscle groups.

Preparation and Properties of UV-Curable Polyurethane Acrylates(I) -Effect of Molecular Weights of Polyol and Diol with Low Molecular Weight into Polymer Chain- (UV-경화 폴리우레탄 아크릴레이트의 제조와 특성(I) -폴리올의 분자량과 저분자량 디올의 도입의 영향-)

  • 최준영;이동진;김한도
    • Textile Coloration and Finishing
    • /
    • v.11 no.4
    • /
    • pp.1-7
    • /
    • 1999
  • Urethane-acrylate propelymers for secondary coating of optical fiber and high - performance material were prepared from the 4,4'-diphenylmethane diisocyanate(MDI), poly(tetramethylene oxide)glycol(PTMG, Mw 650 or 1000), 1,6-hexanediol(HD), 2-hydroxyethyl acrylate(HEA), and dibutyltin dilaurate as a catalyst. UV-Curable polyurethane acrylates were formulated from the urethane-acrylate prepolymers, three types of reactive diluents(DTs) having mono-, di-, and trifunctional-phenoxyethyl acrylate(PEA), hexanediol diacrylate(HDDA), and trimethylolpropane triacrylate(TMPTA), and 1-hydtoxycyclohexyl phenyl ketone(Irgacure 184) as a photoinitiator. The UV-cured films of polyurethane acrylates were obtained by curing using a medium-pressure mercury lamp(U W/cm, $\lambda_{max}=365\;nm)$. In this work, the effects of molecular weights of polyol and diol with low molecular weight into polymer chain on mechanical and dynamic mechanical properties of UV-cured polyurethane acrylates were studied. The structure and properties of the films obtained from the UV photopolymerization of urethane-acrylate prepolymer were investigated by FT-IR spectroscopy, dynamic mechanical measurement, tensile testing, and X-ray diffractometry.

  • PDF

Demystifying the Definition of Digital Twin for Built Environment

  • Davari, Saman;Shahinmoghadam, Mehrzad;Motamedi, Ali;Poirier, Erik
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1122-1129
    • /
    • 2022
  • The concept of Digital Twin (DT) has been receiving an increasing amount of attention in the construction management and building engineering research domains. Although the benefits of DT are evident, confusion with regards to the concept of DTs and its relationship with others such as Cyber-Physical Systems (CPS), Building Information Modelling (BIM) and Internet of Things (IoT) remains. This paper aims to help allay this confusion through an in-depth analysis of the definition of DT and its unique characteristics. As such, a review of the past and current definitions of DT and CPS in various domains is performed. An analysis is then conducted to identify the overlaps between the definition of DT with CPS, as well as with BIM and IoT. Finally, given the relatively closer resemblances between DT and CPS, a set of four distinct dimensions enabling their comparative analysis and highlighting their shared and unique characteristics is discussed. This paper contributes to the existing literature by exploring the definition of DT and presenting two original conceptualizations that help further refine the concept of DT in the construction and management and building engineering domain.

  • PDF

Ultimate bearing capacity of conical shell foundations

  • Colmenares, J.E.;Kang, So-Ra;Shin, Young-Jin;Shin, Jong-Ho
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.507-523
    • /
    • 2014
  • Shell foundations have been employed as an alternative for the conventional flat shallow foundations and have proven to provide economical advantage. They have shown considerably improved performance in terms of ultimate capacity and settlement characteristics. However, despite conical shell foundations are frequently used in industry, the theoretical solutions for bearing capacity of these footings are available for only triangular shell strip foundations. The benefits in design aspects can be achieved through theoretical solutions considering shell geometry. The engineering behavior of a conical shell foundation on mixed soils was investigated experimentally and theoretically in this study. The failure mechanism was obtained by conducting laboratory model tests. Based on that, the theoretical solution of bearing capacity was developed and validated with experimental results, in terms of the internal angle of the cone. In comparison to the circular flat foundation, the results show 15% increase of ultimate load and 51% decrease of settlement at an angle of intersection of $120^{\circ}$. Based on the results, the design chart of modified bearing capacity coefficients for conical shell foundation is proposed.

Biomechanical Analysis of Trail Running Shoes Applied to Korean Shoe-Lasts (한국인 족형을 적용한 트레일 러닝화의 생체역학적 분석)

  • Park, Seung-Bum;Lee, Kyung-Deuk;Kim, Dae-Woong;Yoo, Jung-Hyeon;Kim, Kyung-Hun;An, Chang-Shin;Lee, Tae-Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.221-230
    • /
    • 2010
  • The purpose of this study was to analyze biomechanical factors of trail running shoes applied to korean shoe-lasts. 10 healthy male subjects with an average age of 37.2 years(SD=8.28), weight of 69.6 kg(SD=10.56) and a height of 171 cm(SD=4.93) were recruited for this study. Ten males walked on a treadmill wearing four different shoes. Foot pressure data was collected using a Pedar-X mobile system(Novel Gmbh., Germany) operating at the 1000 Hz. Surface EMG signals for tibialis anterior, gastrocnemius, vastus lateralis and biceps femoris were acquired at 1000 Hz using Noraxon TeleMyo DTS system(Noraxon Inc., USA). Foot pressure and leg muscle fatigue were measured and calculated during walking. The results are as follows: After walking 60 minutes, Type A showed a lower MPF. MPF values were significantly different from each muscle(p<.05). Therefore, Type A shoe might decrease muscle fatigue in the legs while walking. In addition, Type It showed that Type A shoe has the highest contact area and the lowest maximum pressure. As a result of the analysis, Trail running shoes will use a new design to reduce muscle fatigue and are expected to increase comfort and fitting.

The Effects of Abdominal Drawing-in on Muscle Activity in the Trunk and Legs during Ramp Walking (경사로 보행 시 복부 드로잉-인 기법이 몸통 및 다리의 근활성도에 미치는 영향)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.137-144
    • /
    • 2019
  • Purpose: This study examined the effects of the abdominal drawing-in maneuver (ADIM) on muscle activity in the trunk and legs while subjects walk on a ramp. Methods: The subjects were healthy adult males (n=15) and females (n=8) in their twenties. The subjects were asked to maintain the ADIM contraction for 15 minutes using a pressure biofeedback unit. Their muscle activity was then measured while ascending or descending the ramp with or without the ADIM contraction maintained. Activity in the sternocleidomastoid, splenius capitis, rectus abdominis, external oblique abdominal, transversus abdominis, erector spinae, vastus medialis, and vastus lateralis muscles was measured using surface electromyography (TM DTS, Noraxon, USA). A paired t-test was conducted using SPSS 18.0 (IBM) for statistical data processing. Results: Maintaining the ADIM contraction during ascension led to a significant increase (p<0.05) in muscle activity for the rectus abdominis, transversus abdominis, vastus medialis, and vastus lateralis, but a significant decrease (p<0.05) in muscle activity for the erector spinae, when compared to the same activity without the ADIM maintained. Furthermore, maintaining the ADIM contraction during descent led to a significant increase (p<0.05) in muscle activity for the rectus abdominis, external abdominal oblique, transversus abdominis, vastus medialis, and vastus lateralis, but a significant decrease (p<0.05) in muscle activity for the erector spinae, when compared to the same activity without the ADIM maintained. Conclusion: As a result of this study, it maintains the ADIM and reduces lumbar muscle activity at the waist and increases muscle activity in the legs when walking on a ramp. Therefore, maintaining the ADIM contraction during ramp walking is recommended as training to improve the function of patients' muscular skeleton.