Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가)

  • Cho, Han-Goo;Yun, Han-Soo;Kim, Seok-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, You-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

The study on surge detector of digital surge counter for arrester (Arrester용 digital surge counter의 서지 검출 장치에 관한 연구)

  • Kim, Seok-Sou;Choi, Ike-Sun;Cho, Dong-Hwan;Lee, Kang-Sup;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.170-174
    • /
    • 2005
  • The purpose of this study is to design the digital surge counter for lightning arresters. The used detecting method for surges is using the signal of both ends of ZnO varistor. The electronic detecting parts of the digital counter are arranged in outside of main processer for protecting it from noise. The detecting parts change detected signals into small signals. The countermeasures for noises are (1) Shielding (2) Reinforcement of power circuits (3) Cables & Circ1e core (4) Watch-doc & control of input signals.

  • PDF

Contruction and Performance Evaluation of the Surge Arrester for Transmission Class (송전급 피뢰기의 구조와 성능평가)

  • Kim, S.S.;Choi, I.S.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.890-893
    • /
    • 2002
  • Since 1970s, varistors using metal-oxide resistors have been applied to Gapless surge arresters for power system. In the paper, the structure of metal-oxide surge arresters without gaps for 362kV GIS which is developed the first in korea has been introduced. And the main evaluation items for the metal-oxide resistors which are reference voltage test, residual voltage test, long duration current impulse withstand test and operating duty test is tested and evaluated.

  • PDF

AC Accelerated Ageing Characteristics of Zinc Oxide Varistors for the Station Class Lightning Surge Arresters (발변전급 피뢰기용 산화아연소자의 AC 가속열화특성)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Han, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.315-316
    • /
    • 2005
  • This paper describes the AC accelerated ageing characteristics of zinc oxide varistors for the station class lightning surge arresters. ZnO varistors whose rated voltage were 3.27kV, 4.00kV, and 6.00kV were manufactured with general ceramic production methods. The power loss of sample A varistors rapidly increased and eventually showing the thermal run-away, but sample B and sample C varistors exhibited negative creep phenomena in power losses during the test.

  • PDF

A Study on the Best Selection of Lightning Arrester for DC Electric Traction Vehicles (직류전동차 탑재용 피뢰기의 최적선정에 관한 연구)

  • Cha, Myung-Soo;Song, Jae-Yong;Kim, Il-Kwon;Kil, Gyung-Suk;Lee, Dae-Sung;Park, Jae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1519-1520
    • /
    • 2006
  • This paper describes a selection and application recommendations of ZnO arresters on DC electric traction vehicles. We measured and analyzed the system voltages applied to arresters and the surge currents flowing arresters on DC electric traction vehicles under operation to decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_R$), and the Nominal Discharge Current($I_n$). System voltages measured up to 1,800 V during anti-breaking in 1,500 V-system, and surge currents were recorded up to 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and the standard EN50163, we proposed the Continuous Operating Voltage($U_C$) the Rated Voltage($U_R$) for the $1,500V_{dc}$ electric traction vehicles.

  • PDF

Evaluation of Electrical Characteristics of Metal Oxide Varistors for Surge Arresters (초고압용 피뢰기 산화아연소자의 전기적 특성 평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Han, Se-won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.46-49
    • /
    • 2005
  • This paper presents the electrical characteristics of metal oxide varistors for lightning surge arresters. ZnO varistors were fabricated with typical ceramic production methods and two types of varistors were also prepared to be compared. The nominal discharge current and line discharge class of those varistors are $10kA(8/20{\mu}s)$ and class 3, respectively. The diameter of varistors manufactured and prepared were in the range of 61.6~65.0mm and the thickness of those were in the range of 27~42.52mm. The reference and residual voltage were tested and reference and residual voltage per 1mm and the ratio of reference and residual voltage were calculated. The reference voltage per 1mm of varistors manufactured was about 175V/mm but that of A's and B's varistors was nearly 200V/mm. The residual voltage exhibited the same trends as the reference voltage, so the reference and residual voltage per 1mm of domestic varistors should be increased. According to the results of tests, it is thought that if the reference and residual voltage per 1mm were increased to 200V/mm and 330V/mm, domestic ZnO varistors would be possible to apply to the station class arresters in the near future.