• Title/Summary/Keyword: Zirconia crown

Search Result 151, Processing Time 0.018 seconds

FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS (지르코니아 단일구조 전부도재관의 파절강도)

  • Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

A comparative study on the fracture strength of esthetic porcelain crowns (심미도재관의 파절 강도 비교 연구)

  • Kim, Eun-Ha;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF

An alternative method to convert fractured metal ceramic surveyed crown into a complete contour zirconia surveyed crown using CAD-CAM technology under anticancer treatments: a clinical report (항암치료 중인 환자에서 파절된 금속-도재관을 CAD/CAM으로 제작된 complete contour zirconia surveyed crown(완전한 윤곽을 가진 지르코니아 써베이드 전장관) 보철 수복: 증례 보고)

  • Lee, Seon-Ki;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • In this clinical report, a simple and convenient conversion of a fractured metal-ceramic surveyed crown into a complete contour zirconia surveyed crown by using computer-aided design and computer-aided manufacturing technology for an existing partial removable dental prosthesis is described. The duplication of the original contours, morphology, and the rest seat of the existing metal-ceramic surveyed crown, into a complete contour zirconia surveyed crown under anticancer treatments were reported.

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.

Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth (CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교)

  • Ong, Seung-Hwan;Kim, Jongsoo;Kim, Jongbin;Shin, Jisun;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.205-212
    • /
    • 2020
  • The purpose of this study is to evaluate the validity of primary anterior zirconia crown made with Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology by analyzing fracture strength and translucency parameter. Zirconia crown was designed with CAD software, using 3D scanned data of #61 tooth model. Crown fabrication was performed with CAM machine using zirconia block. Zirconia crowns were divided into 3 groups according to thickness(0.3, 0.5, and 0.7 mm), and fracture strength was compared with 1.0 mm thickness of resin strip crown. The compressive force was applied with universal testing machine at 30° along the incisal edge at increments of 1 mm/min. For translucency evaluation, 0.3, 0.5, and 0.7 mm thickness of zirconia specimens were fabricated and translucency was measured with spectrophotometer. Among zirconia groups, there was a significant increase in fracture strength as thickness increased (p < 0.05). The fracture strength of zirconia crown was significantly higher than resin strip crown in all groups (p < 0.05). Translucency parameter was highest in 0.3 mm group, and significantly decreased as thickness increased to 0.5 and 0.7 mm (p < 0.05). Thin primary anterior zirconia crown can be designed and fabricated according to individual needs by using CAD/CAM. Restoration with thin crown would reduce the amount of tooth reduction, risk of pulp exposure, and make more esthetic restoration possible.

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

Evaluation of Color Change According to Coloring Time of Dental Zirconia Block (치과용 지르코니아 블럭의 착색시간에 따른 색조변화 관찰)

  • Choi, Sung-Min;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.219-224
    • /
    • 2011
  • Purpose: The current study focused on investigating color change of dental zirconia block with respect to the block coloring time. Methods: Three types of dental zirconia blocks(Zirtooth, Pearl-HT, D-Max) were tinted with coloring agent under four different time condition (0 minutes, 1 minutes, 10 minutes, 30 minutes). The quantitative evaluation of the tinted dental zirconia blocks was conducted with spectrophotometer. Results: The Zirtooth and D-Max blocks showed lower H value. The Pearl-HT blocks showed poor reflectivity(L value). Conclusion: The study of color change of zirconia block, which consists the substructure of all ceramic Crown, is applicable for deciding appropriate coloring condition when fabricating one layer ceramic Crown or double layer ceramic Crown.

FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING (지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교)

  • Lee, Sang-Min;Jeong, Hee-Chan;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.12-20
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis

  • Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Lee, Hyeonjong;Kim, Hyeong-Seob
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.329-332
    • /
    • 2016
  • Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.