• Title/Summary/Keyword: Zero

Search Result 9,222, Processing Time 0.039 seconds

Design of Format Conversion Filters for MPEG-4 (MPEG-4를 위한 포맷 변환 필터의 설계)

  • Jo, Nam Ik;Kim, Gi Cheol;Yu, Ha Yeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.637-637
    • /
    • 1997
  • In this paper, format conversion filters are proposed, which have advantages in hardware implementation compared to the ones proposed in MPEG-4 Video Verification Model. since each coefficients of the proposed filters is constrained to have less than two non-zero digits in minimal signed digit representation, multiplication of input and the coefficient can be implemented by a single adder. As a result, the proposed filters have advantages in hardware complexity and speed, compared to the filters which are usually implemented by integer multiplier or carry save adders. Six kinds of filters are proposed in MPEG-4 Video Verification Model for size conversion of 2:1, 4:1, 5:3 and 5:6. We design 5 filters for the same purpose and compare the performance. The remaining one is very simple to implement. For comparing the filtering performance, we first compare the results of sine wave frequency conversion as an indirect but meaningful comparison. Second. We compute the PSNR of the images obtained from the proposed filters and the ones proposed by MPEG, with reference to the images obtained by using double precision arithmetic and high order filter. The results show that the performance of the proposed filters is almost the same as that of the filters proposed by MPEG. In conclusion, the peroformance of the proposed filters is comparable to that of the ones in MPEG-4, while requiring lower hardware complexity and providing high operating speed.

Development of the Calorimeter to Measure Heat Rate Generated from Battery for EV & HEV (전기자동차용 축전지의 발열량 측정을 위한 열용량계 개발)

  • Yang Cheol-Nam;Park Seong-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.218-220
    • /
    • 1999
  • The performance of the Electric Vehicle and Hybrid Electric Vehicle depends on that of the battery pack composed of series connected batteries. And thermal property is one of the main factors which decide the performance of the battery pack. So heat generation rate from the battery under the various driving mode must be measured as precise as possible because thermal characteristics of the battery affect the driving performance and battery pack's life cycle. Besides, to design and develop the battery thermal management system for the EV and HEV, the measurements of the thermal properties of the batteries are needed. However, the established calorimeter is not adequate to test an EV's battery because its cavity is too small to accommodate the EV's battery. Therefore we developed the calorimeter to test the thermal property of the EV's battery. Its cavity size is 120mm long, 75mm wide and 200mm high. The calorimeter is calibrated by the dummy cell which generates the heat rate from zero to 200W. The measuring accuracy of the calorimeter is within $2\%$ and its voltage stability is 2.5mV in the constant temperature bath.

Photoeletrochemical Properties of α-Fe2O3 Film Deposited on ITO Prepared by Cathodic Electrodeposition (음극전착법을 이용한 α-Fe2O3 막의 광전기화학적특성)

  • 이은호;주오심;정광덕;최승철
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.842-848
    • /
    • 2003
  • Semiconducting $\alpha$-Fe$_2$O$_3$ film was prepared by the cathodic electrodeposition method on Indium Tin Oxide (ITO) substrate for photoelectrochemical cell application. After heat treatment at 50$0^{\circ}C$, the phase was changed from Fe to $\alpha$-Fe$_2$O$_3$. The phase, morphology, absorbance, and photocurrent density (A/$\textrm{cm}^2$) of the film depended on the preparation conditions: deposition time, applied voltage, and the duration of heat treatment. The $\alpha$-Fe$_2$O$_3$ film was characterized by X-Ray Diffractometer (XRD), Scanning Electron Microscope (SEM), and UV -Visible Spectrophotometer. The stability of the $\alpha$-Fe$_2$O$_3$ film in aqueous solution was tested at zero bias potential under the white-light source of 100 mW/$\textrm{cm}^2$. The apparent grain size of the films formed at -2.0 V was larger than that grown at -2.5 V. The $\alpha$-Fe$_2$O$_3$ film deposited at -2.0 V for 180 s and heat-treated at 50$0^{\circ}C$ for 1 h showed the predominant photocurrent of 834$\mu$A/$\textrm{cm}^2$.

Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation : Influence of wall Motion, Impedance Phase Angle, and non-Newtonian fluid (복부대동맥 분기관에서의 벽면전단응력 분포 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choi J.H.;Kim C.J.;Lee C.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.261-271
    • /
    • 2000
  • The present study investigated flow dynamics of a two-dimensional abdominal aortic bifurcation model under sinusoidal flow conditions considering wall motion. impedance phase angle(time delay between pressure and flow waveforms), and non-Newtonian fluid using computational fluid dynamics. The wall shear stress showed large variations in the bifurcated region and the wall motion reduced amplitude of wall shear stress significantly. As the impedance phase angle was changed to more negative values, the mean wall shear stress (time-averaged) decreased while the amplitude (oscillatory) of wall shear stress increased. At the curvature site on the outer wall where the mean wall shear stress approached zero. influence of the phase angle was relatively large. The mean wall shear stress decreased by $50\%$ in the $-90^{\circ}$ phase angle (flow wave advanced pressure wave by a quarter period) compared to the $0^{\circ}$ phase angle while the amplitude of wall shear stress increased by $15\%$. Therefore, hypertensive patients who tend to have large negative phase angles become more vulnerable to atherosclerosis according to the low and oscillatory shear stress theory because of the reduced mean and the increased oscillatory wall shear stresses. Non-Newtonian characteristics of fluid substantially increased the mean wall shear stress resulting in a less vulnerable state to atherosclerosis.

  • PDF

Composition of Buckwheat (Fagopyrum esculentum Moench) Cultivars from Korea (한국산 메밀의 성분)

  • Shim, Tae-Heum;Lee, Heok-Hwa;Lee, Sang-Young;Choi, Yong-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1259-1266
    • /
    • 1998
  • To clarify the values and varieties of the buckwheats as a dietary source of nutritional and functional components, thirteen different samples of buckwheat were analyzed for this investigation. Six developed seeds were given by RDA, Korea or RDA branch of Kangwondo, and seven land race seeds were collected from a farmhouse. Amino acid analysis showed that glutamate, arginine and asparagine were major amino acids, whereas tryptophan, methionine and cysteine were minor ones of buckwheat. In addition, tryptophan content of buckwheat cultivars from Korea was 195 mg% on average. The content of rutin tended to be higher in developed cultivars than land races. On the other hand, the contents of phytic acid in buckwheats were in the range of 7.0 to 13.6 mg/g. In the tocopherol homologues of the buckwheats analyzed by HPLC, mean ${\gamma}-tocopherol$ contents were 6.16 mg/100 g with the actual range of $4.67{\sim}8.58\;mg/100g$, whereas ${\beta}-form$ was very low or zero. There were a big variations in the iron content of the buckwheats of the minerals. SDS-PAGE showed that total proteins from buckwheats exhibited a relatively similar electrophoretic patterns on the whole. The results show that CV Suwon 1 has good quality, judged from the distribution of the components of buckwheats analyzed.

  • PDF

Environmental Change of Suspended Sediment Discharge by Human Action (인간활동으로 인한 부유토양유출의 환경변화)

  • 박종관
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.153-160
    • /
    • 1993
  • The problem of supply and transport of sediment from a mountainous catchment is very important in explaining dynamic geomorphology and the hydrological cycle. The discharge of suspended sediment is determined by a morphological system. Human interference to environment Is also an important, not negligible factor in sediment production. Moreover, growing concern in recent years for the problems of nonpoint pollution and for the transport of contaminants through terrestrial and aquatic ecosystems has highlighted the role of sediment-associated transport in fluvial systems. This study was conducted in forested and quarried catchments in order to clarify the different discharge process and the mechanism of suspended sediment dynamics for each catchment. As a forested catchment, the Yamaguchi River catchment which drains a $3.12km^2$ area was chosen. On the other hand, the Futagami River basin which is formed by three subbasins (1.07, 1.59 and $1.78km^2$), as a quarried catchment was selected. These catchments are situated to the north and east of Mt. Tsukuba, Ibaraki, Japan. The discharge pattern of suspended sediment from the Futagami River basin is more unstable and irregular than that from forested catchment, the Yamaguchi River catchment. Under the similar rainstorm conditions, suspended sediment concentration from quarried catchment during a rainstorm event increases from 43 to 27,340 mg/l. However, in the case of the forested catchment it changes only from nearly zero to 274 mg/l. Generally, the supply source of suspended sediment is classified into two areas, the in-channel and non-channel source areas. As a result of field measurements, in the case of the forested catchment the in-channel (channel bed, channel bank and channel margin) is the main source area of suspended sediment. On the other hand, remarkable sediment source area on the Quarried catchment is the non-channel that is unvegetated ground.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Architecture Design of High Performance H.264 CAVLC Encoder Using Optimized Searching Technique (최적화된 탐색기법을 이용한 고성능 H.264/AVC CAVLC 부호화기 구조 설계 기법)

  • Lee, Yang-Bok;Jung, Hong-Kyun;Kim, Chang-Ho;Myung, Je-Jin;Ryoo, Kwang-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.431-435
    • /
    • 2011
  • This paper presents optimized searching technique to improve the performance of H.264/AVC. The proposed CAVLC encoder uses forward and backward searching algorithm to compute the parameters. By zero-block skipping technique and pipelined scheduling, the proposed CAVLC encoder can obtain better performance. The experimental result shows that the proposed architecture needs only 66.6 cycles on average for each $16{\times}16$ macroblock encoding. The proposed architecture improves the performance by 13.8% than that of previous designs. The proposed CAVLC encoder was implemented using VerilogHDL and synthesized with Megnachip $0.18{\mu}m$ standard cell library. The synthesis result shows that the gate count is about 15.6K with 125Mhz clock frequency.

  • PDF

A High Efficiency Power Conversion Circuit with Wide ZVS Range for Large Screen PDP Sustaining Power Module (넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지전원단을 위한 고효율 전력 변환회로)

  • Park Kyung-Hwa;Moon Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.578-586
    • /
    • 2005
  • Recently, due to the launch of digital broadcasting service, the demand of Flat Panel Display (FPD) is sharply rising. Among them, the PDP is expected to be one of the most promising digital displays of next generation because of its large screen size, high resolution, thinness and board field of view. Meanwhile, the PDP uses ADS (Address Display-period Separation) scheme which divide one subfield into address and sustaining period to express the grey scale of images. Since the output of sustaining power module Is mostly used for sustaining period, the load of the sustaining power module can be considered as a pulsating load. Due to this particular load condition, if the wide ZVS range of the power switches is not guaranteed, the hard switching causes large amount of switching loss and serious thermal problem in power module. In this paper, a high efficiency power conversion circuit for 60' PDP sustaining power module which achieves wide ZVS range with the help of additional ZVS tank is proposed. According to the various gating methods, the different operations of the proposed converter are presented. And, to confirm the properties of the proposed converter, an experimental prototype of 900W power converter is constructed md tested. As a result, more than $92\%$ of high efficiency is obtained at $10\%$ load condition, and the ZVS operation is achieved from full load to $10\%$ load condition.

Bioequivalence of Enteric-coated Omeprazole Products (오메프라졸 장용성제제에 대한 생물학적 동등성 평가)

  • Kim, Chong-Kook;Jeong, Eun-Ju;Lee, Eun-Jin;Shin, Hee-Jong;Lee, Won-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 1993
  • The bioequivalence of two omeprazole enteric-coated products was evaluated in 16 normal male volunteers (age 26-32 yr, body weight 57-75 kg) following single oral administration. Test product was enteric-coated KD-182 tablet (Chong Kun Dang Corp., Korea) and reference product was $Rosec^{\circledR}$ capsule containing enteric-coated pellets of omeprazole (Yuhan Corp., Korea). Both products contain 20 mg of omeprazole. One tablet or capsule of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study ($2\;{\times}\;2$ Latin square method). Average drug concetrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products(p>0.05); the area under the concentrationtime curve to last sampling time (8 hr) $(AUC_{0-8hr})$ $(1946.5{\pm}675.3\;vs\;2018.3{\pm}761.6\;ng{\cdot}hr/ml)$, AUC from time zero to infinite $(AUC_{o-\infty})$ $(2288.6{\pm}1212.8\;vs\;2264.9{\pm}1001.3\;ng{\cdot}hr/ml)$, maximum plasma concentration $(C_{max})$ $(772.5{\pm}283.3\;vs\;925.8{\pm}187.7\;ng/ml)$, time to maximum plasma concentration $(T_{max})$ $(2.38{\pm}1.06\;vs\;2.34{\pm}1.09\;hr)$, apparent elimination rate constant $(k_{\ell})$ $(0.5339{\pm}0.2687\;vs\;0.5769 {\pm}0.2184\;hr^{-I})$, apparent absorption rate constant $(k_a)$ $(1.1536{\pm}0.5278\;vs\;0.9739{\pm}0.9507 hr^{-1})$ and mean residence time (MRT) $(3.13{\pm}0.73\;vs \;3.41{\pm}1.04\;hr)$. The differences of mean $(AUC_{0-8hr})$, $C_{max}$, $T_{max}$ and MRT between the two products (3.69, 19.83, 1.32 and 8.99%, respectively) were less than 20%. The power $(1-{\beta})$ and treatment difference $(\triangle)$ for $AUC_{o-8hr}$ $C_{max}$ and MRT were more than 0.8 and less than 0.2, respectively. Although the power for $T_{max}$ was under 0.8, $T_{max}$ of the two products was not significantly different each other(p>0.05). These results suggest that the bioavailability of KD-182 tablet is not significantly different from that of $Rosec^{\circledR}$ capsule. Therefore, two products are bioequivalent based on the current results.

  • PDF