• Title/Summary/Keyword: XLPE Cable

Search Result 316, Processing Time 0.024 seconds

A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material (반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구)

  • Lee, C.Y.;Shin, D.S.;Dudkin, Sergey M.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable. (66kV XLPE Cable용 조립형 접속함의 개발)

  • Oh, E.J.;Kim, K.Y.;Lee, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

The Installation of Prefabricated Joint for 161kV XLPE Cable Underground Transmission Line (161kV XLPE CABLE용 Prefabricated joint의 실선로 적용)

  • Bong, W.K.;Chang, K.W.;Lee, H.S.;Oh, J.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1611-1613
    • /
    • 1998
  • The new type of prefabricated joint for 161kV XLPE cable have been developed. we, LG Cable & Machinery Ltd., made an huge contract with an foreign country's Power company for the supply of cable and accessories, the training of jointing and termination work to local personnel, technical assistance by joint venture and the supervision of installation and commissioning. By the end of 1997, one of several routes under the contract successfully finished being constructed and specially tested on site. In operation, now this underground transmission line proves well the reliability and efficiency of prefabricated joint and termination applied first time in foreign country.

  • PDF

DEVELOPMENT OF 230kV XLPE CABLE & ACCESSORY (230kV XLPE 케이블 및 부속재 인증시험 완료)

  • Kwon, B.I.;Nam, J.S.;Oh, E.J.;Kim, K.Y.;Choi, B.N.;Yun, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2268-2270
    • /
    • 1999
  • The underground transmission line have been consistently developed to increase its voltage level for satisfying the customer's demand through supplying the high reliability power. The underground XLPE cable and its accessories of 500kV level have been already developed internationally, but the XLPE cable have been installed 154kV level in Korea up to now. Thus, our company has developed 230kV XLPE cable and its accessory in 1998 for preparing 345kV level system in Korea and being qualified as international cable maker of developing oversea markets. In this paper, newly our developed 230kV system will be introduced using the type test result according to IEC 840 and additional specification.

  • PDF

Trends of Prefabricated Joints and their Jointing Techniques for EHV XLPE-insulated Power Cables (초고압 XLPE 전력케이블용 Prefabricated Joint 및 접속기술 동향)

  • Kim, Y.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1608-1610
    • /
    • 1998
  • An oil-filled paper-insulated power cable and a XLPE-insulated power cable have been mainly applied as an extra-high-voltage underground power cable. But in recent the XLPE cable has been applied more widely than the OF cable, because of its advantages, such as the low-cost and simple installation. In general two types, molded and prefabricated, of straight joints are applied for the XLPE cables. For a tape-molded joint, one of molded joints, its electrical properties are excellent, but it has some disadvantages, such as a long working time. high skill of workers and the high cost of jointing equipments. For a prefabricated joint, developed and applied in Europe and Japan, its working time is short, its jointing procedures are simple, and its quality control is easy, but its prices are very high. In Korea the development of a compression-type PJ will be finished in the near future, and studies of its jointing techniques and equipments is actively going on. This paper describes the design and construction of the PJ, the jointing procedures and techniques for the PJ, and its future trends.

  • PDF

A theoretical investigation on the temperature distribution of XLPE insulated cable for HV during curing prcess (고압 XLPE 절연 케이블의 가교공정중의 온도분포 계산에 대한 이론적 고찰)

  • Kang, T.O.;Kim, K.S.;Cheon, C.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1229-1231
    • /
    • 1995
  • XLPE cable, which has excellent electrical and thermal performance, has been widely used for HV transmission & distribution lines. The most important thing to produce the cable products having good performance is to set the optimal operating conditions of cable machinery. Because it is very difficult to measure the temperature of cable under curing process practically, it is necessary to evaluate the cable temperature by using the method to simulate real conditions numerically. In this work, We investigate the basic theory on transient heat transfer between curing tube and cable for making a numerical simulation program using computer. In this program, a differential equation is approximated by a infinite differential method and a few assumptions are used to simplify the model and minimize the calculation time of program.

  • PDF

Development of 132kV XLPE Cable Composite Bushing EB-A (132kV XLPE Cable용 Composite Bushing 기중종단접속함 개발)

  • Kim, J.H.;Oh, E.J.;Kim, K.Y.;Park, J.K.;Jeoung, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.547-549
    • /
    • 2000
  • Silicone insulators have many advantages over porcelain insulators. Especially silicone insulators have good characteristics of impact hardness, surface insulation, ease of processing, mass productivity and don't have risk of bombardment and vandalism. Recently insulation part made by silicone are becoming widely used. In this paper we introduce the development of Sealing End for 132kV XLPE cable with silicone composite hollow insulator and the adoption of it to a actual transmission line in abroad. This paper contains of design procedure, structure, electrical performance of it.

  • PDF

Partial Discharge Measurement for 154kV XLPE Cable Line (154kV XLPE 케이블 실선로 부분방전 검출)

  • Kim, C.S.;Lee, J.S.;Kim, J.C.;Park, C.G.;Seok, K.H.;Kim, W.N.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF

Type Test at KEMA for 400kV XLPE Cable and Accessories (400kV XLPE 케이블 시스템의 해외 인증시험)

  • Kim, J.H.;Kang, C.H.;Baik, S.Y.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1028-1030
    • /
    • 1999
  • 전 세계적으로 송전 용량의 증대 요구에 따라 송전 시스템이 초고압화 되어 가고 있으며 환경친화성 및 여러 특성에 있어 OF(Oii filled) 케이블에 비하여 우수한 성능을 지닌 XLPE(Crosslinked Polyethylene) 케이블의 사용이 급속하게 증가하고 있는 추세이다. 최근 345kV급 이상의 XLPE 케이블 시스템 개발이 해외 선진업체들에 의해 활발히 진행되고 있으며 이의 평가를 해외공인 인증기관에서 수행하여 개발된 제품의 디자인 검증 및 장기간 신뢰성을 입증하고 있다. 이러한 추세에 맞추어 LG 전선은 400kV 케이블 및 접속함의 사내 개발시험후 해외공인 인증기관인 네덜란드의 KEMA에서 IEC 62067에 따른 인증시험을 완료하여 개발된 제품의 높은 신뢰성을 인증 받았으며, 자사의 초고압 기술을 한 단계 상승시켜 세계 선진업체들과 경쟁할 수 있는 발판을 마련하였다.

  • PDF

Development of EHV 275KV XLPE Power Cable (초고압 275KV XLPE 케이블의 개발)

  • Kim, J.W.;Kim, H.K.;Park, K.H.;Lee, K.H.;Choi, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.903-906
    • /
    • 1992
  • At present the XLPE insulated power Cables have installed until 154KV level in KOREA. Therefore, our company has developed 275KV XLPE cable as a means 345KV level-up of CV cable as well as exploitation of overseas markets. In this paper, the outline of design standards, manufacturing processes and test performance of 275KV CV cable are described.

  • PDF