• Title/Summary/Keyword: X8

Search Result 8,976, Processing Time 0.038 seconds

Effect of Moisture Content of Biocatalyst on the Gas Phase Continuous Bioreaction (생촉매의 수분함유량이 기상의 연속반응에 미치는 영향)

  • ;Deb
    • KSBB Journal
    • /
    • v.8 no.5
    • /
    • pp.417-423
    • /
    • 1993
  • The effect of moisture content of biocatalyst on the performance of a gas phase continuous bioreactor was investigated along with study on the mass transfer limitation. The biocatalysts whose moisture contents are 46.2% and 37.2%, respectively were prepared by immobilization of alcohol oxidase on Amberlite IRA-400, following by slow dehydration method, and packed into a column. Relative production rate (RPR), acetaldehyde composition ($X_p$) and conversion (X) of biocatalysts (37.2%) are better than those of biocatalysls (46.2%), and it was considered that these are attributed to the mass transfer enhancement in the gas phase compared with the aqueous phase.

  • PDF

Characteristics of the (Ba1-xPbx)TiO3 Powders Prepared by Various Synthesis Method (제조 방법에 따른 (Ba1-xPbx)TiO3 분말특성)

  • 조경화;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.1
    • /
    • pp.127-135
    • /
    • 1990
  • Characteristics of the sol-gel derived (Ba1-xPbx)TiO3 powders are compared with those of powders prepared by the calcining ofmixed oxides method (CMO) and molten salt synthesis method(MSS). The sol-gel derived powder has a higher surface area (50$m^2$/g) than those of CMO(3.8$m^2$/g) and MSS(11.5$m^2$/g) derived powders. In the sol-gel method, the (Ba1-xPbx)TiO3 was synthesized at $600^{\circ}C$ for 1hr, indicating that this method has a crystalline temperature 20$0^{\circ}C$-30$0^{\circ}C$ lowr than those of the CMO and MSS methods.

  • PDF

Design of an X-band patch array antenna for an energy saving system (절전센서용 X-밴드 대역 패치 어레이 안테나 설계)

  • Chae, Gyoo-Soo;Lim, Joong-Soo;Kim, Min-Nyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.130-133
    • /
    • 2010
  • 본 논문에서는 X-band 절전센서용 마이크로스트립 구형패치 배열 안테나의 설계 방법을 제안 하고자 한다. 제안된 배열 안테나는 송 수신 안테나가 각각 1x2배열로 구성 되었다. 안테나는 CST MWS를 사용하여 시뮬레이션 하였고 FR-4 기판(h=1.0mm, ${\varepsilon}_r$=4.4)을 사용하여 제작하였다. 시뮬레이션 결과는 대역폭이 4%(VSWR${\leq}$2), 이득은 6.3dBi, 빔폭은 약 $60^{\circ}$(El)/$15^{\circ}$(Az)로 예측되었다. 안테나는 시뮬레이션 결과를 바탕으로 제작 되었고 절전센서용 RF 송수신기 회로 뒷면에 설치되어 무반사실에서 방사 특성을 측정하였다. 측정된 결과는 대역폭이 7%(VSWR${\leq}$2), 이득은 4.8dBi, 빔폭은 약 $55^{\circ}$(El)/$15^{\circ}$(Az)로 시뮬레이션 결과와 매우 유사한 결과를 얻었다.

  • PDF

A Study on the Dropping Shock of Household Electric Appliances during Materials Handling (가전제품의 하역 중 낙하충격에 관한 연구)

  • Lee, Soo-Keun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.6 no.1
    • /
    • pp.37-40
    • /
    • 2000
  • This study was carried out to investigate dropping shock of household electric appliances during materials handling. Microwave oven($18{\ell}$), TV(16") and washing machine(6.2kg) were singled out as the study items. From the results of dropping test by KS A 1026(General Rules of Performance Testing for Packaged Freights), relative equations were gained as follow : y=0.0863x+10.032 for microwave oven, y=0.136x+7.85 for TV and y=0.214x+5.8 for washing machine (where y is G-factor and x is Dropping height). The maximum values of dropping shock during materials handling were measured to be $11{\sim}14G$ for microwave oven, $12{\sim}15G$ for TV and $10{\sim}12G$ for washing machine. The maximum shocks of microwave oven, TV and washing machine during materials handling were corresponding to dropping shocks of dropping height 45.98cm, 52.57cm and 28.97cm by KS A 1026.

  • PDF

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

The Error-Resilient Transmission of MPEG-4 Patient Video using UDP Over CDMA2000 1xEV-DO Network (CDMA2000 1xEV-DO망에서 UDP를 사용한 MPEG-4 환자 영상의 에러에 강인한 전송)

  • Lee Tong-Heon;Yoo Sun-Kook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.510-516
    • /
    • 2005
  • Rapid advances in telecommunication make emergency telemedicine possible that specialist offers medical care to an emergency case in moving vehicle. Although there were many telemedicine projects delivering the image or video of patient over several wireless networks, none of them considered effective solutions for optimizing video transmission over error-prone environments, such like wireless links. To alleviate the effect of channel errors on compressed video bit-stream, this paper analyzed the error resilient features of MPEG-4 standard and measured the quality of transmitted MPEG-4 encoded video over commercially available CDMA2000 1xEV-DO networks, transmitting different IP packet sizes and RM positions. we propose an error resilient transmission methods for emergency telemedicine over real 3G network.

Estimation of Change Point in Process State on CUSUM ($\bar{x}$, s) Control Chart

  • Takemoto, Yasuhiko;Arizono, Ikuo
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.3
    • /
    • pp.139-147
    • /
    • 2009
  • Control charts are used to distinguish between chance and assignable causes in the variability of quality characteristics. When a control chart signals that an assignable cause is present, process engineers must initiate a search for the assignable cause of the process disturbance. Identifying the time of a process change could lead to simplifying the search for the assignable cause and less process down time, as well as help to reduce the probability of incorrectly identifying the assignable cause. The change point estimation by likelihood theory and the built-in change point estimation in a control chart have been discussed until now. In this article, we discuss two kinds of process change point estimation when the CUSUM ($\bar{x}$, s) control chart for monitoring process mean and variance simultaneously is operated. Throughout some numerical experiments about the performance of the change point estimation, the change point estimation techniques in the CUSUM ($\bar{x}$, s) control chart are considered.

Sr modified $PbTiO_3$ thin films for tunable microwave device application (MOD법에 의한 Sr modified $PbTiO_3$ 박막 제조 및 Tunable microwave device 응용 특성 연구)

  • Kang, D.H.;Cho, S.C.;Cha, H.J.;Cho, B.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.749-751
    • /
    • 2002
  • $(Pb_{1-x}Sr_x)TiO_3$ $(0.6{\leq}x{\leq}0.8)$ thin films were prepared by the MOD method for tunable microwave device application and their characteristics were investigated as a function of Sr content(x) and applied field. Thin films showed a homogeneous microstructure and the tetragonality(c/a) was slightly decreased with increasing Sr content. With increasing Sr content, Curie temperature of the thin films showed a decreasing tendency. For the PST thin films, the dielectric constant at room temperature, Tc, and $tan{\delta}$ were 750~1900, $-70^{\circ}{\sim}-30^{\circ}C$ and 0.025~0.04, respectively.

  • PDF

Microwave Dielectric Properties of xZnO+{1-x)$TiO_2$ Ceramic Systems (xZnO+(1-x)$TiO_2$계 세라믹의 마이크로파 유전특성)

  • Sim, Woo-Sung;Bang, Jae-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.605-608
    • /
    • 2002
  • In order to improve the microwave dielectric properties of ZnO+$TiO_2$ ceramic systems, we studied the relations among microstructures, phases, and microwave dielectric properties at various mole ratio and sintering temperatures. The optimum composition was found to be 0.2ZnO+0.8$TiO_2$ when sintered at $1100^{\circ}C$, at which we could obtain following results: $Q{\times}f_o$ = 22,500 GHz, ${\varepsilon}_r$ = 73, and $\tau_f=+210ppm/^{\circ}C$.

  • PDF

X-ray and gamma ray shielding behavior of concrete blocks

  • Hernandez-Murillo, Christian Geovanni;Contreras, J. Rafael Molina;Escalera-Velasco, Luis Alberto;de Leon-Martineza, Hector Asael;Rodriguez-Rodriguez, Jose Antonio;Vega-Carrillo, Hector Rene
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1792-1797
    • /
    • 2020
  • The shielding characteristics of two concrete blocks, widely used in the building industry in Mexico have been determined. These characteristics include the mass interaction coefficients, the linear attenuation coefficients and the half-value layers. The energy-dispersed X-ray fluorescence shows that the percentage mass content of each atom in the sample, and the atomic volume of the constituent elements of a material, plays an important role in its shielding capabilities. The total linear attenuation coefficients and the half-value layers were analyzed for a set of photon energies related to X-rays for diagnosis and cancer treatment with linear accelerators. Our results show that the concrete blocks have similar photon attenuation coefficients than the Portland concrete and better features than gypsum.