• Title/Summary/Keyword: X-ray method

Search Result 4,392, Processing Time 0.032 seconds

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

A Study on the Optimal X-ray Angle to Observe Calcaneus (발꿈치뼈를 관찰하기 위한 최적의 X-ray 각도에 대한 고찰)

  • Sang-Min Shin;Bo-Moon Seo;Hae-In Jeon;Gyoung-Han Lee;Min-Cheol Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, using an X-ray device (Drgem TS-CSP) and foot phantom (SFT-1556), the angle of the X-ray tube was changed to 30°, 35°, 40°, 45°, and 50°, and the image was evaluated by quantitative and qualitative evaluation. In the blind test, it was the highest at 4.34 points at 40°, and in the part calculation using the Image J program, the angle was the largest at 1750 at 50°. In addition, in the area evaluation excluding overlapping areas, the X-ray tube showed the largest value at 40° Therefore, it was found that the X-ray tube angle was suitable when the X-ray tube angle was 40° as a projection method for observing the calcaneus.

Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection (X-선 투과검사를 이용한 저항 점용접부 품질평가기법)

  • Lee, Jong-Dae;Lee, So-Jeong;Bang, Jung-Hwan;Yoon, Gil-Sang;Kim, Mok-Soon;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

A Study of Practical and Optimized Mineral Quantification (실용적이고 최적화된 광물정량분석법 연구)

  • Son, Byeong-Kook;An, Gi-O
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.227-239
    • /
    • 2021
  • A practical and effective method of X-ray powder diffraction analysis was investigated for quantitative analysis of the mineral content of natural samples. Sample mounting experiments were conducted to select the best randomly oriented powder sample mount. A comparative experiment was also made between a reference intensity ratio (RIR) method, which compares a single peak intensity with standard material, and the Rietveld method, which calculates a full X-ray diffraction pattern, to search for the effective method of mineral quantification. In addition, samples containing amorphous minerals were quantitatively analyzed by the Rietveld method and the efficiency was reviewed. As a result of the study, the optimal random orientation could be reached by the side mounting method. The Rietveld method using the full pattern of X-ray diffraction was more suitable for mineral quantitative analysis, rather than the RIR method using a specific peak. However, either method could depend on the analyst's experience in addition to analytical technique. Moreover, amorphous minerals can be quantitatively analyzed by the Rietveld method, and the analysis results make the geological analysis possible.

The ConvexHull using Outline Extration Algorithm in Gray Scale Image (이진 영상에서 ConvexHull을 이용한 윤곽선 추출 알고리즘)

  • Cho, Young-bok;Kim, U-ju;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.162-165
    • /
    • 2017
  • The proposed paper extracts the region of interest from the x-lay input image and compares it with the reference image. The x-ray image has the same shape, but the size, direction and position of the object are photographed differently. In this way, we measure the erection difference of darkness and darkness using the similarity measurement method for the same object. Distance measurement also calculates the distance between two points with vector coordinates (x, y, z) of x-lay data. Experimental results show that the proposed method improves the accuracy of ROI extraction and the reference image matching time is more efficient than the conventional method.

  • PDF

Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems (캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구)

  • Yoon, Yeon Ah;Jung, Jin Hyeong;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.

3D Coordinates Acquisition by using Multi-view X-ray Images (다시점 X선 영상을 이용한 3차원 좌표 획득)

  • Yi, Sooyeong;Rhi, Jaeyoung;Kim, Soonchul;Lee, Jeonggyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

High pressure X-ray diffraction study on a graphite using Synchrotron Radiation (고압하에서 방사광을 이용한 흑연에 대한 연구)

  • Kim, Young-Ho;Na, Ki-Chang
    • The Journal of the Petrological Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1994
  • High pressure X-ray diffraction study was carried out on a graphite to investigate its compressibility as well as any possible phase transition to the hexagonal diamond structure at room temperature. Energy dispersive X-ray diffraction method was introduced using a Mao-Bell type diamond anvil cell with Synchrotron Radiation. Polycrystalline sodium chloride was compressed together with graphite for the high pressure determinations. Because of the poor resolution of the X-ray diffraction pattern of graphite, its compressibility was estimated to be almost same as that of NaCl by graphite (002) X-ray diffraction peak only. An observation of any new peak from a possible hexagonal diamond phase seems very unplausible for its definite identification based on the present data. Alternative approaches such as an Wiggler Radiation source as well as a Large Volume high pressure apparatus will be necessary for the detailed studies on a graphite in future.

  • PDF

A study on thermal fluid analysis in X-ray tube for non-fire alarm (비화재보를 위한 X-ray tube 내 열 유동해석에 관한 연구)

  • Yun, Dong-Min;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.33-38
    • /
    • 2022
  • Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.

Comparison of Output and Radiation Quality of X-rays according to the Full-Wave Rectification Method and Dual-Voltage Rectification Method of an X-ray Generator (X선 고전압장치의 전파 및 배전압 정류방식에 따른 X선 출력 및 선질 비교)

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.534-538
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. Being capable of locally inspecting the inside of the body, X-ray systems are routinely used for basic diagnosis. X-ray systems to be used for medical purposes were originally made with a gas filled tube inside an induction coil in the initial stages of development but with this approach it becomes difficult to take a satisfactory picture through thick body sections, non invasively. However continued development made it possible to take non-invasive pictures of breasts, blood vessels and other body parts through thick body sections. Recently, high-voltage X-ray generators of more compact size, increased generation efficiency, and sophisticated output control have become possible. All of these features are made possible by the use of a high-frequency output from an inverter and a fast switching semiconductor device. In this paper, we describe a new X-ray generator operating with a resonant inverter in order to reduce switching loss and high frequency noise. In addition, in order to identify the differences amongst types of rectification, we have compared output and the quality of X-ray pictures obtained with full-wave rectification and dual-voltage rectification methods.