• 제목/요약/키워드: X-ray method

검색결과 4,385건 처리시간 0.03초

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • 한국멀티미디어학회논문지
    • /
    • 제25권10호
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.

TFT-DXD 방식의 디지털 X-ray Detector를 이용한 고효율 의료 영상처리시스템 (An Effective Medical Image System using TFT-DXD Method's Digital X-ray Detector)

  • 황재석;이재균;이채욱
    • 한국통신학회논문지
    • /
    • 제32권4C호
    • /
    • pp.389-395
    • /
    • 2007
  • 기존의 필름 X-Ray 및 CCD(Charge Coupled Device) 방식은 공간적인 제약과 진단 시간이 많이 걸리는 단점이 있다. 본 논문에서는 기존 방식들의 단점을 보완할 수 있는 TFT-DXD 방식의 digital X-ray detector (DR1000C)를 이용한 고효율 의료 영상처리시스템을 구현하였다. 본 논문에서 제안하는 DR1000C를 이용한 의료용 영상처리시스템은 기존의 X-Ray 방식에 비해 공간 효율성이 높고 진단 시간이 짧아진다는 장점이 있다. 영상처리시스템에서 획득한 영상을 고화질로 만들기 위해 1900*1200의 해상도를 가지는 LCD 컨트롤 드라이버를 개발하였고, 영상의 성능향상을 위해 enhancement unsharp masking 기법을 제안하여, 기존의 방식과 비교하였다.

X-선 튜브의 고전압 발생장치 제어에 관한 연구 (Study on Generator Control for a Small X-Ray Tube)

  • 이순혁;지윤서;최상규;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.248-254
    • /
    • 2014
  • 본 연구에서는 미국 Xoft 사에서 근접치료 장치(elecronic brachytherapy)를 목적으로 개발된 소형 X-선 튜브를 치과용 영상장비로 사용함에 있어서 고전압 발생장치의 제어용 장치를 개발하고 영상용 제어 방식으로 최적화하고자 한다. 연구에서 사용된 X-선 튜브와 고전압 발생 장치는 각각 Axxent S700과 XF060NZZ485를 사용하였고, AT90CAN128 MCU를 사용하여 제어보드를 제작하였다. 관전압을 50 kV로 고정한 후에 제어 방식에 따라서 필라멘트 전류 제어 방식과 관전류제어 방식으로 나누었다. 필라멘트 제어 방식은 다시 필라멘트 가열 시간에 따라서 5초와 10초의 두 가지로 나누어 실험하였다. 필라멘트 전류 제어 방식에서는 필라멘트 예열 시간이 10초 이상이 되지 않으면 설정된 관전류 값에 도달하기 어려웠고, 관전류가 발생하는 필라멘트 전류도 1,300~1,350 mA로 가변적이었으며, 관전류가 발생된 이후에도 설정된 목표 값에 도달하기 위해서는 약 5초 이상의 시간이 소요되었다. 하지만 관전류 제어 방식에서는 관전류가 설정된 목표 값에 시간 지연 없이 즉각적으로 도달하였으며 그 때의 필라멘트 전류 값은 1,500 mA였다. 본 연구에서는 소형의 X-선 튜브에 고전압을 안정적으로 공급하는 제어 장치를 개발하였고, 방사선 영상장비로 사용함에 있어서는 관전류 제어 방식이 적합함을 보였다.

6 DOF Pose Estimation of Polyhedral Objects Based on Geometric Features in X-ray Images

  • Kim, Jae-Wan;Roh, Young-Jun;Cho, Hyung-S.;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.63.4-63
    • /
    • 2001
  • An x-ray vision can be a unique method to monitor and analyze the motion of mechanical parts in real time which are invisible from outside. Our problem is to identify the pose, i.e. the position and orientation of an object from x-ray projection images. It is assumed here that the x-ray imaging conditions that include the relative coordinates of the x-ray source and the image plane are predetermined and the object geometry is known. In this situation, an x-ray image of an object at a given pose can be estimated computationally by using a priori known x-ray projection image model. It is based on the assumption that a pose of an object can be determined uniquely to a given x-ray projection image. Thus, once we have the numerical model of x-ray imaging process, x-ray image of the known object at any pose could be estimated ...

  • PDF

THE X-RAY EMISSION FROM EARLY TYPE GALAXIES

  • Kim, Dong-Woo
    • 천문학논총
    • /
    • 제7권1호
    • /
    • pp.63-69
    • /
    • 1992
  • We have systematically investigated the X-ray spectra of normal galaxies, by using the Imaging Proportional Counter (IPC) data in the Einstein data base. We employed the X-ray color-color plot as well as the standard model fitting method which requires higher signal to noise ratio. We discuss X-ray emission mechanisms in terms of their spectral properties and the signature of cooling flows which are most likely present in X-ray bright early type galaxies. On the average, fits to absorbed thermal spectra show that the X-ray emission temperature of spirals is higher than that of ellipticals. This is consistent with our understanding that accreting binaries are a major X-ray source in spirals, while extended gaseous halos are present in ellipticals. The emission temperature becomes lower with increasing X-ray to optical luminosity ratio in E and S0 galaxies. This result is what we would expect if the emission of X-ray faint early type galaxies consists of a large evolved stellar component, while the gaseous emission becomes dominant in X-ray brighter galaxies. We also find a cool, self-absorbed core in some early type galaxies, which directly indicates the presence of cooling flows in such galaxies.

  • PDF

혼합형 CdZnTe 검출기의 X선 반응특성 (X-ray Response Characteristic of Hybrid-type CdZnTe Detector)

  • 차병열;강상식;공현기;이규홍;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.35-38
    • /
    • 2002
  • In this paper, for digital x-ray conversion receptor development studied by hybrid technology of based on CdZnTe. For this study, First searched fabricate method of CdZnTe x-ray receptor. Second, search the phosphor material & fabricate method for scintillator layer. Fabricated sample is analyzed with physical & electric measurement. This result is showed good SNR ratio hybrid thechnology with direct method & indirect method. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

금속재료 표면층의 급격한 응력구배에 대한 X-Ray회절 특성값과 측정된 변형률의 해석방법 (Analysis Method of X-Ray Diffraction Characteristic Values and Measured Strain for Steep Stress Gradient of Metal Material Surface Layer)

  • 한창석;이찬우
    • 한국재료학회지
    • /
    • 제33권2호
    • /
    • pp.54-62
    • /
    • 2023
  • The most comprehensive and particularly reliable method for non-destructively measuring the residual stress of the surface layer of metals is the sin2ψ method. When X-rays were used the relationship of εφψ-sin2ψ measured on the surface layer of the processing metal did not show linearity when the sin2ψ method was used. In this case, since the effective penetration depth changes according to the changing direction of the incident X-ray, σφ becomes a sin2ψ function. Since σφ cannot be used as a constant, the relationship in εφψ-sin2ψ cannot be linear. Therefore, in this paper, the orthogonal function method according to Warren's diffraction theory and the basic profile of normal distribution were synthesized, and the X-ray diffraction profile was calculated and reviewed when there was a linear strain (stress) gradient on the surface. When there is a strain gradient, the X-ray diffraction profile becomes asymmetric, and as a result, the peak position, the position of half-maximum, and the centroid position show different values. The difference between the peak position and the centroid position appeared more clearly as the strain (stress) gradient became larger, and the basic profile width was smaller. The weighted average strain enables stress analysis when there is a strain (stress) gradient, based on the strain value corresponding to the centroid position of the diffracted X-rays. At the 1/5 Imax max height of X-ray diffraction, the position where the diffracted X-ray is divided into two by drawing a straight line parallel to the background, corresponds approximately to the centroid position.

앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구 (A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.189-193
    • /
    • 2011
  • 상지 검사(upper extremity X-ray examinations, UEX) 시 환자 위치 잡이로 가장 많이 활용되고 있는 앉은 자세 상지 X-ray 검사(sitting position upper extremity X-ray examinations, SUEX) 시 방사선에 민감한 생식샘과 목적장기 이외 부위에 대한 피폭이 크다고 판단되어 의료기관 별 SUEX 시 납 앞치마(Apron) 착용 유무와 생식샘 및 목적장기 이외 부위에 대한 방사선 피폭과 피폭선량 감소 방안에 대한 연구 결과 거리가 멀어 질수록, 조사야 조절장치를 가능한 목적장기 부위로 제한 조절할수록, 피사체의 두께가 얇을수록 방사선에 의한 피폭은 감소하였고, 생식샘 차폐 유무에 따른 피폭은 생식샘을 차폐했을 때 약 10~50%의 저감화효과를 얻을 수 있었다. 또한 검사 시 apron 착용 유무에 대한 조사에서는 대부분의 경우 apron을 착용하지 않은 것으로 조사되어 시급히 시정되어야 될 것으로 생각된다.

Sparse 표현을 이용한 X선 흡수 영상 개선 (X-ray Absorptiometry Image Enhancement using Sparse Representation)

  • 김형일;엄원용;노용만
    • 한국멀티미디어학회논문지
    • /
    • 제15권10호
    • /
    • pp.1205-1211
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현을 도입하여 다중(multiple) 잡음을 갖는 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink 잡음 제거 방법 및 일반적 sparse 표현 모델의 잡음 제거 방법의 결과에 비해 개선됨을 CNR(Contrast to Noise Ratio) 및 cut-view를 통해 확인하였다.