• 제목/요약/키워드: X-ray method

검색결과 4,385건 처리시간 0.04초

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

디지털 x-ray 영상시스템을 위한 무선 트리거 발생기 (Wireless Triggering Pulse Generation for Digital X-ray Imaging System)

  • 고대식;이재철;이주신
    • 한국항행학회논문지
    • /
    • 제11권2호
    • /
    • pp.163-169
    • /
    • 2007
  • 본 논문에서는 x-ray 영상시스템의 영상을 획득하기 위하여 x-ray 발생기와 영상획득시스템 사이의 동기를 맞추어 주는 트리거 발생기를 연구분석 하였다. 무선 트리거 발생기는 디지털영상 획득시스템으로부터 영상획득의 시작을 지시할 수 있는 ACQ_START 신호와 영상획득의 끝을 알리는 ACC_END 신호를 발생시킬 수 있도록 설계하였다. 디지털 영상의 획득은 ACQ_START 신호와 ACQ_END 신호 사이의 시간동안에만 정확하게 이루어지며 무선 원격 x-ray 신호의 검출을 통하여 유선통신 프로토콜 없이 정확한 x-ray 영상의 획득이 가능하고 20 mAs 의 x-ray 레벨에서 3.5 line pair /mm 분해능을 나타냄을 확인하였다.

  • PDF

X-ray PIV Measurements of Velocity Field of Blood Flows

  • 이상준
    • 순환기질환의공학회:학술대회논문집
    • /
    • 순환기질환의공학회 2006년도 춘계학술강연회
    • /
    • pp.28-36
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구 (Study of Discharge Erasing Method of a-Se based Digital X-ray Detector)

  • 이동길;박지군;최장용;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

Analysis of X-ray image qualities-accuracy of shape and clearness of image-using X-ray digital tomosynthesis

  • Roh, Young Jun;Kang, Sung Taek;Kim, Hyung Cheol;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.572-576
    • /
    • 1997
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promise to be good solutions for inspecting interior defects of industrial products. The major factors of the digital tomosynthesis that influence on the quality of x-ray cross-sectional images are also discussed. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria: (1) shape accuracy and (2) clearness in the cross-sectional image are defined. Based on this criteria, a series of simulations were performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum method.

  • PDF

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • 제13권3호
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정 (Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가 (Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate)

  • 김상후;김형준;한은옥;한승무
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.551-556
    • /
    • 2004
  • 본 연구에서는 진단 방법의 정확성이 아직까지 구체적으로 규명되지 않고 있는 어린이의 성장 발육을 체계적이고 과학적으로 측정할 수 있는 방법을 제시하고자 시도하였다. 현재 많이 이용되고 있는 성장 진단 방법은 X-ray 영상을 이용한 각 관절 부위의 성장판의 개폐 분석이다. 그러나 X-ray 방식은 성장 진단에서 요구되는 주기적이고 반복적인 측정을 하지 못함과 동시에 방사선 노출이라는 단점을 가지고 있다. 따라서 인체에 무해한 초음파 영상을 이용한 성장판 개폐 분석 대체 가능성을 평가하기 위해 종골의 초음파 광역 감쇄 영상을 이용한 프로파일 분석 및 성장판 영상 분석 알고리즘을 제시하였다. 본 연구에서는 7세~16세의 어린이 269명에 대해서 X-ray를 이용하여 무릎, 손가락, 종골에서의 성장판 영상을 얻었다. 또한 초음파 방식을 이용하여 종골의 성장판 영상을 얻었다. 각 관절에서의 성장판 개폐 유무 시기는 각 개인별로 측정 방법에 따라 조금의 차이는 있으나 전반적으로 일치하였다. 또한. X-ray방식과 초음파 방식에 의한 성장판 영상을 비교한 결과 상호 높은 연관성을 나타내었다. 이와 같이 성장판을 정확하게 측정하기 위해 도입된 초음파 프로파일 분석 알고리즘은 기존의 X-ray 영상 방식에 의한 성장판의 측정을 대체할 수 있을 것으로 사료된다.