• 제목/요약/키워드: X-ray laser

검색결과 481건 처리시간 0.027초

LASER-PRODUED PLASMA AS AN X-RAY SOURCE

  • 김효근
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.64-64
    • /
    • 1991
  • The interaction of high-intensity, focused, nanosecond laser light with matter results in the production of high-temperature plasma, which in turn emits an intense pulse of x rays. The x-ray spectrum consists of strong line components of several keV photon energy and broad continuum. Such an x-ray source provides many advantages over conventional ones for many applications. Pulse nature of the x-ray emission is well-suited for studying transient phenomena and for imaging living biological specimen. Recent experiments have also shown that the laser plasma x ray may be used for x ray lithography. These studies and other applications will be discussed in detail.

  • PDF

Efficient keV X-ray Generation from Irradiation of in-situ Produced Silver Clusters by Ti:sapphire Laser Pulses

  • Chakravarty, U.;Naik, P.A.;Kumbhare, S.R.;Gupta, P.D.
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.80-85
    • /
    • 2009
  • An experimental study of energy absorption and x-ray emission from ultrashort laser pulse irradiation of in-situ produced solid clusters has been performed. Silver clusters produced by a 30 mJ, 300 ps laser pulse were irradiated up to an intensity of $3{\times}10^{17}\;W/cm^2$ by a 70 mJ, 45 fs compressed laser pulse from the same Ti:sapphire laser. Absorption of the laser light exceeding 70% was observed, resulting in an x-ray yield (>1 keV) of ${\sim}60{\mu}J$ pulse. This may constitute a much simpler means of intense x-ray generation using ultrashort laser pulses as compared to the irradiation of structured / pre-deposited cluster targets, and it offers higher x-ray conversion efficiency than that from gas clusters and planar solid targets.

Conceptual Design of Soft X-ray Microscopy for Live Biological Samples

  • Kim, Kyong-Woo;Nam, Ki-Yong;Kwon, Young-Man;Shim, Seong-Taek;Kim, Kyu-Gyeom;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제7권4호
    • /
    • pp.230-233
    • /
    • 2003
  • This study describes the conceptual design of a soft x-ray microscope system based on a laserbased source for biomedical application with high resolution (${\leq}$50nm). The laboratory scale soft x-ray microscope consists of high power laser plasma x-ray source and grazing incidence mirrors with high reflectivity. The laser plasma source used for developing this system employs Q-switched Nd-YAG pulsed laser. The laser beam is focused on a tantalum (Ta) target. The Wolter type I mirror was used as condenser optics for sample illumination and as objective mirror for focusing on a detector. The fabrication of the Wolter type I mirror was direct internal cutting using ultraprecision DTM. A hydrated biological specimen was put between the two silicon wafers, the center of which was $Si_3N_4$ windows of 100㎚ thickness. The main issues in the future development work are to make a stable, reliable and reproducible x-ray microscope system.

레이저-플라즈마를 이용한 X-선 레이저의 연구 (X-ray laser development using laser-produced plasmas)

  • 남창희
    • 한국광학회지
    • /
    • 제3권1호
    • /
    • pp.67-72
    • /
    • 1992
  • 7년전 두 개의 그룹에 의해 강한 증폭된 자발 방출이 200.angs. 영역에서 관찰된 이래, 증폭도의 증가와 작동 파장영역의 확장등에서 세계적으로 많은 X-선 레이저 연구가 이루어져 왔다. X-선 레이저의 개발은 살아있는 생체조직을 고분해능으로 관찰할 수 있는 X-선 현미경 기술, 세포의 3차원 상을 가능케 하는 X-선 홀로그래피 기술, 고밀도 플라즈마의 진단 등의 여러 분야에 응용될 것이다. 국내에서도 기초적인 X-선 레이저 개발에 대한 연구가 과학기술원과 포항공과대학에서 시작되고 있어 곧 고무적인 연구결과가 나올 것으로 기대된다.

  • PDF

A Monochromatic Soft X-ray Generation from Femtosecond Laser-produced Plasma with Aluminum

  • Son, Joon-Gon;Hwang, Byung-Jun;Seo, Okkyun;Kim, Jae Myung;Noh, Do Young;Ko, Do-Kyeong
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1834-1839
    • /
    • 2018
  • A tabletop ultrafast soft x-ray has been generated from the laser-produce plasma with a femtosecond pulsed Ti:Sapphire laser. The estimated total flux of Al $K{\alpha}$ is of $2.2{\times}10^9photons/sec$ in $4{\pi}$ radian and the parameters related to the optical performance were obtained. The tungsten/silicon multilayer, flat quartz and bent thallium acid phthalate (TLAP) crystal were used for monochromatization of soft x-ray to refine the aluminum $K{\alpha}$ radiation and compared the respective value of $E/{\Delta}E$. To estimate the size of the x-ray source beam generated by a fs laser, the approximation using the FWHM obtained from the x-ray beam scan near the focal point was discussed, and the size of the diameter was about $9.76{\mu}m$.

High-resolution Spectroscopy of the Nickel-like Molybdenum X-ray Laser Toward the Generation of Circularly Polarized X-ray Laser

  • Hasegawa, Noboru;Sasaki, Akira;Yamatani, Hiroshi;Kishimoto, Maki;Tanaka, Momoko;Ochi, Yoshihiro;Nishikino, Masaharu;Kunieda, Yuichi;Kawachi, Tetsuya;Yoneda, Hitoki;Iwamae, Atsushi
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.60-64
    • /
    • 2009
  • We attempted the first measurement of the spectral width of the nickel-like molybdenum x-ray laser (${\lambda}\;=\;18.895\;nm$) by use of a high-resolution spectrometer in order to determine the strength of the magnetic field required for the generation of a circularly polarized x-ray laser. The spectral width was measured to be ${\Delta}{\lambda}\;=\;18\;m{\AA}$ under the substantial lasing condition. The magnetic field required for the generation of a circularly polarized x-ray laser was 40 T. The splitting of the x-ray laser line was clearly obtained under 15 T external magnetic field. The strength of the magnetic field estimated from the splitting of the x-ray laser line was large compared with the external magnetic field. It implies that there might be an alternative mechanism for enhancement of the magnetic field in the gain medium plasma.

다이오드 레이저를 이용한 금속 표면 열처리 특성 (Characteristics of Metal Surface Heat Treatment by Diode Laser)

  • 최성대;정선환;김기만;양승철;김잠규
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.16-23
    • /
    • 2007
  • An experimental investigation with diode laser system was carried out to study the effect of surface heat treatment on the die materials(SM45C, SKD11, SK3). The surface heat treatment characteristics of the laser beam are evaluated using hardness tests, optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy(EDS). Results indicated that the beam size, focal length, feed rates are changed surface hardened characteristics. SM45C is higher hardness than other materials and composed to martensite grain at hardened zone, whereas other materials(SKD11, SK3)are low hardness than expected and composed to austenite and allayed martensite at hardened zone. The intensive X-ray diffraction patterns of (110)-(200)-(211) is detected hardened surface and the hardened surface distributed plenty of carbon density than metal zone.

  • PDF

X-선 자유전자 레이저를 위한 새로운 과학 (New Science Opportunities with X-Ray Free Electron Laser)

  • 구태영
    • 한국자기학회지
    • /
    • 제21권6호
    • /
    • pp.231-236
    • /
    • 2011
  • X-선 자유전자레이저(XFEL)는 펨토초의 펄스형태, 완벽한 결맞음 및 고휘도 특성으로 X-선 실험과학분야의 새로운 시대를 예고하는 꿈의 X-선 광원장치로 언급되고있다. XFEL에 관한 간략한 소개와 현재 세계적으로 진행되고 있는 XFEL 시설현황을 살펴보고, 대표적인 실험장치를 개념적으로 분류해서 정리해 보고자 한다. 특히 자성연구분야와 관련된 제안 및 연구사례를 간략하게 언급하고, 지금 현재 진행 중인 포항가속기연구소의 XFEL 프로젝트의 개요와 XFEL 활용을 위해서 제안된 대표적인 과학프로그램을 살펴보고자 한다.

레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계 (Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application)

  • 김경우;윤권하
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

집속된 광분해 옥소레이저에 의한 플라즈마로부터 방출되는 연속 X-선 스펙트럼 분석과 전자온도 결정 (Analysis of Continuum X-ray Specturum and Determination of Electron Temperature from Iodine Photodissociation Laser produced plasma)

  • 김동환;김남성;이상수
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1988년도 광학 및 양자전자학 워크샵
    • /
    • pp.135-144
    • /
    • 1988
  • 1-GW Iodine photodissociation Laser (λ=1.315${\mu}{\textrm}{m}$)is focused to generate the continuum x-ray radiation at titanium(z=22)target. A piced of aluminum(360 )-mylar(8${\mu}{\textrm}{m}$) film is used to isolate the soft X-ray radiation emitted. Convex-xurved mica crystal spectrometer is used to obtain the soft x-ray spectra from the laser titanium target plasma and the slope of continum X-ray spectra are found to show two different different electron effective temperaturres, 0.11keV and 7.1KeV. We compare the two temperature result with the foil absorption method.

  • PDF