• 제목/요약/키워드: X-ray image

검색결과 1,285건 처리시간 0.027초

X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정 (Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

CCD 카메라를 사용한 저가형 Digital X-Ray 영상취득 시스템 (Low Cost Digital X-Ray Image Capture System Using CCD Camera)

  • 강용철
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.19-22
    • /
    • 2007
  • We developed a low cost digital X-Ray image capturing system using a CCD camera, instead of using the high cost image plate and image intensifier. In order to reduce the system volume, we directly made the dark box shorter than the previous model. Using the graphic language, we developed a program in order for post-processing the images captured by the CCD camera. This program improves the image resolving power.

An X-ray Image Panorama System Using Robust Feature Matching and Per ception-Based Image Enhancement

  • Wang, Weiwei;Gwun, Oubong
    • 한국멀티미디어학회논문지
    • /
    • 제15권5호
    • /
    • pp.569-576
    • /
    • 2012
  • This paper presents an x-ray medical image panorama system which can overcome the smallness of the images that exist on a source computer during remote medical processing. In the system, after the standard medical image format DICOM is converted to the PC standard image format, a MSR algorithm is used to enhance X-ray images of low quality. Then SURF and Multi-band blending are applied to generate a panoramic image. Also, this paper evaluates the proposed SURF based system through the average gray value error and image quality criterion with X-ray image data by comparing with a SIFT based system. The results show that the proposed system is superior to SIFT based system in image quality.

엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구 (Image Quality Improvement through Energy Spectrum Change for X-ray)

  • 김구;김능균;이승재
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 엑스선 영상을 획득하는 경우에 연속 엑스선을 사용할 경우, 다양한 엑스선 에너지로 인해 같은 물질이라도 두께에 따라 영상에서 정확하게 표현되지 않을 수 있다. 이를 해결하기 위해 엑스선 에너지스펙트럼을 변경하여 영상의 질을 향상 시킬 수 있도록 하였다. SPEKTR v3.0을 사용하여 부가 필터를 추가한 엑스선 에너지스펙트럼과 고유 필터만을 사용한 일반 엑스선 에너지스펙트럼을 획득하였다. 획득한 엑스선 에너지스펙트럼을 Geant4 Application for Tomographic Emission(GATE)의 방사선원으로 사용하여 시뮬레이션을 수행하였다. GATE 데이터를 사용하여 부가 필터가 사용된 엑스선 영상과 부가 필터를 사용하지 않은 엑스선 영상을 재구성한 영상을 74 keV의 단일 에너지 영상을 통해서 비교 분석하였다. 부가 필터를 사용하지 않은 엑스선 에너지스펙트럼을 사용한 경우 같은 물질이라도 두께에 따라 투과한 엑스선의 양이 물질 두께에 따라 감소되는 양과는 상이한 양상을 보인 반면, 부가 필터를 사용한 경우 두께에 따라 투과된 엑스선의 양이 물질 두께에 따라 감소되는 양과 유사한 결과가 나왔다. 즉, 감소되는 선량이 단일 에너지를 사용했을 때와 비슷한 결과가 나왔다. 부가 필터를 사용하여 엑스선 에너지스펙트럼을 변경하여 엑스선 영상을 획득할 경우 엑스선의 투과에 대한 보다 정확한 결과의 값을 획득할 수 있다. 영상의학검사에서 부가 필터의 적절한 사용이 영상의 질을 높이는데 크게 작용한다는 것을 확인하였다.

TFT-DXD 방식의 디지털 X-ray Detector를 이용한 고효율 의료 영상처리시스템 (An Effective Medical Image System using TFT-DXD Method's Digital X-ray Detector)

  • 황재석;이재균;이채욱
    • 한국통신학회논문지
    • /
    • 제32권4C호
    • /
    • pp.389-395
    • /
    • 2007
  • 기존의 필름 X-Ray 및 CCD(Charge Coupled Device) 방식은 공간적인 제약과 진단 시간이 많이 걸리는 단점이 있다. 본 논문에서는 기존 방식들의 단점을 보완할 수 있는 TFT-DXD 방식의 digital X-ray detector (DR1000C)를 이용한 고효율 의료 영상처리시스템을 구현하였다. 본 논문에서 제안하는 DR1000C를 이용한 의료용 영상처리시스템은 기존의 X-Ray 방식에 비해 공간 효율성이 높고 진단 시간이 짧아진다는 장점이 있다. 영상처리시스템에서 획득한 영상을 고화질로 만들기 위해 1900*1200의 해상도를 가지는 LCD 컨트롤 드라이버를 개발하였고, 영상의 성능향상을 위해 enhancement unsharp masking 기법을 제안하여, 기존의 방식과 비교하였다.

양면 PCB의 납땜부 검사를 위한 새로운 X선 단층영상 시스템 (A new X-ray cross-sectional image system for solder joint inspection of double-sided PCB)

  • 강성택;정재훈;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.117-120
    • /
    • 1996
  • In this paper, a new approach to acquire the cross-sentional image for automatic solder joint inspection of double-sided PCB using X-ray source is presented. We designed the apparatus with fixed X-ray source to realize the cross-sectional image by tunning object and detector synchronously. The cross-sectional images are captured at several view angle of X-ray source, the geometric image distortions caused by view angle and the shape of image intensifier are compensated. The precision variation of cross-sectional image by the change of view angle was investigated. Also we acquired the cross-sectional image to the solder joint of double-sided PCB and reconstructed the shape of solder joint.

  • PDF

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

Sparse 표현을 이용한 X선 흡수 영상 개선 (X-ray Absorptiometry Image Enhancement using Sparse Representation)

  • 김형일;엄원용;노용만
    • 한국멀티미디어학회논문지
    • /
    • 제15권10호
    • /
    • pp.1205-1211
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현을 도입하여 다중(multiple) 잡음을 갖는 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink 잡음 제거 방법 및 일반적 sparse 표현 모델의 잡음 제거 방법의 결과에 비해 개선됨을 CNR(Contrast to Noise Ratio) 및 cut-view를 통해 확인하였다.

수완부골의 X-ray 영상 및 종골의 초음파 영상에서 측정한 골연령을 통한 소아성장에 관한 임상연구 (A Clinical Study on Growth and Development of Children Based on Their Bone Age Measured by Hand's X-ray Image and Calcaneus's Ultrasonic Image)

  • 윤혜진;서정민;강미선;백정한
    • 대한한방소아과학회지
    • /
    • 제22권2호
    • /
    • pp.155-170
    • /
    • 2008
  • Objectives : The purpose of this study was to have better data and to make efficient clinical reviews about children's growth based on two methods; X-ray of hand, and ultrasound of calcaneus. Methods : The study was composed of 100 patients(50 of boys and 50 of girls) who visited in department of pediatrics, O O university oriental hospital considering growth and their development. Bone age was measured by the TW3 method's RUS score in simple X-ray image of hand and bone density through ultrasonic image of calcaneus. To predict children's estimated height, their parent's height, bone age, and present height's percentile was measured. Results and Conclusions : 1. The bone age results from X-ray image of hand and ultrasonic image of calcaneus were correlated. Younger children have older bone age from hand's X-ray than the one from calcaneus's ultrasound. Older children have older bone age from calcaneus's ultrasound than one from hand's X-ray. 2. Predicted adult height by bone age(BH) of hand's X-ray and BH of calcaneus's ultrasound were correlated, but predicted adult height by inheritance(IH) was not correlated with others. 3. Bone age and predicted adult height were correlated with age, height, weight, BMI, and especially with age and height. 4. Measuring bone age by X-ray image of hand and ultrasonic image of calcaneus was simple and effective way of estimating children's growth and development.

  • PDF

강판튜브 엑스선 영상의 영역별 영상잡음 특성분석 (Regional Image Noise Analysis for Steel-tube X-ray Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.32-34
    • /
    • 2007
  • The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.

  • PDF