• 제목/요약/키워드: X-ray equipment for computed tomography (CT)

검색결과 12건 처리시간 0.02초

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Cone beam형 전산화단층영상의 원리 (Basic principle of cone beam computed tomography)

  • 최용석;김규태;황의환
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

현장 적용이 가능한 X선 CT 시스템 개발 II- 밀도분포를 이용한 목재의 CT영상 구성 - (Development of Portable X-ray CT System II - CT Image Reconstruction of Wood using Density Distribution -)

  • 김광모;이상준;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권1호
    • /
    • pp.23-31
    • /
    • 2006
  • X선은 강한 투과성과 직진성으로 인하여 비파괴 검사법으로써 다양한 분야에서 활용되고 있다. 본 연구에서는 고건축물과 같은 목조 건축물에 사용되고 있는 구조부재의 열화를 현장에서 탐지할 수 있는 비파괴 검사법을 개발할 목적으로 X선 CT시스템의 적용가능성을 검토하였다. 먼저 이전 연구의 결과를 바탕으로 CT영상을 구성하는 체계를 확립하고, 얻어진 CT영상을 실제 부재의 단면 형태와 비교함으로써 개발된 시스템의 적용가능성을 확인하였다. 개발된 X선 CT시스템의 적용을 통해 결함의 형태와 크기, 위치뿐만 아니라 결함에서의 밀도 또한 비교적 정확하게 탐지할 수 있음이 확인되었다. 이러한 결과는 건축물에서 사용되고 있는 목재 부재에 열화가 발생하였을 경우에, 열화 발생의 원인을 파악하고 그에 따른 효과적인 대처방안을 수립하는데 있어서 유용하게 활용될 수 있을 것으로 기대된다. 그러나 현재의 시스템은 개발 초기단계로 측정에 따른 소요시간이나 측정회수, 측정 정밀도에 있어서 여러 제약을 받는다. 따라서 이러한 제약을 극복하기 위한 추가적인 연구가 요구된다.

IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징 (Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0)

  • 김현지;김정민;최인석;윤용수;서덕남;김정수;김대영;박성용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2013
  • IEC 규격은 유럽, 일본 등 해외 여러 나라에서 자국의 규격으로서 이용되고 있으며, 우리나라에서는 현재 산업표준인 KS 형태와 더불어 강제성을 갖는 식품의약품안전청 고시로서도 발행되고 있다. 전자의료기기에 관한 IEC 규격인 IEC 60601 시리즈의 공통규격(IEC 60601-1:2005)이 3판으로 개정됨에 따라, 보조규격과 개별규격 또한 그에 맞추어 제 개정이 필요하다. IEC 규격의 변화 동향을 파악하는 것은 국내 의료기기 제조 수입업체 및 시험검사기관에서 매우 중요하다. 따라서 본 연구에서는, 진단용X선기기와 관련한 3개 규격 IEC 60601-2-44(CT의 기본안전과 필수성능에 관한 규격), IEC 60601-2-45(유방촬영용X선장치의 기본안전과 필수성능에 관한 규격), IEC 60601-2-54(진단용 X선장치의 기본안전과 필수성능에 관한 개별규격)에 대하여 IEC 60601-1의 3판에 맞추어 제 개정된 최신판의 동향 및 특징을 살펴보고자 하였다. 또한 현행 식품의약품안전청 고시가 IEC 60601-1의 2판이 적용된 개별규격을 참고로 하고 있어, 현행 식품의약품안전청 고시와 대비하여 그 특징을 살펴보았다. IEC 60601-1의 3판이 적용된 진단용X선장치 외 2개의 IEC 개별규격의 특징은 다음과 같다. 1) 기계적 위해요인, 특히 움직이는 부분에 대한 내용이 강화되었다. 2) 환자 선량을 표시 및 기록하도록 명시하고 있다. 3) 잠재적인 위험요소에 대해 체계적으로 관리가 가능한 위험관리 프로세스를 도입하고 있다. 4) 과거 Film-Screen System과 더불어 DR system(digital radiography system)에 대해서도 적용하고 있다. 현재 IEC 60601-1의 3판이 적용된 개별규격이 식품의약품안전청 고시로 개정될 예정이므로, 국내 시험 검사기관 및 의료기기 제조 수입업체 등에 유용한 자료가 되기를 기대한다.

Application of portable digital radiography for dental investigations of ancient Egyptian mummies during archaeological excavations: Evaluation and discussion of the advantages and limitations of different approaches and projections

  • Seiler, Roger;Eppenberger, Patrick;Ruhli, Frank
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: In the age of X-ray computed tomography (CT) and digital volume tomography (DVT), with their outstanding post-processing capabilities, indications for planar radiography for the study of the dentition of ancient Egyptian mummies may easily be overlooked. In this article, the advantages and limitations of different approaches and projections are discussed for planar oral and maxillofacial radiography using portable digital X-ray equipment during archaeological excavations. Furthermore, recommendations are provided regarding projections and sample positioning in this context. Materials and Methods: A total of 55 specimens, including 19 skeletonized mandibles, 14 skeletonized skulls, 18 separate mummified heads, and 4 partially preserved mummies were imaged using portable digital X-ray equipment in the course of archaeological excavations led by the University of Basel in the Valley of the Kings between 2009 and 2012. Images were evaluated by 2 authors with regard to the visibility of diagnostically relevant dental structures using a 4-point grading system(Likert scale). Results: Overall, the visibility of diagnostically relevant dental structures was rated highest by both authors on X-ray images acquired using a dental detector. The tube-shift technique in the lateral projections of mandibular dentition achieved the second-best rating, and lateral projections achieved the third-best rating. Conclusion: Conventional planar digital X-ray imaging, due to its ubiquity, remains an excellent method-and often the only practicable one-for examining the skulls and teeth of ancient Egyptian mummies under field conditions. Radiographic images of excellent diagnostic quality can be obtained, if an appropriate methodology regarding the selected projections and sample placement is followed.

Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교 (Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography)

  • 김영균;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Development and verification of a novel system for computed tomography scanner model construction in Monte Carlo simulations

  • Ying Liu;Ting Meng ;Haowei Zhang ;Qi Su;Hao Yan ;Heqing Lu
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4244-4252
    • /
    • 2022
  • The accuracy of Monte Carlo (MC) simulations in estimating the computed tomography radiation dose is highly dependent on the accuracy of CT scanner model. A system was developed to observe the 3D model intuitively and to calculate the X-ray energy spectrum and the bowtie (BT) filter model more accurately in Monte Carlo N-particle (MCNP). Labview's built-in Open Graphics Library (OpenGL) was used to display basic surfaces, and constructive solid geometry (CSG) method was used to realize Boolean operations. The energy spectrum was calculated by simulating the process of electronic shooting and the BT filter model was accurately modeled based on the calculated shape curve. Physical data from a study was used as an example to illustrate the accuracy of the constructed model. RMSE between the simulation and the measurement results were 0.97% and 0.74% for two filters of different shapes. It can be seen from the comparison results that to obtain an accurate CT scanner model, physical measurements should be taken as the standard. The energy spectrum library should be established based on Monte Carlo simulations with modifiable input files. It is necessary to use the three-segment splicing modeling method to construct the bowtie filter model.

전산화 단층촬영실의 산란선 측정에 대한 연구 (A Study on measurement of scattery ray of Computed Tomography)

  • 조평곤;이준협;김윤식;이창엽
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2003
  • 목 적 : 전산화 단층촬영장치는 방사선을 이용한 질병의 진단에 중추적인 역할을 하는 장비이다. 시대의 흐름과 과학기술의 발달로 전산화 단층촬영장치도 그 발전을 거듭해왔고 앞으로도 전산화 단층촬영장치를 이용한 검사는 더욱더 증가하리라 생각된다. 검사의 증가와 함께 산란선에 노출될 기회가 많아질 것이라는 생각 또한 사실이다. 이에 전산화 단층촬영실의 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 환자 검사 시 촬영실내에서의 산란선 발생률을 측정하였고 산란선의 피폭을 가장 최소화 할 수 있는 방법을 알아보고자 하였다. 대상 및 방법 : 2001년 11월부터 서울소재 13개 종합병원 및 대학병원에 설치 운용중인 전산화 단층촬영장치 25를 대상으로 하였다. 촬영조건은 피폭선량 측정시 제조업소에서 권고 하고있는 촬영조건을 사용하였고, 이때 피사체는 피폭선량 측정용 DALI CT 피폭선량 측정용 두부용 팬톰(${\phi}16\;cm$ Plexglas)과 복부용 팬톰(${\phi}32\;cm$ Plexglas)을 사용하였다. 산란선의 측정은 환경방사선 측정용 Survey Meter인 Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion chamber, S/N 21740에 Reader(Radiation Monitor Controller model 2026)과 G-M Survey를 이용하였다. 산란선의 측정위치는 전산화 단층촬영실에서 방사선 작업종사자가 주로 활동하는 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 피사체 스캔시 등선량중심점(isocenter)으로부터 100 cm되는 지점에서 측정하였다. 결 과 : 각 병원에서 설치 운용중인 전산화 단층촬영실내 작업환경은 해당병원의 상황에 따라 많은 차이를 보이고 있었고 산란선의 발생유무는 다음과 같았다. 1) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 제어실내 환자 보기창 사이의 거리는 평균 377 cm이였고 이때 산란선은 거의 검출되지 않은 곳에서부터 약 100 mR/week까지 다양한 분포를 보였으나 주당 허용선량인 $2.58{\times}10^{-5}\;C/kg$(100 mR/week)이내의 조건을 만족하고 있었다. 2) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 환자 및 보호자가 출입하는 출입문 외측까지의 거리는 평균 439cm이었고, 이때 산란선은 거의 검출되지 않은 곳부터 다양한 분포를 보였으나 대부분의 병원에서 주당허용선량인 $2.58{\times}10^{-6}\;C/kg$(10 mR/week)이내의 조건을 만족하고 있었다. 3) 피사체를 스캔할 때 등선량중심점(isocenter)에서부터 100 cm되는 곳에서의 산란선량은 장비에 따라 많은 차이가 있었다. 결 론 : 진단용 방사선발생장치에서 전산화 단층촬영장치의 이용은 나날이 증가하고 있고 다른 일반 X-선 촬영과 비교했을 때 진단영역이 매우 높지만 방사선으로 인한 피폭과 산란선에 노출될 가능성이 매우 높다. 전산화 단층촬영실에서 산란선으로부터 조금이라도 자유로워지기 위해서는 설계단계에서부터 충분한 공간 확보가 우선되어야하고 모든 검사에서 방사선사는 최소의 선량으로 최상의 영상을 제공할 수 있는 다양한 기술개발에 더욱 노력을 아끼지 말아야 할 것으로 생각된다.

  • PDF

영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석 (Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology)

  • 홍동희;김형균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.421-427
    • /
    • 2016
  • 경상북도 소재 100병상 이상의 3개 종합병원 응급실에 설치된 일반촬영장비와 CT장비에 대한 세균 오염도 검사를 실시하여 감염관리에 대한 기초자료를 제공하고 관리방안을 제안하고자하였다. 2015년 12월 1일부터 12월 31일까지 이루어졌으며 경상북도 소재 응급실내의 일반촬영장비와 CT장비를 대상으로 하였다. 일반촬영장비는 업무종사자가 가장 많이 사용하는 control box 위, 노출 버튼 위, 환자의 피부 접촉 부위인 테이블 위 전체와 stand bucky의 grid 위 및 턱 올려놓은 곳 등 총 4곳을 수집하였다. CT장비는 촬영실 업무종사자가 가장 많이 사용하는 control box위와 X-선 노출 버튼, 환자의 피부 접촉 부위인 환자 테이블 위 전체, gantry inner 등 총 3곳을 수집하였다. 영상의학과 응급실내 일반촬영장비에서 검출된 표면 오염 균주는 Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), incubator에서 48시간 배양 후 자라지 않은 세균은 25%를 차지하였다. 또한 영상의학과 응급실 내 CT장비의 검출된 표면 오염 균주는 Stenotrophomonas maltophilia(11%), Enteococcus faecalis(11%), Escherichia coli(11%), incubator에서 48시간 배양 후 자라지 않은 세균은 67%로 대부분이었다. 영상의학과 일반촬영장치의 Stand bucky-grid와 Stand bucky 상연에서 대부분의 세균이 발견되었고, CT장비의 검체 수집 부분 중 Patient table에 집중되어 검출되었다. 이는 여러 질환을 갖고 있는 환자에 의해 오염된 것을 의미하며 균주 모두 면역력이 저하된 환자에게는 치명적인 질환을 일으킬 수 있다. 그러므로 검사 전후 70% 알코올 소독을 통해 감염예방을 하여야 한다.