구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

의료분야 진단용방사선발생장치의 품질관리 (Quality Control of Diagnostic X-ray Equipment in Medical Field)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.159-164
    • /
    • 2021
  • 진단용방사선발생장치를 이용한 검사는 영상의학과에서 인체 내 정보를 파악하기 위한 가장 유용한 진단장비 중 하나로 신뢰도가 매우 높다. 이와 같은 이유로, 최근에는 영상의학과 영역의 진단 검사 장비를 이용한 검사 건수가 매년 증가하고 있다. 또한, 검사 건수 증가는 장치의 빠른 노화를 불러일으키고 이로 인해 장치에 대한 정도관리(quality control, QC)의 중요성이 대두된다. 특히, 진단용방사선발생장치를 이용한 검사에서 정도관리란 검사시작부터 검사가 끝날 때 까지 발생할 수 있는 모든 문제점을 사전에 알아내고 대처하여 신뢰가 확보된 영상을 획득하여 제공하는 과정에 있는 일련의 모든 활동을 의미한다. 이에 본 연구에서는 진단용방사선발생장치를 이용한 검사에서 정도관리에 대해보고 한다.

정류방식에 따른 진단용 X-선 장치의 출력비교 (A Comparative Study on Output of Four Type Diagnostic X-ray Equipments)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

사업장 단체검진 시 흉부촬영의 방사선피폭 최적화 및 안전에 대한 고찰 (- A Study on Safety of the Radiation Exposure Dose Optimization at Chest B-ray Examinations -)

  • 임재동;강경식
    • 대한안전경영과학회지
    • /
    • 제6권3호
    • /
    • pp.87-97
    • /
    • 2004
  • The National Health Insurance Act, the Industrial Health Act and the School Health Act require chest radiography at least once a year. In chest radiographic examination, most group examinations use indirect X-ray primarily aiming at diagnosing diseases and enhancing people's health. This study purposed to minimize radiation exposure dose by comparing it between direct and indirect chest X-ray studies. According to the result of comparing and analyzing radiation exposure dose, the average incident dose and penetrating dose were 0.929μGy and 0.179μGy respectively in direct chest X-ray and 6.807μGy and 1.337μGy in indirect chest X-ray In order to minimize radiation exposure dose at direct and indirect chest X-ray, indirect X-ray should be excluded from group examination if possible. Moreover, it is necessary to control the quality of equipment (Q/A & Q/C) systematically and to avoid using unqualified equipment in order to reduce radiation exposure dose.

40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성 (Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.247-252
    • /
    • 2008
  • 휴대용 XRF(X-Ray Fluorescence) 장치에 적용하기 위하여 개발한 투과 양극형 x-ray tube를 이용하여 XRF 실험을 하고, x-ray tube가 XRF data에 미치는 영향을 조사하였다. W-target tube와 Rh-target tube를 이용하여 측정한 XRF data는 알려진 결과와 잘 일치하였다. 35 kV와 관전압과 $40{\mu}A$의 관전류에서 W-target tube로 측정한 Fe $K_{\alpha}$-line의 FWHM은 약 180 eV로써, 이 값은 물질의 성분분석을 하기에 충분한 것으로 확인하였다. XRF data와 x-ray tube의 적분강도 곡선을 비교 분석해 본 결과, 휴대용 XRF 장치에는 W-Target tube보다는 Rh-Target tube를 사용하는 것이 더 유리함을 밝혀내었다.

이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가 (The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray)

  • 이해정;김호성;김은혜
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

경북 지역 의원급의 X선 발생장치 정도관리 실태 (Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area)

  • 박정규
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.267-275
    • /
    • 2010
  • X선 발생장치의 정도관리는 의료기관의 설립형태에 따라 가장 큰 차이가 있으며, 장치의 보유율은 1차 의료기관에서 가장 많이 보유한 반면 정도관리에 대한 인식과 관리는 소홀하다 할 수 있다. 본 연구에서는 2010년 1월 4일부터 2010년 9월 3일까지 경북 지역을 4개의 권역으로 나누고, 각 시별로 4곳을 임으로 선정하였다. 전체 16곳에 있는 의원급 의료기관 중 10년 이상 된 X선 발생장치를 보유한 8곳과 10년 이하의 X선 발생장치를 보유한 8곳를 그 대상으로 하였으며, 정도관리의 필수 항목 5가지를 시험하였다. 접지 설비 확인시험에서는 10년 이상 된 X선 장치를 보유한 한 곳이 별도의 접지선을 구비하지 않았으며(6.25%), 외장 누설전류시험에서는 모두 적합 하였다. 조사선량 재현성 시험에서는 10년 이상 된 X선 발생장치를 보유한 4곳(25%)과 10년 이하의 X선 발생장치를 보유한 1(6.25%)곳이 부적합 하였다. 관전압의 정확도 시험에서는 10년 이상 된 X선 발생장치를 보유한 5곳(31.25%)과 10년 이하의 X선 장치를 보유한 2곳(12.5%)이 부적합 하였다. 관전류와 관전류량 시험에서는 10년 이상 된 X선 장치를 보유한 3곳(18.75%)과 10년 이하의 X선 장치를 보유한 1곳(6.25%)이 부적합 하였다. 본 연구 결과 10년 이하의 X선 발생장치를 보유한 의원급 의료기관 보다 10년 이상 된 의원급 의료기관의 X선 발생장치의 정도 관리 실태는 심각한 수준 이였다. 검사 결과를 바탕으로 행정적, 기술적인 조치들이 신속하게 이루어져야 할 것이다. 또한 의원급의 사업주나 장치 담당자들의 의식 전환이 필요 하며 그러기 위해서는 오래된 장비이거나 자주 사용하지 않는 장비일수록 정기검사주기를 1~2년 단위로 개정하여야 하고, 정기적인 정도 관리 교육 프로그램을 실시하여야 할 것으로 사료된다.

지진을 대비한 방사선기기의 고정방법 (Provision for Earthquake with Tie up Device in X-ray Equipment)

  • 김정민;관본유남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.39-48
    • /
    • 2002
  • Earthquake are not frequent in korea but exist. The purpose of this study is to make a fixation(tie up) device against earthquake for radiologic department installation. It is considered that the device will prevent the X-ray equipment fall down, slip, Jumping therefor save the X-ray equipment itself and making possible to examine patients even when occuring earthquake, Discussion on how to make and how to set up was researched.

  • PDF

개선된 X선 중심선속정렬평가 측정법 (Improved X-ray Center Beam Alignment Evaluation Method)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.827-832
    • /
    • 2020
  • 영상의학과 진료에 자주 이용되는 X선 장비는 임상에서 가장 보편화되어 있고 가장 많이 사용되는 장비이다. 장비는 지속적인 품질관리를 통해서 환자에게 정확한 정보를 제공해야 한다. 수동으로 계측 할 경우 재현성이 떨어지고 평가결과에 대한 신뢰도에 문제가 있을 수 있다.본 연구에서는 현재 임상에서 사용되고 있는 진단용 X선발생장치의 X선관 초점과 가변 조리개의 중심선속이 얼마나 일치하는지를 자동화된 프로그램을 통해서 계측하고 평가하고자 하였다. 실험결과, 두 개의 평가용 중심점 좌표를 계산하는데 성공하였고 두 점간 거리를 픽셀단위로 계산하여 판정에 적용하였다. 중심선속 일치정도가 정상 각도이내에 존재하는지 비정상 범위인지에 대한 자동판정 값을 제시하였다. 본 연구의 결과는 엑스선장치의 품질관리에 도움을 줄 것으로 판단한다.

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF