• Title/Summary/Keyword: X ray tube

검색결과 516건 처리시간 0.031초

흉총창에 의한 심방파열 치험 2례

  • 이두연;곽상룡
    • Journal of Chest Surgery
    • /
    • 제13권1호
    • /
    • pp.60-65
    • /
    • 1980
  • We have experienced 2 cases of the hunshot wound sof the chest involving cardiac injuries at department of the thoracic surgery, Capital Armed Forces General Hospital during I year from April I 1979 to Jan. 1980. In one case of two patients , he was a 22 years old man who was transported to this emergency room 4 hour 10 minutes after having gunshot wound of the left chest by helicopter. Physical examination showed small inlet in left 3rd ICS and left parasternal border, large outlet in left 8th ICS and left scapular line, no breath sound on left side and distant heart sound. chest roentgenography demonstrated marked pleural effusion in left side and mediastinum shifted to right. As soon as chest X-ray was taken, the bleeding through penetrating wound became profuse and cardiac arrest ensued. Closed chest cardiac massage was started and vigorous transfusion continued, but no effective cardiac activity could not be obtained. The patient was pronounced dead due to exsanguinating hemorrhage from wuwpected cardiac wounds. In this critically injured patient with evidence of intrathoracic hemorrhage and suspected cardiac penetration, only emergency thoracic exploration and immediate surgical control of bleeding points might offer the maximum possibility of survival. The other case was a 23 years old man who was transferred to the emergency room 4 hours 50 minutes after having kmultiple communicated fractures of sternum and linear fracture of right mandible by a missile. Examination revealed about 30% skin loss of the anterior chest wall, weak pulse of 96 beats/min., distant heart sound and decreased breath sounds bilaterally. finding on the chest X-ray films showed multiple sternal fractures, marked pericardial effusion indicating hemopericardium. So, the patient was moved immediately to the operation room where, after endotracheal tube inserted, a median sternotomy was performced. A hemorrhagic congestion of the right upper lobe and marked bulging pericardium were disclosed. The pericardium was opened anterior to right phrenic nerve and exsanguinating hemorrhage ensued from the 0.5cm lacerated wound in the auricle of right atrium. The rupture site of right atrium was occluded with non-crushing vascular clamps and then was over sewn with interrupted sutures. It was thought to be highly possible that he was alive long enough to have cardiorrhaphy because of cardiac tamponade, which prevented exsanguinating hemorrhage. He was taken closed reduction for linear fracture of right mandible 2 weeks after repair of ruptured right auricle in dental clinic. This patient's post-operative course was not eventful.

  • PDF

두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가 (Image Quality and Dose Assessment According to Examination Mode during Head CT Examination)

  • 강헌효;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.437-444
    • /
    • 2021
  • 두경부 CT 검사시 팬텀을 이용하여 Helical mode, High Pitch Mode, Volume Axial Mode 사용하여 획득한 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Volume Axial Mode의 유용성을 평가해보고자 한다. 두경부 CT 검사 시 각 mode에 따른 70 kVp, 80 kVp, 100 kVp 관전압에 따라 검사를 시행하였다. 사용 장비로는 GE사의 Revolution(GE Healthcare, Wisconsin USA) 모델과 iMED X-ray Phantom을 이용하였다. 검사 Mode에따른 kVp별로 얻어진 영상을 이용하여 팬텀의 피폭선량을 비교하였으며, 각 영상에 ROI를 설정해 신호대 잡음비와 대조도대 잡음비를 산출하여 영상의 화질을 비교하였다. Volume Axial Mode를 사용하여 검사하였을 때 팬텀의 피폭선량이 Helical에 비해 17.12% 낮게, High Pitch에 비해 5.35% 낮게 측정되었고, 신호대 잡음비와 대조도대 잡음비가 향상되었다. Volume Axial Mode는 고속 회전 스캐너를 이용하여 테이블의 이동이 없이 조사시간을 줄이고, High Pitch Mode와 Helical Mode를 사용했을 때 보다 팬텀의 0.28초의 단시간에 영상을 획득하여 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다. 또, 몸이 불편한 환자의 촬영이나 긴급환자의 CT 촬영에 있어서 Volume Axial Mode의 빠른 검사시간은 최대의 장점이라고 볼 수 있다.

Haas 촬영법에서 선예한 영상 획득을 위한 연구 (A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection))

  • 안준호;한재복;송종남;김인수
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.319-325
    • /
    • 2022
  • 본 연구는 머리뼈 후전축방향 촬영(Haas)에서 선예한 영상을 얻어 진단하고자 Skull -Phantom을 이용하여 자세 각도를 변경하여 영상을 획득한 후 대학병원 영상의학과에 근무한 방사선사 5명에게 주관적 영상평가한 결과 머리를 엎드린자세에서 머리 뒤쪽의 뒤통수점에서 4 cm 아래로 내리고 머리쪽을 향하여 25° 입사하여 촬영시에 뒤통수뼈와 큰구멍내에 투영된 안장등, 뒤침대돌기등 영상평가 점수가 20점으로 높았으며, 뒤통수점에서 아래로 8 cm 내려서 머리쪽으로 30° 입사 시 바위모뿔대칭의 음영, 바위능선과 시상봉합, 시웃자봉합 등 19점으로 높은 영상평가를 받았다. 또한, 점수 유의성을 검증하였으며, Cronbach Alpha 값이 0.789 신뢰도가 좋음을 평가 받았다. 영상의 관심영역(ROI)을 설정하여 신호대잡음비(SNR)를 산출한 결과 머리 뒤쪽 뒤통수점에서 4 cm 아래로 내리고 머리쪽으로 25° 입사 시 5.957로 가장 높으며, 뒤통수점에서 아래로 8 cm 내려서 입사 시는 머리쪽으로 30° 기울여 촬영하였을 때 6.430으로 가장 높았다. 연구결과에 의하면 머리 후전축방향 촬영시 뒤통수뼈와 안장, 뒤침대돌기의 선예한 영상을 얻기 위해서는 뒤통수점에서 아래로 4 cm 에서 머리쪽으로 25° 입사하여 촬영하고 바위모뿔대칭의 음영과 바위능선과 시상봉합, 시웃자봉합의 선예한 영상을 얻기 위해서는 뒤통수점에서 아래로 8 cm 내려서 머리쪽으로 30° 기울여 촬영한다면 임상에서 활용에 도움이 있으리라 사료된다.

치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구 (The Study on the Protection and Actual Condition of Using the Dental X-ray Unit)

  • 강은주;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF

CBCT와 panorama 촬영시 위치에 따른 선량 비교 (Comparison of Dose Depending on the Position when Shooting Panorama and CBCT)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.175-179
    • /
    • 2013
  • 파노라마와 CBCT 같은 회전하는 방사선 발생장치에서 방사선작업종사자와 보호자의 적절한 피폭 방어 대책을 알아보고자 위치에 따른 방사선 조사선량을 비교 분석하였다. 사용된 장치로는 파노라마 DP-90-P PAX-500(Vatech, Korea)와 CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea)을 사용하였다. 조사선량 측정기는 Ion chamber model 2026과 Reader기 20X5-60E를 사용하였다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 실험결과 파노라마는 검사가 처음 시작하는 A지점이 81${\mu}R$ 으로 가장 높게 나왔고, 검사가 끝나는 D점이 53${\mu}R$ 으로 가장 낮게 나왔다. CBCT의 경우는 검사가 끝나는 D지점이 1,021${\mu}R$ 으로 가장 높게 나왔고, 검사가 시작하는 A지점이 809.67${\mu}R$ 으로 가장 높게 측정되었다. 부득이하게 보호자나 방사선작업종사자가 환자를 잡고 검사해야 할 경우에는 피폭선량이 가장 많은 지점을 피해서 X선관이 회전하기 시작하는 지점과 끝나는 지점의 가운데 위치해야 할 것이다. 그리고 장비의 특성상 기계의 반대편이며, 환자의 측면에서 지지하는 것보다 후방에서 지지하는 것이 가장 안전할 것이고, 적절한 방호기구를 착용해야 할 것이다.

Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구 (A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy)

  • 송종남;설광욱;홍성일;최정구
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.135-141
    • /
    • 2011
  • X선에 대한 피폭을 최소화 하려는 앞치마는 차폐 성능이 좋지 않으면 방사선 작업종사자나 환자에게 불필요한 피폭을 줄 수 있으며 나아가 방사선 만성 장해를 유발시키기도 한다. 이를 방지하기 위하여 제조사에서는 0.25mm이상의 납 당량을 가진 앞치마을 제작한다. 본 논문에서는 앞치마을 제조사별, 납 당량별로 분류하여 차폐성능을 측정, 우수한 앞치마를 구비하는데 기초자료를 제공하고 성능 평가 방법의 접근을 용이하게 하고자 한다. 0.05mm의 Pb과 4개의 제조사(H, X, I, J)에서 제작된 앞치마을 3종류의 납 당량별(0.50mmPb, 0.35mmPb, 0.25mmPb)로 분류하고 Apron은 크게 Clavicle part, Chest part, Abdomen part, Pelvis part로 구분하여 투시촬영장치를 이용, 방사선 투과율, 차폐율과 표준편차를 측정하였다. 0.5mmPb 앞치마의 방사선투과율과 차폐율을 측정한 결과 I사의 앞치마가 가장 우수한 97.96%의 차폐율을 보였으며, J사의 앞치마는 96.25%의 차폐율을 보이며 가장 저조하였다. 0.35mmPb 앞치마의 경우 I사의 Apron이 96.79%의 가장 우수한 차폐율을 보였으며 A사의 앞치마는 가장 저조한 95.81%의 차폐율을 보였다. 0.25mmPb 앞치마의 경우 X사의 앞치마가 가장 우수한 90.91%의 차폐율을 보였으며 H사의 앞치마는 가장 저조한 88.82%의 차폐율을 나타냈다. 또한 0.5mm 납을 함유한 앞치마의 차폐율에 대한 표준편차는 X사(0.125)와 I사(0.190)가 가장 낮게 나타났고 J사(0.447)가 가장 높게 나타났으며, 0.35mm 납을 함유한 앞치마는 I사(0.231)가 가장 낮았다. 0.25mm 납을 함유한 앞치마는 X사(0.364)로 다른 제조업체의 앞치마보다 표준편차가 가장 작았다. 일정한 납 당량이 함유된 앞치마는 지금까지 방사선으로부터 피폭을 방지하는 보편적이며 일반적인 보호 장구이다. 그러므로 환자, 보호자 또는 방사선 관련 작업종사자는 방사선 피폭을 최대한 방지하기 위하여 양질의 앞치마를 사용하여야 할 것이며 이러한 실험적인 방법을 통하여 객관적이며 현실적인 차폐율을 평가해야 할 것이다.

디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석 (An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector)

  • 유영은;임청환;고주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.93-100
    • /
    • 2014
  • 최근 무선 LAN통신 기능을 이용하여 보다 간편하고 빠르게 디지털 방사선 영상을 획득할 수 있는 디지털 무선 이동촬영장치가 개발되어 많은 편의성을 제공하고 있다. 응급 또는 중환자를 대상으로 시행하는 이동촬영(Portable)검사 특성상 발생할 수 있는 초점-격자 간 중심변위와 피사체의 검출기내 위치변위가 영상화질에 미치는 영향을 평가하여 디지털 무선 검출기의 가이드라인을 제시하고자 한다. 본 연구에서 사용된 장비는 Elmo-T6 Digital Mobile X선시스템(SIMAZU사), el' Tor($14{\times}17$"Wireless detector), 격자(10:1), Chest & head phantom을 사용하였다. 선량증가에 따른 후처리 영상과 초점-격자 간 중심변위와 두부팬텀의 위치변위 영상을 획득한 후 디지털 영상분석 프로그램 Image J를 사용하여 영상을 비교분석 평가하였다. 선량증가에 따른 영상의 변화에서 0.5 mAs의 선량에서는 영상이 거칠고, 적정선량인 1~2 mAs에서 시각적으로 영상의 차이를 알 수 없었고, 특히 2.5 mAs 부터 픽셀 평균값이 급격히 감소하여 대조도에 영향을 미치는 것으로 나타났다. 3 mAs 이상에서는 폐부분의 포화현상으로 대조도가 떨어졌다. Image J 프로그램을 이용한 분석결과 초점-격자 간과 두부팬텀의 중심의 위치변위가 커질수록 낮은 픽셀값의 빈도수가 증가하여 표면도의 윤곽형태가 사라져 대조도에 영향을 미치는 것으로 나타났다. 중환자의 특성상 환자 자세의 어려움, 움직임, 호흡 및 X선관의 변위, 촬영거리의 적용여부에 따라 영상화질을 변화시킬 수 있다는 사실을 방사선사는 정확히 인지하여 검사에 임해야 할 것으로 사료된다.

액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구 (Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound)

  • 장서구;한수철;강성진;임성욱;이성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.461-468
    • /
    • 2017
  • 본 연구는 진단용 X선 에너지 영역에서 고순도의 납 0.5mm 와 실리콘(Si)과 이산화티탄($TiO_2$)을 이용한 X선 융합차폐체의 선량을 측정하고 차폐율을 비교 측정하였다. 실험을 위하여 실리콘(Si)과 이산화티탄($TiO_2$)을 혼합하여 1 mm 두께의 패드형 차폐체를 제작하고, 차폐체의 두께를 1mm 씩 증가시키며 X선을 조사하여 0 mR이 될 때까지 선량을 측정하였다. KS A 4025의 권고에 따라 X선 조사조건은 각각 60 kVp 20 mAs, 100 kVp 20 mAs로 하였으며, 두 개의 관전압 조건에서 차폐체가 없을 경우의 조사선량을 기준으로 차폐체가 있을 경우의 선량과 비교하여 차폐율을 구하였다. 두께 0.5 mm 납판 차폐체의 차폐율은 60 kVp에서 95.92%, 100 kVp에서 85.26%로 측정되었고, 실리콘(Si)과 이산화티탄($TiO_2$)패드 차폐체를 적용하였을 경우 60 kVp, 20 mAs 조건에서 두께가 11 mm 이상일 때 10회 조사 평균선량은 1.77 mR, 차폐율은 납판 0.5 mm 차폐체와 등가의 차폐율을 나타내었으며, 13 mm에서 측정선량이 0 mR이 되었다. 100 kVp, 20 mAs 조건에서는 17 mm 두께에서 납 0.5 mm 차폐체와 등가 이상의 차폐율이 관찰 되었고 23 mm 두께에서 100% 의 차폐율을 관찰할 수 있었다. 본 연구 결과를 통해 실리콘-이산화티탄 화합물은 실리콘의 물성이 그대로 존재하면서 금속화합물과 융합할 수 있다는 결과를 얻었으며, 이후 방사선 흡수가 더 뛰어난 금속화합물등과 혼합할 경우 납의 위해성을 포함하지 않으며, 재료와 가공성에서 경제적이며, 실리콘의 강점을 살려 탄성과 유연성이 뛰어난 저선량용 방사선 차폐재의 제작 가능성을 확인해 볼 수 있었다.

전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가 (Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System)

  • 우민선;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.455-464
    • /
    • 2012
  • 본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.

좌측 완전 심낭결손증을 동반한 Communicating Bronchopulmonary Foregut Malformation - 1예 보고 - (A Communicating Bronchopulmonary Foregut Malformation Associated with Absence of the Left Pericardium - A case report -)

  • 유동곤;박종빈;강필제;이종혁;김종욱
    • Journal of Chest Surgery
    • /
    • 제40권11호
    • /
    • pp.793-797
    • /
    • 2007
  • Communicating bronchopulmonary foregut malformation (CBPFM)은 매우 드문 선천성 기형으로 격리된 호흡계 조직과 식도 또는 위장 사이의 누관이 특징적이다. 원시위장관에서 기원한 부속의 폐조직이 모든 종류의 bronchopulmonary furegut malformation 발생의 중요한 요인이 된다. 반복되는 폐렴이 있는 환자의 chest X-ray에서 낭성 병변이 보인다면 CBPFM을 생각해봐야 하며, 진단적 방법으로 식도조영술, 기관조영술, 컴퓨터 단층촬영, 자기공명영상 그리고 혈관조영술 등이 도움이 된다. 치료는 수술적 제거가 권장되며 예후도 좋다. 좌측 완전 심낭결손증과 동반되었으며, 이중식도에 연결된 외엽성 폐격리증과 기관지성 낭종을 보인 CBPFM 1예를 보고한다.