• Title/Summary/Keyword: X

Search Result 46,291, Processing Time 0.078 seconds

Two Faces of Entrepreneurial Leadership: The Paradoxical Effect Reflecting Followers' Regulatory Focus (기업가적 리더십의 양면성: 구성원의 조절 초점 성향에 따른 패러독스 효과)

  • Sang-Jib Kwon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.4
    • /
    • pp.165-175
    • /
    • 2023
  • In venture creation research, studying 'entrepreneurial leadership' is important for uncovering and comprehending the underlying causal process in innovative behavior performance. Although previous studies provide that entrepreneurial leadership enhances followers' innovative behavior, there is few research on entrepreneurial leadership and followers' characteristics interaction. The present study's focus is paradoxical effects of entrepreneurial leadership on self-efficacy and innovative behavior. On the basis of individual regulatory focus, this study suggests that interaction effects of entrepreneurial leadership and followers' regulatory focus differed in promotion view and prevention view followers' innovative behavior. To strengthen the casual mechanism, this study conducted in priming experiment method using employees in SMEs. This study used a 2(entrepreneurial leadership vs. control) x 2 (regulatory focus: promotion vs. prevention) between-participants design. The results of this study provide that (1) Individuals in promotion focus especially benefited from entrepreneurial leadership in terms of its effect on their self-efficacy and innovative behavior; (2) whereas entrepreneurial leadership was negatively related to self-efficacy and innovative behavior of followers' prevention focus. In sum, results of the present study supporting evidence for hypotheses, combined effect of entrepreneurial leadership and regulatory focus on innovative behavior through self-efficacy. Experimental results confirmed hypotheses of this study, revealing that promotion focus show more innovative behavior than prevention focus when their leaders' leadership style is entrepreneurial leadership. Also, the paradoxical effect of entrepreneurial leadership and regulatory focus of followers on innovative behavior was mediated by followers' self-efficacy. This study helps explain how leaders' entrepreneurial leadership boost followers' innovative behavior, particularly for those employees who have promotion focus. The current study contributes to the theory of entrepreneurial leadership and regulatory focus and innovation literature. Findings of this study shed light on the organizational processes that shape innovative behavior in venture/startup corporations and provide contributions for venture business field.

  • PDF

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Mineralogical Analysis of Calcium Silicate Cement according to the Mixing Rate of Waste Concrete Powder (폐콘크리트 미분말 치환율에 따른 이산화탄소 반응경화 시멘트의 광물상 분석)

  • Lee, Hyang-Sun;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.181-191
    • /
    • 2024
  • In the realm of cement manufacturing, concerted efforts are underway to mitigate the emission of greenhouse gases. A significant portion, approximately 60%, of these emissions during the cement clinker sintering process is attributed to the decarbonation of limestone, which serves as a fundamental ingredient in cement production. Prompted by these environmental concerns, there is an active pursuit of alternative technologies and admixtures for cement that can substitute for limestone. Concurrently, initiatives are being explored to harness technology within the cement industry for the capture of carbon dioxide from industrial emissions, facilitating its conversion into carbonate minerals via chemical processes. Parallel to these technological advances, economic growth has precipitated a surge in construction activities, culminating in a steady escalation of construction waste, notably waste concrete. This study is anchored in the innovative production of calcium silicate cement clinkers, utilizing finely powdered waste concrete, followed by a thorough analysis of their mineral phases. Through X-ray diffraction(XRD) analysis, it was observed that increasing the substitution level of waste concrete powder and the molar ratio of SiO2 to (CaO+SiO2) leads to a decrease in Belite and γ-Belite, whereas minerals associated with carbonation, such as wollastonite and rankinite, exhibited an upsurge. Furthermore, the formation of gehlenite in cement clinkers, especially at higher substitution levels of waste concrete powder and the aforementioned molar ratio, is attributed to a synthetic reaction with Al2O3 present in the waste concrete powder. Analysis of free-CaO content revealed a decrement with increasing substitution rate of waste concrete powder and the molar ratio of SiO2/(CaO+SiO2). The outcomes of this study substantiate the viability of fabricating calcium silicate cement clinkers employing waste concrete powder.

A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU (경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구)

  • Geun-Woo Jeong;Hae-Suk Kim;Jae-Hyeong Park;Sung-Hyun Joo;Jae-Gyeong Choi;Se-Im Cheon;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2024
  • The purpose of this study is to examine the radioprotection effect of mixtures of selenium and arginine for development of radioprotection agents that can minimize radiation damage to police special operation unit in the event of radioactive terrorism. In this study 72 male rats were classified into 4 groups: normal group(NC Group), selenium and arginine mixtures administration group(SeAr Group), radiation exposure group(IR Group), and selenium and arginine mixture administration group followed by radiation exposure(SeAr+IR Group). The 7Gy of X-ray was irradiated to whole body of SD rats. And selenium and arginine were dministered orally at 3mg/kg and 150mg/kg once a day for 14 days. And then hematological and histological analyzes were performed on days 1, 7, and 21 after radiation exposure. In hemotological analysis, significant radioprotection wes observed in lymphocytes(p<0.05) on day 1, platelet(p<0.01) on day 7, red blood cell(p<0.01) on day 21 of radiation exposure in SeAr+IR group compared to IR group. In histological analysis, it was observed that the border of small crypt cells in the small intestine was less collapsed and the length of small crypts was relatively recovered on day 7 and showed that the number of cells and cell wall thickness were better in the prostate on day 21 in SeAr+IR group compared to IR group. Therefore, it is judged that selenium and arginine mixtures have radioprotection effect on blood and tissues due to radiation exposure. it will be helpful for research on radioprotection agents to reduce radiation damage to police special operation unit.

A Study on the Classification System of Cadastral Cultural Heritage : Focusing on LX museum collection (지적 문화유산 분류체계 연구 - LX국토정보박물관 소장품을 중심으로 -)

  • Kim, Ji-Hyun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.54 no.1
    • /
    • pp.63-74
    • /
    • 2024
  • The fundamental basis for revitalizing cultural resources and developing content is national heritage(cultural property). In national heritage, cultural heritage is a tangible cultural heritage that represents the uniqueness of history and tradition, identity, and changes in life. In the case of museums, the collections (a museum-owned cultural heritage) represent the unique characteristics of the institution. In South Korea, it is recommended that museum collections be registered and used in the Cultural Heritage Standard Management System so that cultural heritage can be managed and utilized in connection with academics, industry, and administration. However, due to a lack of awareness of modern and contemporary heritage, the thematic classification chronology of the system was set mainly before the Joseon Dynasty, and a cultural heritage classification system suitable for national land information has not been established. Therefore, this study aims to propose a classification system for cadastral cultural heritage, based on the modern era when cadastral terminology was first used, using the cultural heritage owned by the LX Museum. Cadastral cultural heritage is characterized by the fact that although it is a field of specialized technology, the surveying or the production of it is not done by specific individuals only, and that while the production is professional, there are many educational aspects in its use. Therefore, unlike other specialized museum collections that are classified based on the functional aspects of their production methods, intended use, and creators, the classification method for cadastral cultural artifacts should be based on the characteristics of the cadastral tools and the outputs. This classification follows a three-tier stages with reference to the items in the Cultural Heritage Standard Management System. This classification aims at the effective use of knowledge by categorizing concepts and systematizing the subjects of data into a series of orders. A safe conservation and management environment for cadastral cultural heritage can be established, and academic and socio-cultural interpretation of the collection is possible by this classfication. Moreover, It is also expected to serve the basis for the national land information as well as searching for the national land information research, planning a exhibition, and the field of education in museum.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Chest CT Findings of COVID-19 Patients with Mild Clinical Symptoms at a Single Hospital in Korea (경증의 임상 소견을 보이는 COVID-19 환자들의 흉부 CT 소견)

  • Woon Young Baek;Young Kyung Lee;Suhyun Kim;Chorom Hahm;Mi Young Ahn;Dong Hyun Oh;Jae-Phil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.139-151
    • /
    • 2021
  • Purpose To retrospectively evaluate the chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in patients with mild clinical symptoms at a single hospital in South Korea. Materials and Methods CT scans of 87 COVID-19 patients [43 men and 44 women; median age: 41 years (interquartile range: 26.1-51.0 years)] with mild clinical symptoms (fever < 38℃ and no dyspnea) were evaluated. Results CT findings were normal in 39 (44.8%) and abnormal in 48 (55.2%) patients. Among the 48 patients with lung opacities, 17 (35.4%) had unilateral disease and 31 (64.6%) had bilateral disease. One (2.1%) patient showed subpleural distribution, 9 (18.8%) showed peribronchovascular distribution, and 38 (79.2%) showed subpleural and peribronchovascular distributions. Twenty-two (45.8%) patients had pure ground-glass opacities (GGOs) with no consolidation, 17 (35.4%) had mixed opacities dominated by GGOs, and 9 (18.8%) had mixed opacities dominated by consolidation. No patients demonstrated consolidation without GGOs. Conclusion The most common CT finding of COVID-19 in patients with mild clinical symptoms was bilateral multiple GGO-dominant lesions with subpleural and peribronchovascular distribution and lower lung predilection. The initial chest CT of almost half of COVID-19 patients with mild clinical symptoms showed no lung parenchymal lesions. Compared to relatively severe cases, mild cases were more likely to manifest as unilateral disease with pure GGOs or GGO-dominant mixed opacities and less likely to show air bronchogram.