• Title/Summary/Keyword: Wrist Motion

Search Result 203, Processing Time 0.023 seconds

The Reliability of Kinematic Analysis for Distal Upper Extremity in Normal Person (정상인의 상지 원위부에 대한 운동학적 분석의 신뢰도)

  • Byun, Jae-Hyun;Hong, Wan-Ki
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Purpose: To evaluate statistical differences among three measurements of range of motion (ROM) with Rapael Smart Glove (RSG) group 1, 2 and manual goniometer group. To investigate reference value of the kinematic analysis for range of motion (ROM) of distal upper extremity with Rapael Smart Glove (RSG). Methods: Sixteen normal persons without limitation of motion (LOM) enrolled in the study. The study was performed at two separate times and by two investigators on 16 normal adults. We compared ROM with RSG for measuring joint angles. We compared degrees of forearm supination/pronation, wrist flexion/extension and radial deviation/ulnar deviation during ROM of 16 participants using RSG. After one week, degrees of each motion were measured in the same way by other investigator to evaluate the reliability. Results: Statistical differences among three groups were showed. Most results of paired t-test between two RSG groups were over 0.05 and exceptions are supination, extension, and finger %. Conclusion: Our findings demonstrate that ROM of normal persons obtained by kinematic analysis with RSG are not valid as normal reference value for distal upper extremity motion. But, the reliability of between two RSG groups was showed with paired t-test and Pearson's correlation except supination, extension and finger %.

Evaluation of the Fit and Motion Suitability for Korean Female Combat Uniforms (여군 전투복의 치수 및 동작적합성 평가)

  • Okkyung Lee;Yejin Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.4
    • /
    • pp.696-710
    • /
    • 2023
  • This study investigated the problems of Korean female combat uniforms and collected primary data for developing new combat uniforms with improved functionality. We analyzed fit and motion suitability by administering a questionnaire evaluating the current uniforms to 20 Korean female soldiers. The evaluation of fit suitability found that satisfaction with the combat uniforms was generally high. However, short sleeve length, large wrist circumference, small hip circumference, large ankle circumference, and low crotch height were discomfort factors. In the evaluation of motion suitability, dissatisfaction was found with the sleeve circumference, elbow circumference, armhole circumference, knee crease and crotch height, and back waist height during motion. Therefore, it is necessary to establish a more segmented size system that suits the physique of current female soldiers and to devise appropriate solutions for improving motion suitability. This study is meaningful for its evaluation of the current combat uniform of female soldiers, and it is expected to serve as a reference for the future development of military combat uniforms for this group.

Development of Reflected Type Photoplethysmorgraph (PPG) Sensor with Motion Artifacts Reduction (생명신호 측정용 반사형 광용적맥파 측정기의 움직임에 의한 신호왜곡 제거)

  • Han, Hyo-Nyoung;Lee, Yun-Joo;Kim, Jung-Sik;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • One of the most important issues in the wearable healthcare sensors is to minimize the motion artifacts in the vital signals for continuous monitoring. This paper presents a reflected type photoplethysmograph (PPG) sensor for monitoring heart rates at the artery of the wrist. Active noise cancellation algorithm was applied to compensate the distorted signals by motions with Least Mean Square (LMS) adaptive filter algorithms, using acceleration signals from a MEMS accelerometer. Experiments with a watch type PPG sensor were performed to validate the proposed algorithm during typical daily motions such as walking and running. The developed sensor is suitable for ubiquitous healthcare system and monitoring vital arterial signals during surgery.

An Introduction of Myo Armband and Its Comparison with Motion Capture Systems

  • Cho, Junghun;Lee, Jang Hyung;Kim, Kwang Gi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • Recently, ways for accurately measuring the three dimensional movements of hand are actively researched so as to utilize the measurement data for therapeutic and rehabilitation programs. This research paper aims to introduce a product called Myo Armband, a wearable device comprised of a 3-axis accelerometer, a 3 axis gyroscope, and electromyographic sensors. We compare Armband's performance with that of the Motion Capture System, which is known as a device for providing fairly accurate measurements for angular movements of objects. Dart throwing and wrist winding motions comprised movement scenarios. This paper also discusses one of Armband's advantages - portability, and suggests its potential as a substitute for previously used devices. Decent levels of measurement accuracy were obtained which were comparable to that of three dimensional measurement device.

Electromyography Triggered Training System for Wrist Rehabilitation (근전도 트리거 손목 재활 훈련 시스템 개발)

  • Kim, Younghoon;Le, DuyKhoa;Chee, Youngjoon;Ahn, Kyoungkwan;Hwang, Changho
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.148-155
    • /
    • 2013
  • This study is about the development of the wrist rehabilitation system for the patient who has limited capability of movement after stroke. Electromyography triggered training system (ETTS) can play the role between complete passive training and patient activating training system. Surface EMG was measured on pronator teres muscle and biceps brachii muscle for wrist pronation and supination. Our system detects whether the subject makes muscular effort for pronation or supination or nothing in every 50 ms. When the effort level exceeds the preset percentage of maximal voluntary contraction, the motor rotates according to the direction of the intention of the subject. EMG triggers the motor rotation for the wrist rehabilitation training until the preset angle. To evaluate its performance, the maximum voluntary contraction level was measured for 4 subjects at first. With the audio-visual instruction to rotate the wrist (pronation or supination) the subjects made effort to follow the instruction. After calculating root mean square (RMS) for 50 ms, the controller determines whether there was muscular effort to rotate while holding the motor. When there was an effort to rotate, the controller rotates the motor 0.8 degree. By comparing the RMS values from two channels of EMG, the controller determines the rotational direction. The onset delay is $0.76{\pm}0.24$ s and offset delay is $0.65{\pm}0.22$ s for pronation. For supination the onset delay is $1.24{\pm}0.41$ s and offset delay is $0.77{\pm}0.22$ s. The system responded fast enough to be used for rehabilitation training. The controller perceived the direction of rotation 100% correctly for the pronation and 97.5% correctly for supination. ETTS was developed and the fundamental functions were validated for normal subjects. The clinical validation should be done with patients for real world application. With ETTS, the subjects can train voluntarily over the limitation of the range of motion which increases the effectiveness of the rehabilitation training.

Kinetic Analysis of Human Simulation for the Soft Golf Swing (소프트 골프 스윙 동작을 위한 인체 시뮬레이션의 운동역학 분석)

  • Kwak, K.Y.;Yu, M.;So, H.J.;Kim, S.H.;Kim, N.G.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.141-150
    • /
    • 2010
  • The purpose of this study was to analyze the golf swing motion for a soft golf clubs and regular golf club. Soft golf is a newly developed recreational sports for all ages, including the elderly and the beginners of golf. To quantify the effect of using soft golf club, which much lighter club than regular clubs, a motion analysis has been performed using a 3D optoelectric motion tracking system that utilizes active infrared LEDs and near-infrared sensors. The subject performed swing motion using a regular golf club and a soft golf club in turn. The obtained motion capture data was used to build a 3D computer simulation model to obtain left wrist, elbow shoulder and lumbar joint force and torque using inverse and forward dynamics calculations. The joint force and torque during soft golf swing were lower than regular golf swing. The analysis gave better understanding of the effectiveness of the soft golf club.

Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery (최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상)

  • Park, Hyeonjun;Won, Jongseok;Park, Jaeheung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

The Motion Analysis of the Scaphoid, Capitate and Lunate During Dart-Throwing Motion Using 3D Images (3차원 영상을 이용한 다트 던지기 운동에서의 주상골, 유두골, 월상골의 움직임 분석)

  • Park, Chan-Soo;Kim, Kwang-Gi;Kim, Yu-Shin;Jeong, Chang-Bu;Jang, Ik-Gyu;Lee, Sang-Lim;Oh, Su-Chan;Yu, Do-Hyun;Baek, Goo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.144-150
    • /
    • 2011
  • The primary purpose of this study was to analyze the motion of the scaphoid, capitate, and lunate during dart-throwing motion by three-dimensional modeling. Five series of CT images of five normal right wrists were acquired from five motion steps from radial extension to ulnar flexion in the dart-throwing motion plane. Segmentation and three-dimensional modeling of bones from CT images was performed using Analyze. Distances among centroids of the scaphoid, capitate and lunate and angles between principal axes of three carpal bones were calculated to analyze the motion by using MATLAB. As the wrist motion changed from radial extension to ulnar flexion, the distance between two adjacent bones decreased. The scaphoid and lunate rotated less than the capitates during dart-throwing motion. This study reports the Three-dimensional in vivo measurement of carpal motion using CT images.

Application of Multiple Fuzzy-Neuro Controllers of an Exoskeletal Robot for Human Elbow Motion Support

  • Kiguchi, Kazuo;Kariya, Shingo;Wantanabe, Keigo;Fukude, Toshio
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • A decrease in the birthrate and aging are progressing in Japan and several countries. In that society, it is important that physically weak persons such as elderly persons are able to take care of themselves. We have been developing exoskeletal robots for human (especially for physically weak persons) motion support. In this study, the controller controls the angular position and impedance of the exoskeltal robot system using multiple fuzzy-neuro controllers based on biological signals that reflect the human subject's intention. Skin surface electromyogram (EMG) signals and the generated wrist force by the human subject during the elbow motion have been used as input information of the controller. Since the activation level of working muscles tends to vary in accordance with the flexion angle of elbow, multiple fuzzy-neuro controllers are applied in the proposed method. The multiple fuzzy-neuro controllers are moderately switched in accordance with the elbow flexion angle. Because of the adaptation ability of the fuzzy-neuro controllers, the exoskeletal robot is flexible enough to deal with biological signal such as EMG. The experimental results show the effectiveness of the proposed controller.

The Biomechanical Analysis of Throwing Motion for the Elementary Students - Developmental Approach - (초등학교 학생들의 발달단계에 따른 던지기 동작의 운동역학적 분석)

  • Lee, Dong-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.69-79
    • /
    • 2007
  • The purpose of this study was to examine the characteristics of throwing motion in the elementary school students from the developmental point of view. For the purpose of this, total of nine subjects(each of three students in five, third, and first grades) were participated. They were asked to throw the ball as far as they can and the motions were videotaped with the 30frames/sec and 1/500 shutter speed. The successful motions for each subject were selected for three dimensional analysis. The collected data were analyzed using DV express 1.0 and Kwon3D 3.0 softwares. The results obtained from this study were as follows; 1. Total time for the throwing motion of the first grade was longer than that of the fifth and third grades. 2. The resultant displacement and velocity of COM for the fifth and third grades were greater than that of the frist grade. 3. The first grade tended to flex the trunk forward excessively during the throwing motion. 4. The fifth grade tended to place the upper arm close to the sagital plane and move the forearm and hand freely. 5. Looking at the greater variability of the angular velocity of the hand segment, the fifth grade seemed to have faster and more flexible movement of the wrist. 6. There were somewhat differences in the patterns and magnitudes of ground reaction forces among the different grades.