• 제목/요약/키워드: Working temperature

검색결과 1,488건 처리시간 0.023초

평판형 히트파이프식 핫척의 표면온도 균일화 향상을 위한 연구 (Study on Improvement of Surface Temperature Uniformily in Flate-Plate Heat Pipe Hot Chuck)

  • 김대현;이석호;임택규;이충구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2369-2374
    • /
    • 2008
  • In the precision hot plate for wafer processing, the temperature uniformity of upper plate surface is one of the key factors affecting the quality of wafers. Precision hot plates require temperature variations less than ${\pm}1.5%$ during heating to $120^{\circ}C$. In this study, we have manufactured the flat plate heat pipe hot chuck of circle type(300mm) and investigated the operating characteristics of flat plate heat pipe hot chuck experimentally. Various liquids(aceton, FC-40, water) were used as the working fluid and charging ratio was changed($14{\sim}36\;vol.%$). Several cases were tested to improve temperature uniformity. Major working fluid to be investigated was water. Using water, various parameters such as charging ratio, wafer operation on-off time, different working fluids. In case of water, the temperature uniformity was ${\pm}1.5%$, response time of wafer were investigated.

  • PDF

미립잠열슬러리의 유체역학적 특성연구 (Fluid dynamical characteristics of microencapsulated phase change material slurries)

  • 이효진;이승우;이재구
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

중온 태양열 축열조용 히트파이프의 작동액체 충전량이 열성능에 미치는 영향 (The Effect of Working Fluid Charge on the Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System)

  • 박민규;부준홍
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.68-73
    • /
    • 2011
  • An experimental study was conducted to investigate the thermal performance of a medium-temperature heat pipe against the charge amount of working fluid. The container and the wick of the heat pipe were made of stainless steel and the working fluid was Dowtherm-A for medium-temperature applications around $250^{\circ}C$. The diameter and length of the heat pipe were 25.4 mm and 1 m, respectively. The maximum thermal load was 1 kW and the working fluid charge ratio varied from 372% to 420%. The results showed that the thermal resistance ranged from 0.12 to $250^{\circ}C/W$ and the effective thermal conductance ranged from 7,703 to $8,898 W/m{\cdot}K$. Dry-out occurred for the heat pipe with 372% fill-charge at the heat load of 950 W, while the other heat pipes with higher charge amount did not encounter dry-out up to 1060 W.

  • PDF

굳지 않은 MMA개질 UP 폴리머 콘크리트의 사용가능시간에 미치는 온도와 결합재의 영향 (Effects of Temperature and Binder Components on Working Life of Fresh MMA Modified UP Polymer Concrete)

  • 연정흠;현상훈
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.51-61
    • /
    • 2012
  • PURPOSES : This study deals with the working life of polymer concrete, which is typically used as a repair or overlay material for portland cement concrete pavements. METHODS : In the scope of this study, laboratory testing was conducted on fresh MMA modified UP polymer concrete, which uses an MMA monomer for viscosity adjustment and strength improvement of UP resin. The experimental variables were temperature (-20 to $+20^{\circ}C$) and binder components (MMA, MEKPO, and DMA). RESULTS : The result showed that the optimum binder ratios for polymer concrete production were 12, 11, and 10 wt.% when the MMA contents were 20, 30, and 40 wt.%, respectively. The working life of polymer concrete depending on temperature and binder components could be expressed by a logarithmic functional formula. The coefficient of variation for each binder component was the highest for DMA content while the lowest for MEKPO content. Also, the contents of each binder component for ensuring the working life of 60 minutes were proposed. CONCLUSIONS : Ultimately, the present study derived a linear regression equation estimating 60 minutes working life based on the setting times of each binder component.

모세구동 소형 냉각시스템의 실험적 연구 (An Experimental Study on Small Capillary Pumped Cooling System)

  • 양재경;이규정;이정현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.234-239
    • /
    • 2000
  • The capillary pumped cooling system (CPCS) is a cooling system which controls temperature of the small electronic devices, such as IC device systems, notebook computers, etc. An important feature of CPCS is that a working fluid circulates in a system by capillary force in tubes instead of mechanical input power. The cooling effect of CPCS is investigated with respect to heat flux, condensation temperature under different working fluids (water, ethanol, methanol). Capillary pumped flows are visualized under various conditions and mass flow rate and temperature are experimentally measured. It is shown that the increasing tendency of mass flux for each working fluid is observed as the temperature of evaporator increases, and that the cooling possibility of CPCS depends on the performance of evaparator and condenser which sustains the steady state temperature continuously.

  • PDF

감마형 자유피스톤 스털링 엔진의 작동주파수 분석 (Analyses on Working Frequency of A γ-type Free-piston Stirling Engine)

  • 장선준;심규호;이윤표
    • 한국소음진동공학회논문집
    • /
    • 제23권7호
    • /
    • pp.654-661
    • /
    • 2013
  • The dynamic characteristics of a free-piston stirling engine(FPSE) with regard to the working frequency is investigated from theoretical and experimental studies. The FPSE is modeled as a two degree-of-freedom linear vibration system. A theoretical expression on the working frequency is derived from the instability condition for self-excitation based on the linear vibration model. A ${\gamma}$-type free-piston stirling engine is fabricated for experimental studies, and its working frequency is measured on various heater temperatures. Comparisons between the theoretical and experimental results reveal that the working frequency of the test FPSE depends on both the temperature of the compression space and the temperature difference between the expansion and compression spaces.

중온 히트파이프에서 작동유체 선정에 관한 실험적 연구 (Experimental Study on the Working Fluid Selection of Medium Temperature Heat Pipe)

  • 이영수;박기호;백영진
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.1-7
    • /
    • 2007
  • This paper is concerned with the selection of proper working fluids for medium temperature range heat pipe. The heat pipe which is made of SUS 316L has a total length of 700 mm as well as an outside diameter of 27.2 mm and a thickness of 2.1 mm respectively. Working fluids used in this study were Naphthalene, Biphenyl and Dowtherm A. Their charge amounts were about 40% of the inside volume of evaporator section. Experimental results shows that the Dowtherm A is good for $200^{\circ}C{\sim}300^{\circ}C$temperature range, while the Naphthalene is proper for $300^{\circ}C{\sim}430^{\circ}C$. In the case of the Naphthalene heat pipe, the heat transfer rate reaches 1500 W along with a vapor temperature of $430^{\circ}C$.

  • PDF

열원온도와 작동유체에 따른 초월임계 유기랭킨사이클의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Transcritical Organic Rankine Cycle Depending on Source Temperature and Working Fluid)

  • 김경훈
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.699-707
    • /
    • 2017
  • 본 연구에서는 아홉 종류의 작동유체를 고려하여 저온 열원으로 구동되는 아임계 및 초월임계 유기 랭킨 사이클의 열역학적 성능 특성을 비교 해석한다. 터빈입구압력, 열원온도 및 작동유체가 열교환기 내 온도분포와 핀치포인트, 작동유체의 유량, 시스템 출력 및 열효율 등 시스템의 성능에 미치는 영향을 분석한다. 해석 결과는 작동유체의 압력이 아임계 영역에서 초임계 영역으로 높아지면 열교환기에서 열원과 작동유체 사이의 온도 불균일 정도가 감소하면서 시스템 출력이나 열효율 등은 증가하나 시스템의 단위출력당 터빈 크기는 작아짐을 보여준다.

작동유체에 따른 유기랭킨사이클(ORC)의 열역학적 성능에 관한 연구 (Study of Working Fluids on Thermodynamic Performance of Organic Rankine Cycle (ORC))

  • 김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제22권2호
    • /
    • pp.223-231
    • /
    • 2011
  • The thermal efficiency of energy-to-power conversion becomes uneconomically low when the temperature of heat source drops below $370^{\circ}C$. ORC (Organic Rankine Cycle) has attracted much attention in last few years due to its potential in reducing consumption of fossil fuels and relaxing environmental problems, and its favorable characteristics to exploit low-temperature heat sources. In this work thermodynamic performance of ORC using nine working fluids is comparatively assessed. Special attention is paid to the effect of system parameters such as turbine inlet temperature and pressure on the characteristics of the system such as volumetric flow rate and quality at turbine exit, latent heat, net work as well as thermal efficiency. Results show that in selection of working fluid it is required to consider various criteria of performance characteristics as well as the thermal efficiency. Results also show that the system efficiencies become same irrespective of kind of working fluid when the temperature of heat source decreases to low range.

흰쥐의 적출된 심장에서 심정지액의 온도가 심근보호에 미치는 영향 (The Effect of Temperature of Cardioplegic Soultion on Myocardial Protection from Ischemia - Experimental Study using Isolated Rat Heart Perfusion Technique -)

  • 김용한
    • Journal of Chest Surgery
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 1992
  • The effect of temperature of cardioplegic solution on myocardial preservation was studied using isolated rat heart perfusion technique. Twenty Sprague-Dawley rats, weighing 120~140gm, were pretreated with intraperitoneal injection of heparin sodium[300u/kg] and then the hearts were excised after cervical herniation 30 minutes later. The hearts were perfused in isolated working heart apparatus with oxygenated modified Tyrode solution at 37oC. After 10 minutes of non working heart perfusion, the hearts were subjected to arrest for 30 minutes by administration of 5cc cardioplegic solution at the temperature of 4oC [Group I ], 15oC [Group II], 25oC [Group III], 37oC[Group IV]. At the same time, the topical cooling of heart was performed using ice saline. After arrest, the hearts were reperfused by non working heart perfusion for 1 hour with modified Tyrode solution at 37oC. The CPK, GOT and LDH in reperfusate were measured at 5,20,40,60 minutes after start of reperfusion. With the values of those, we compared the effect of temperature of cardioplegic solution on myocardial preservation. The results were as follows; 1. The enzyme values in reperfusate were highest at 5 minute and after then declined. 2. At 5 minutes after reperfusion, the enzyme values in Group I were lower than those in other Groups. These results suggest that the cardioplegic solutions using for cardiac arrest and myocardial protection can be working better at 4oC than at any other temperature.

  • PDF