• 제목/요약/키워드: Working Gas

검색결과 708건 처리시간 0.034초

Measurements of Remote Micro Displacements of the Piping System and a Real Time Diagnosis on Their Working States Using a PIV and a Neural Network (PIV와 신경망을 이용한 배관시스템 원격 미세변위 측정과 실시간 작동상태 진단)

  • Jeon, Min Gyu;Cho, Gyeong Rae;Oh, Jung Soo;Lee, Chang Je;Doh, Deog Hee
    • Journal of Hydrogen and New Energy
    • /
    • 제24권3호
    • /
    • pp.264-274
    • /
    • 2013
  • Piping systems play an important role in gas and oil transferring system. In the piping system, there are many elements, such as valves and flow meters. In order to check their normal operating conditions, each signal from each element is displayed on the monitor in the pipe control room. By the way, there are several accidental cases in the piping system even if all signals from the local elements are judged to be normal on the monitor in the control room. Further, opposite cases often happen even the monitor shows abnormal while the local elements work normal. To overcome this abnormal functions, it is not so easy to construct the environment in which sensors detecting the working states of all elements installed in the piping system. In this paper, a new non-contact measurement technique which can calculate the elements' delicate displacements by using a PIV(particle image velocimetry) and diagnose their working states by using a neural network is proposed. The measurement system consists of a host computer, a micro system, a telescope and a high-resolution camera. As a preliminary test, the constructed measurement system was applied to measure delicate vibrations of mobile phones. For practical application, a pneumatic system was measured by the constructed system.

Application of Si3N4 Thin Film as a Humidity Protection Layer for Organic Light Emitting Diode (Si3N4 박막의 유기발광소자 수분침투 방지막으로의 응용)

  • Kim, Chang-Jo;Shin, Paik-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제23권5호
    • /
    • pp.397-402
    • /
    • 2010
  • In this paper, we studied WVTR(water vapor transmission rate) properties of $Si_3N_4$ thin film that was deposited using TCP-CVD (transformer coupled plasma chemical vapor deposition) method for the possibility of OLED(organic light emitting diode) encapsulation. Considering the conventional OLED processing temperature limit of below $80^{\circ}C$, the $Si_3N_4$ thin films were deposited at room temperature. The $Si_3N_4$ thin films were prepared with the process conditions: $SiH_4$ and $N_2$, as reactive gases; working pressure below 15 mTorr; RF power for TCP below 500 W. Through MOCON test for WVTR, we analyzed water vapor permeation per day. We obtained that WVTR property below 6~0.05 gm/$m^2$/day at process conditions. The best preparation condition for $Si_3N_4$ thin film to get the best WVTR property of 0.05 gm/$m^2$/day were $SiH_4:N_2$ gas flow rate of 10:200 sccm, working pressure of 10 mTorr, working distance of 70 mm, TCP power of 500 W and film thickness of 200 nm. respectively. The proposed results indicates that the $Si_3N_4$ thin film could replace metal or glass as encapsulation for flexible OLED.

A Study on 1-Butene Oxidation over Vanadium Oxide Electrode (바나듐산화물 전극상에서 1-부텐의 산화반응 연구)

  • Park, Seungdoo;Lee, Hag-Young;Hong, Suk-In
    • Applied Chemistry for Engineering
    • /
    • 제9권4호
    • /
    • pp.523-528
    • /
    • 1998
  • The electrochemical characteristics of $V_2O_5$ as working electrode were studied in the cell (1-butene+$O_2$, $V_2O_5{\mid}YSZ{\mid}Ag$, $O_2$) with a YSZ solid electrolyte. The sintering of Ag as a counter electrode was occurred after calcination, and the structure which has the pores of over $3{\mu}m$ was achieved. In particular, the peak of (010) plane of the working electrode on the XRD spectrum which is responsible for selective oxidation appeared after calcination. The major product of 1-butene oxidation over $V_2O_5$ was butadiene. The technique of SEP (solid electrolyte potentiometry) was used to monitor the chemical potential of chemical species adsorbed on the working electrode. Over a wide range of gas compositions of 1-butene and oxygen, open circuit voltage (OCV) exhibited the mixed potential of surface oxygen activity.

  • PDF

Performance Analysis of Absorbent for Post-combustion CO2 Capture by Regeneration (연소 후 CO2 포집을 위한 흡수제의 재생반응에 의한 성능 해석)

  • KIL, TAEHYOUNG;LEE, DONGHO;JO, SUNGHO;YI, CHANGKEUN;PARK, YEONGSEONG;RYU, HOJUNG
    • Journal of Hydrogen and New Energy
    • /
    • 제27권1호
    • /
    • pp.83-94
    • /
    • 2016
  • Performance of absorbent for post-combustion $CO_2$ capture was measured and discussed. Fully saturated fresh absorbent (P2-15F) and absorbents sampled from absorption and regeneration reactor of continuous $CO_2$ capture process, P2-15A, P2-15R, respectively, were used as representative absorbents. Small scale fluidized bed reactor (0.05 m I.D., 0.8 m high) which can measure exhaust gas concentration and weight change simultaneously was used to analyze regeneration characteristics for those absorbents. Exhausted moles of $CO_2$ and $H_2O$ were measured with increasing temperature. $H_2O/CO$ ratio and working capacity were determined and discussed to confirm reason of reactivity decay after continuous operation. Moreover, possibility of side reaction was checked based on the $H_2O/CO_2$ mole ratio. Finally, suitable regeneration temperature range was confirmed based on the trend of working capacity with temperature.

Influence of NCG Charging Mass on the Heat Transport Capacity of Variable Conductance Heat Pipe (불응축가스량이 가변전열 히트파이프의 열수송 특성에 미치는 영향)

  • Suh Jeong-Se;Park Young-Sik;Chung Kyung-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제18권4호
    • /
    • pp.320-327
    • /
    • 2006
  • Numerical analysis and experimental study are performed to investigate the effect of heat load and operating temperature on the thermal performance of several variable conductance heat pipe (VCHP) with screen meshed wick. The heat pipe is designed in 200 screen meshes, 500 mm length and 12.7 mm outer diameter tube of copper, water (4.8 g) is used as working fluid and nitrogen as non-condensible gas (NCG). Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Analysis values and experimental data of wall temperature distribution along axial length are presented for heat transport capacity, condenser cooling water temperature change, degrees of an inclination angle and operating temperature. These analysis and experiment give the follow findings: For the same charging mass of working fluid, the operating temperature of heat pipe becomes to be high with the increasing of charging mass of NCG. When the heat flux at the evaporator section increases, the vapor pressure in the pipe rises and consequently compresses the NCG to the condenser end part and increases the active length of the condenser. From previous process, it is found out we can control the operating temperature effectively and also the analysis and experimental results are relatively coincided well.

A Study on the Refrigerant Characteristics of the Organic Rankine Cycle Power System Using the Waste Heat of the Main Propulsion Engine (선박 주 추진 엔진폐열을 이용하는 고온도차발전시스템의 냉매특성에 관한 연구)

  • Song, Young-uk;Jee, Jae-hoon;Park, Sang-kyun;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제27권6호
    • /
    • pp.839-845
    • /
    • 2021
  • In this study, it shows the efficiency of each refrigerant through simulation method for ORC (Organic Rankine Cycle) power generation that converts waste heat discarded by ship exhaust into electricity for the purpose of reducing CO2 emission and increasing ship waste heat recovery. by Simulation was performed with waste heat from the exhaust gas which is relatively high temperature and cooling sea water which is relatively low temperature from ships. As a result of the sea water cooling ORC power generating system, efficiency of the working fluid with R717 is highest as a 2.86 % and the next working fluid is R152a, R134a, R143a and R125a.

Investigation of the Bonding Stress of the 2nd Barrier for LNG Carrier Cargo Containment System Considering Various Working Conditions (다양한 작업 조건을 고려한 LNG 운반선 화물창 2차 방벽의 극저온 접착강도 분석)

  • Jeong-Hyeon Kim;Hee-Tae Kim;Byeong-Kwan Hwang;Seul-Kee Kim;Tae-Wook Kim;Doo-Hwan Park;Jae-Myung Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제26권3호
    • /
    • pp.499-507
    • /
    • 2023
  • The core of the liquefied natural gas (LNG) carrier cargo containment system (CCS) is to store and transport LNG safely under temperatures below -163 degrees Celsius. The secondary barrier of the LNG CCS is adopted to prevent LNG leakage from CCS to the ship's hull structure. Recently, as the size of the LNG CCS increases, various studies have been conducted on the applied temperature and load ranges. The present study investigates the working condition-dependent bonding strength of the PU15 adhesives of the secondary barrier. In addition, the mechanical performance is analyzed at a cryogenic temperature of -170 degrees Celsius, and the failure surface and failure mode are investigated depending on the working condition of the bonded process. Even though the RSB and FSB-based fracture mode was confirmed, the results showed that all the tested scenarios satisfied the minimum requirement of the regulation.

Performance Analysis of a 3 Pressured Combined Cycle Power Plant (3압 복합 발전 플랜트 사이클에 대한 성능해석)

  • Kim, S. Y.;K. S. Oh;Park, B. C.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제2권2호
    • /
    • pp.74-82
    • /
    • 1998
  • Combined cycle power plant is a system where a gas turbine or a steam turbine is used to produce shaft power to drive a generator for producing electrical power and the steam from the HRSG is expanded in a steam turbine for additional shaft power. The temperature of the exhaust gases from a gas turbine ranges from $400{\sim}650^{\circ}C$, and can be used effectively in a heat recovery steam generator to produce steam. Combined cycle can be classed as a topping and bottoming cycle. The first cycle, to which most of the heat is supplied, is a Brayton gas turbine cycle. The wasted heat it produces is then utilized in a second process which operates at a lower temperature level is a steam turbine cycle. The combined gas and steam turbine power plant have been widely accepted because, first, each separate system has already proven themselves in power plants as an independent cycle, therefore, the development costs are low. Secondly, using the air as a working medium, the operation is relatively non- problematic and inexpensive and can be used in gas turbines at an elevated temperature level over $1000^{\circ}C$. The steam process uses water, which is likewise inexpensive and widely available, but better suited for the medium and low temperature ranges. It therefore, is quite reasonable to use the steam process for the bottoming cycle. Recently gas turbine attained inlet temperature that make it possible to design a highly efficient combined cycle. In the present study, performance analysis of a 3 pressured combined cycle power plant is carried out to investigate the influence of topping cycle to combined cycle performance. Present calculation is compared with acceptance performance test data from SeoInchon combined cycle power plant. Present results is expected to shed some light to design and manufacture 150~200MW class heavy duty gas turbine whose conceptual design is already being undertaken.

  • PDF

A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier (LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구)

  • Park, Gi-Beom;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.345-352
    • /
    • 2017
  • In this study, the effect of cryogenic liquefied natural gas leakage and loading on liquefied natural gas cargo hold is investigated to observe the performance of the polymer foam material that comprises the cryogenic insulation of the cargo hold. The primary barriers of liquefied natural gas carrier that are in contact with the liquefied natural gas will leak if damage is accumulated, owing to fluid impact loads or liquefied natural gas loading / unloading over a long period. The leakage of the cryogenic fluid affects the interior of the polymer foam, which is a porous closed cell structure, and causes a change in behavior with respect to the working load. In this study, mechanical properties of polyisocyanurate foam specimen, which is a polymer material used as insulation, are evaluated. The performance of the specimens, owing to the cold brittleness and the impregnation effects of the cryogenic fluids, are quantitatively compared and analyzed.

A Valuation for Gas Hydrate R&D Project Using Fuzzy Real Options Model (퍼지실물옵션모형을 이용한 가스하이드레이트 R&D 사업의 가치평가)

  • Yun, Ga-Hye;Heo, Eunnyeong
    • Environmental and Resource Economics Review
    • /
    • 제18권2호
    • /
    • pp.217-239
    • /
    • 2009
  • As gas hydrate is recently emerging as a new energy source to solve environmental and exhaustion problems caused by fossil energy, Korea is working on a gas hydrate development project under a 10-year plan from 2005 to 2014. Gas hydrate is expected to have a big effect on the economy and society of Korea, which is largely depending on energy imports besides water energy and atomic energy. However, it is uncertain whether the project will produce successful results. Thus, it is very important to improve its validity and to propose effective execution strategies by evaluating the value of the project in advance. Thus, this study intended to include new information, which had not been evaluated in existing methods, and to reduce biases or errors in value evaluation results by applying a fuzzy risk analysis to the real option model in order to evaluate the value of a gas hydrate development project. It is advantageous that the real option model based on the fuzzy risk analysis modelizes the vagueness and inexactness of intangible element judgment into an appropriate language scale so as to evaluate these elements clearly and integrate them with estimated financial performance results. The application of the fuzzy risk analysis makes it possible to conduct an analysis by dissolving a decision-making issue with complicated and various attributes into several simplified problems. With the continuing high oil prices and today's demand of clean energy, the necessity of energy resources and technology development projects keeps growing. Amid this situation, it is expected that these study results will contribute to proposing a guideline not only for gas hydrate projects but also for policy decision-making related to future energy industries.

  • PDF