A Study on the Factors of Absenteeism among the Manufacturing Workers (제조업 근로자들의 결근요인 분석)

  • Lee, Dong-Bae;Lee, Tae-Yong;Cho, Young-Chae;Lee, Young-Soo;Oh, Jang-Kyun;Park, Am
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.4 s.44
    • /
    • pp.574-586
    • /
    • 1993
  • This study was to examine the actual conditions and contributing factors of absenteeism in manufacturing workers. Subjects were 1,184 workers employed in Taejon city and the observation period for absenteeism was 3 months (June to August), 1992. We obtained the following results. 1. Percentage of the absentees among the studied subjects were 21.1% in gross absence and 6.9% in sickness absence. Gross absence rate of subjects was 1.2% and sickness absence rate was 0.5%. 2. In the group of absentees, mean days of absence was 2.8 days and those of sickness was 4.4 days. Mean days of sickness absence due to injury was higher than that of illness, but the total days of sickness absence was high in extremity injuries, trunk injury, general fatigue, head injury, musculoskeletal problem in that order. 3. Variables contributing to the absence were job classification, education level, working hours per day, exposure of noxious factor, worker classification. 4. In the group of absentees, variables influencing the gross absence rate were working atmosphere, body mass infer, working environment, working hours per day but those of the sickness absence were working hours per day, education level and working atomosphere.

  • PDF

A Study on the Development of an Automated Pavement Crack Sealer (도로면 크랙 실링 자동화 장비 개발에 관한 연구)

  • Lee Jeong-Ho;Lee Jae-Kwon;Kim Min-Jae;Kim Young-Suk;Cho Moon-Young;Lee Jun-bok
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.539-542
    • /
    • 2002
  • Crack sealing is a maintenance procedure that is commonly used to reduce pavement degradation. If cracks in pavements are not sealed, surface water penetration can reduce the strength of the sub-base layers, which can result in increased deflections of the pavement. Reduced strength of the sub-base also accelerates the deterioration of the surface, due to development of greater cracking and potholes. Crack sealing is performed to reduce water and debris penetration, thereby helping to maintain pavement structural capacity and limiting future degradation. The process of sealing cracks in pavements is however dangerous, costly, and labor-intensive operation. Labor turnover and training are increasing problems related to crack sealing crews, and as traffic volumes increase. Automating crack sealing can reduce labor and road user costs, improve work quality, and decrease worker exposure to roadway hazards. The main objective of this research is to develop an automated system for sealing cracks in pavement. Extension of the algorithms and tools presented in this research is also recommended for future study.

  • PDF

The effect of smoking and drinking habit on the health status of lead workers (흡연과 음주가 연취급 근로자들의 건강수준에 미치는 영향)

  • Lee, Choong-Koo;Kim, Yong-Bae;Lee, Gap-Soo;Hwang, Kyu-Yoon;Kim, Hwa-Sung;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.708-718
    • /
    • 1998
  • To investigate the effect of smoking and drinking habit on the health status in lead using industries, 2,785 male workers in lead using industries (7 storage battery industries, 7 secondary smelting and related industries, and 4 primary metal and other manufacturing industries) were selected for this study. This study was carried out as a part of periodic health examination. Selected study variables were zinc protoporphyrin in whole blood (ZPP), SGOT and SGPT for laboratory test. Questionnaire for lead related symptoms and smoking and drinking habit was provided to all the workers and filled up by themselves and reconfirmed by physician. The results obtained were as follows; 1. The overall smoking and drinking rate of study population were 69.8% and 73.6%, respectively. While the smoking and drinking rate of storage battery workers were 68.8% and 72.3%, those of secondary smelting industries and other industries were 66.0% & 66.4% and 74.6 & 80.3% respectively. 2. While the mean values of blood ZPP of lead exposed workers were significantly higher than other group, those of SGOT of storage battery workers were significant higher than other worker. But there were no differences of mean values of other variables. 3. Smoking habit did not affect on the mean value of blood ZPP of workers in special health examination group, but there were significant differences of blood ZPP and SGOT between drinker and non-drinker. 4. Symptom prevalence of lead exposure were higher in drinking and smoking group than non-drinking and non-smoking group. 5. In multiple regression analysis of the total lead related symptoms, blood ZPP, SGOT, and SGPT as dependent variable, respectively, and age, work duration, blood ZPP, pack year and amount of alcohol drinking as independent variables, work duration, pack year, amount of alcohol drinking, age contributed to total symptoms; and age, work duration, pack year contributed to blood ZPP; and age, amount of alcohol drinking, work duration contributed to SGOT; and pack year contributed to SGPT.

  • PDF

Flow Characteristics Evaluation in Reactor Coolant System for Full System Decontamination of Kori-1 Nuclear Power Plant (고리1호기 계통제염을 위한 원자로냉각재내 유동 특성 평가)

  • Kim, Hak Soo;Kim, Cho-Rong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.389-396
    • /
    • 2018
  • The Kori-1 Nuclear Power Plant (NPP), WH 2-Loop Pressurized Water Reactor (PWR) operated for approximately 40 years in Korea, was permanently ceased on June 18, 2017. To reduce worker exposure to radiation by reducing the dose rate in the system before starting main decommissioning activities, the permanently ceased Kori-1 NPP will be subjected to full system decontamination. Generally, the range of system decontamination includes Reactor Pressure Vessels (RPV), Pressurizer (PZR), Steam Generators (SG), Chemical & Volume Control System (CVCS), Residual Heat Removal System (RHRS), and Reactor Coolant System (RCS) piping. In order to decontaminate these systems and equipment in an effective manner, it is necessary to evaluate the influence of the flow characteristics in the RCS during the decontamination period. There are various methods of providing circulating flow rate to the system decontamination. In this paper, the flow characteristics in Kori-1 NPP reactor coolant according to RHR pump operation were evaluated. The evaluation results showed that system decontamination using an RHR pump was not effective at decontamination due first to impurities deposited in piping and equipment, and second to the extreme flow unbalance in the RCS caused deposition of impurities.

Factors Influencing the Communication Skill for the Elderly of Dental Hygienist (치과위생사의 노인에 대한 의사소통능력에 영향을 미치는 요인)

  • Lim, Hee-Jung;Kim, Hyoung-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.6
    • /
    • pp.627-635
    • /
    • 2016
  • The purpose of this study was to investigate the communication skill of a dental hygienist for the elderly. The self-administered questionnaire selected by convenience sampling method from January 2 to February 14, 2015, Seoul, Kyungki, Incheon regions final analysis section 233 to target dental hygienist working under a dentist institutions. This study analyzed collected data by t-test, ANOVA, pearson correlation coefficient, and multiple regression. According to multiple regression analysis results can be number of worker, the main task, living experience feelings adjusted variable, as a result work in the dental hospital(B=.292 SE=.074), more like the elderly preference(B=.282, SE=.141), the behavior of the elderly(B=-.223, SE=.043) found that the more positive the impact. Therefore, the more exposure for your understanding and the elderly relationships for the the elderly appeared to affect the communication skill necessary to develop training programs that can improve the communication skill of a dental hygienist and apply to be prepared for the coming aging society.

Implementation of Constructor-Oriented Visualization System for Occluded Construction via Mobile Augmented-Reality (모바일 증강현실을 이용한 작업자 중심의 폐색된 건축물 시각화 시스템 개발)

  • Kim, Tae-Ho;Kim, Kyung-Ho;Han, Yunsang;Lee, Seok-Han;Choi, Jong-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.55-68
    • /
    • 2014
  • Some infrastructure these days is usually constructed under the ground for it to not interfere the foot-traffic of pedestrians, and thus, it is difficult to visually confirm the accurate location of the site where the establishments must be buried. These technical difficulties increase the magnitude of the problems that could arise from over-reliance on the experience of the worker or a mere blueprint. Such problems include exposure to flood and collapse. This paper proposes a constructor-oriented visualization system via mobile gadgets in general construction sites with occluded structures. This proposal is consisted with three stages. First, "Stage of detecting manhole and extracting features" detects and extracts the basis point of occluded structures which is unoccluded manhole. Next, "Stage of tracking features" tracks down the extracted features in the previous stage. Lastly, "Stage of visualizing occluded constructions" analyzes and synthesizes the GPS data and 3D objects obtained from mobile gadgets in the previous stages. This proposal implemented ideal method through parallel analysis of manhole detection, feature extraction, and tracking techniques in indoor environment, and confirmed the possibility through occluded water-pipe augmentation in real environment. Also, it offers a practical constructor-oriented environment derived from the augmented 3D results of occluded water-pipings.

Generation Rate and Content Variation of Manganese in Stainless Steel Welding (스테인레스 강 용접중 발생하는 망간의 발생량 및 함량변화에 관한 연구)

  • Yoon, Chung Sik;Kim, Jeong Han
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.254-263
    • /
    • 2006
  • Manganese has a role as both toxic and essential in humans. Manganese is also an essential component in the welding because it increases the hardness and strength, prevents steel from cracking of welding part and acts as a deoxidizing agent to form a stable weld. In this study, manganese generation rate and its content was determined in flux cored arc welding on stainless steel. Domestic two products and foreign four products of flux cored wires were tested in the well designed fume generation chamber as a function of input power. Welding fume was measured by gravimetric method and metal manganese was determined by inductively coupled plasma-atomic emission spectrophotometer. The outer shell of the flux cored wire tube and inner flux were analyzed by scanning electron microscopy to determine their metal compositions. Manganese generation rate($FGR_{mn}$) was increased as the input power increased. It was 16.3 mg/min at the low input power, 38.1 mg/min at the optimal input power, and up to 55.4 mg/min at the high input power. This means that $FGR_{mn}$ is increased at the work place if welder raise the current and/or voltage for the high productivity. The slope coefficient of $FGR_{mn}$ was smaller than that of the generation rate of total fume(FGR). Also, the correlation coefficient of $FGR_{mn}$ was 0.65 whereas that of FGR is 0.91. $FGR_{mn}$ was equal or higher in the domestic products than that of the foreign products although FGR was similar. From the electron microscopic analytical data, we concluded that outer shell of the wire was composed mainly of iron, chromium, nickel and less than 1.2 % of manganese. There are many metal ingredients such as iron, silica, manganese, zirconium, titanium, nickel, potassium, and aluminum in the inner flux but they were not homogeneous. It was found that both $FGR_{mn}$ and content of manganese was higher and more varied in domestic flux cored wires than those of foreign products. To reduce worker exposure to fumes and hazardous component at the source, further research is needed to develop new welding filler materials that improve the quality of flux cored wire in respect to these points. Welder should keep in mind that the FGR, $FGR_{mn}$ and probably the generation rate of other hazardous metals were increased as the input power increase for the high productivity.

Field Study of Emission Characteristics of Ammonia and Hydrogen Sulfide by Pig Building Types (돈사 작업장 유형에 따른 암모니아와 황화수소의 실내농도 및 발생량에 관한 현장 조사)

  • Kim, Ki Youn;Park, Jae Beom;Kim, Chi-Nyon;Lee, Kyung Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.36-43
    • /
    • 2006
  • The principal aim of this field study was to determine the concentrations and emissions of gaseous contaminants such as ammonia and hydrogen sulfide in the different types of pig buildings in Korea and allow objective comparison between Korea and the other countries in terms of pig housing types. This field study was performed from May to June and from September to October in 2002. Pig buildings investigated in this research were selected in terms of three criteria; manure removal system, ventilation mode and growth stage of pig. Measurements of concentration and emission of ammonia and hydrogen sulfide in the pig buildings were done in 5 housing types and the visited farms were 15 sites per each housing type. Concentrations of ammonia and hydrogen sulfide were measured at three locations of the central alley in the pig building and emission rates of them were estimated by multiplying the average concentration($mg/m^3$) measured near the air outlet by the mean ventilation rate($m^3/h$) and expressed either per pig of liveweight 75kg(mg/h/pig) or per area($mg/h/m^2$). Concentrations of ammonia and hydrogen sulfide in the pig buildings were averaged to 7.5 ppm and 286.5 ppb and ranged from 0.8 to 21.4 ppm and from 45.8 to 1,235 ppb, respectively. The highest concentrations of ammonia and hydrogen sulfide were found in the mechanically ventilated buildings with slats; 12.1 ppm and 612.8 ppb, while the lowest concentrations of ammonia and hydrogen sulfide were found in the pig buildings with deep-litter bed system(2.2 ppm) and the naturally ventilated pig buildings with manure removal system by scraper(115.2 ppb), respectively(p<0.05). All the pig buildings were investigated not to exceed the threshold limit values(TLVs) of ammonia(25 ppm) and hydrogen sulfide(10 ppm). The mean emissions of ammonia and hydrogen sulfide per pig(75kg in terms of liveweight) and area($m^2$) from pig buildings were 250.2 mg/h/pig and 37.8 mg/h/pig and $336.3mg/h/m^2$ and $50.9mg/h/m^2$, respectively. The pig buildings with deep-litter bed system showed the lowest emissions of ammonia and hydrogen sulfide(p<0.05). However, the emissions of ammonia and hydrogen sulfide from the other pig buildings were not significantly different(p>0.05). Concentrations and emissions of ammonia and hydrogen sulfide were relatively higher in the pig buildings managed with deep-pit manure system with slats and mechanical ventilation mode than the different pig housing types. In order to prevent pig farm workers from adverse health effect caused by exposure to ammonia and hydrogen sulfide in pig buildings, they should wear the respirators during shift and be educated sustainably for the guideline related to occupational safety.

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

A Study on Diagnostic Criteria of Noise-Induced Hearing Loss among Workers in an Iron Foundry (철강공장 근로자를 대상으로 살펴본 소음성 난청 진단기준에 관한 조사)

  • Kim, Ji-Yong;Lim, Hyun-Sul;Cheong, Hae-Kwan;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.371-386
    • /
    • 1993
  • This study was carried out to evaluate diagnostic criteria of noise-induced hearing loss (NIHL) among-workers in an iron foundry. Of 1,093 workers under the observation of noise-specific health examination, 184 workers were selected by way of first and second screening audiometric examination. A questionnaire survey, otological examinations, Rinne test and audiometric test were performed and the results were as follows ; The degree of hearing impairment in the left ear was more severe than in the right ear (p<0.05). The difference between hearing threshold of the first and the second hearing test at 1,000 Hz was about 5 dB with a narrow range of deviations while the difference at 4,000 Hz was about -7 dB with a wide range. Of the total study workers, 84.8% were tested within 15 hours away from noise exposure, and the rest after 16 hours. This study has identified that mean hearing loss at 4,000 Hz showed a significant statistical difference among the two study groups while mean hearing loss by 4-divided classification did not. The same phenomena were observed between the group with and without tinnitus and between the group with and without difficulty in hearing (p<0.05). Among 184 workers, 10 workers (5.4%) diagnosed as NIHL by old diagnostic criteria in contrast to 150 workers diagnosed as NIHL by the new diagnostic criteria. There was a significant difference between the two groups in the average hearing loss at 4,000 Hz and 4-divided classification (p<0.01), but there were no significant differences in age, the duration of employment, blood pressure and the duration wearing the personal hearing protector (p>0.05). If we apply Early Loss Index (ELI) method, some workers in younger age group diagnosed as NIHL by the new diagnostic criteria were fallen into within the normal range. In the mean time older age group show reverse results in contrast to the above finding. It is too early to confirm the value of the usage of the new diagnostic criteria in hearing examination. Further study is called for to verify the value of this criteria.

  • PDF