조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가 (Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;윤한수;김석수
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성 (Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;유대훈;이유정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

ZnO 바리스터 소자의 장시간 방전내량 특성 (Long Duration Withstand Current Characteristics of ZnO Varistors)

  • 조한구;윤한수;김석수;한세원;유근양;이용순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.544-545
    • /
    • 2005
  • This paper describes the long duration withstand current characteristics of ZnO varistors. Two ZnO varistors were manufactured with general ceramic production methods and three abroad varistors were also prepared to be compared. During long duration withstand test, sample 1 was destroyed at 4th impulse current but the rest passed test. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test results, it is thought that the manufacturing process such as insulating coating, sintering condition and soldering method should be improved.

  • PDF

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구 (Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring)

  • 최충석
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

170[kV] GIB 내에서 건조공기(Dry Air)의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 170[kV] GIB)

  • 한기선;윤진열;주형준
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.136-142
    • /
    • 2010
  • In this paper, we changed $SF_6$ insulation gases used already in the GIB(Gas Insulated Bus, gas insulated busbar) of switching appliances of power grid 170[kV] GIS(Gas Insulated Switchgear, Gas Insulated Switchgear) with green insulation dry air gases and studied dielectric breakdown voltage characteristics by the AC voltage withstand test. Withstand test AC voltage applied to the standard KEPCO's 170[kV] GIB with dry air insulation and and the equivalent of dry air and $SF_6$ gas were examined. Breakdown voltage of dry air, using an expression of the experiments were calculated and AC Withstand criterion of dry air insulation for the AC voltage test was derived. Using the criterion, dry air gases can be used instead of the $SF_6$ gas was confirmed in the factory acceptance test at 170[kV] GIB.

공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구 (A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit)

  • 한영성;정정주
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.

초고압 SF6 가스 차단기 투입 시 아크접촉자 내전압 특성 연구 (Analysis of Withstand Voltage between Arc Contacts of High Voltage SF6 Gas Circuit Breaker n Making Operation)

  • 김인길;이주현;정형수;박재윤
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.601-605
    • /
    • 2012
  • The non-controlled closing of High-voltage SF6 gas circuit breaker can cause transient current and overvoltage in the field. The controlled closing technology is an effective way to reduce transient current and voltage, prevent equipment failures, and improve power quality. For the development of controlled closing, it is obviously necessary to determine the withstand voltage between arc contacts of High-voltage SF6 gas circuit breaker in making operation. This paper focuses on decrease of pressure and density of SF6 gas that can affect withstand voltage between arc contacts in making operation. The dielectric strength between arc contacts could be improved by minimizing the decrement of pressure and density of SF6 gas obtained by simulation and test and moreover the rate of decrease of dielectric strength (RDDS) of arc contacts could be foreseen.