• Title/Summary/Keyword: With-the-rule astigmatism

Search Result 48, Processing Time 0.027 seconds

Refractive Error Shift in Nuclear, Cortical, and Subcapsular Cataract (핵, 피질 그리고 낭 백내장의 굴절이상 전환)

  • Park, Sang-Chul;Lee, Soek-Ju;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The researchers have studied on the effect of three main morphological types(nuclear, cortical, and subcapsular cataract) of age related cataract on refractive error. We also identified that spherical and cylinderical shift in each type of morphological cataract accoding to their locations and effect of intraocular pressure before and after cataract surgery. Nuclear cataract showed myopic shift while cortical cataract showed hyperopic shift, and subcapsular cataract showed not significant changes on both direction. Age related cataract subjects(120 eyes) only were recruited from sun-cheon area. We use optic section of slit lamp biomicroscope to identify the anatomical location of cataract, and optimal refractive correction determined by objective(retinoscope) and subjective refraction then spherical changes were calculated from the spherical eqivalent value. Intra-ocular pressure were measured by auto-tonometer before and 7 days after cataract has been replaced by IOL. The change in cylindrical power, usually A-P diameter decreased according to increases of age, A-P diameter increased because intra-ocular pressure rises by progression of cataract and this convertion with the rule astigmatism to against the rule astigmatism and this increases more by intra-ocular pressure.

  • PDF

Refractive Error in Middle and High School Pupils (중고등학생의 안굴절 상태조사 및 연구)

  • Pyo, Kyoung-Min;Kim, Woong-Tea
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.119-125
    • /
    • 1996
  • From 1995. 3. 20 to 1995. 4. 10 refractive errors were surveyed on the 1,197 middle and high school pupils in Dong-Du-Cuon area. On the basis of the power of the old glasses or newly examined power, we surveyed the distribution of the refractive errors according to their types, ages, heights, weights and differences between both eyes. Among 2,394 eyes examined, 1,125eyes(47%) were emmetropia, 967 eyes(40.4%) were myopic, and 302eyes(12.6%) were hyperopic. As to the distribution of refractive errors, simple myopia(42.9%) was most common, and mixed astigmatism and compound hyperopic astigmatism were below 1%, Among the types of astigmatism, 62% were with the rule, 23% were against the rule and 15% were oblique, Differences between both eyes, the left eye showed more myopic than those of right eye. The distribution of myopia according to their ages, 27.7 at age 11, 38.5% at age 12, 35.5% at age 41.5% at age 14, 37.7% at age 15, 48.3% at age 16 and 46.8% at age 17., there was a significant increase in the prevalence of the myopia but that or hyperopia decreases with increases of age.

  • PDF

A Correlation between Axis-Rotation and Corneal Eccentricity in Toric Soft Contact Lens Fitting in With-the-rule Astigmatism (직난시안에서의 토릭소프트렌즈 피팅 시 축 회전과 각막이심률과의 상관관계)

  • Park, Hyung Min;Park, Kyounghee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2014
  • Purpose: A correlation between the rotating direction and rotation amount according to the eccentricity was analyzed in the present study when fitting the toric soft contact lens. Methods: One hundred fourteen eyes of with-the-rule astigmatism in 20s and 30s were appropriately applied toric soft contact lens by the guideline of manufacturer and fitting evaluations and analyzed the rotating direction and rotation amount when fixating at primary position and 8 different directions of gaze. The speed of reorientation and the correlation between the rotation amount and cornea eccentricity were also analyzed when rotating $45^{\circ}$ each toward the temporal and nasal direction. Results: The cornea eccentricity and rotation amount was shown positive correlation. For the gaze of direction, it was identified that the gaze of directions other than the gaze of direction towards the nasal and temporal had correlation, and among them, the gaze of directions to superior and the superior-temporal showed the tendency of decreasing rotation amount as the cornea eccentricity increased. On the contrary, the gaze of direction towards the inferior, inferior-temporal, superior-nasal, and inferior-nasal showed tendency of increasing rotation amount as the cornea eccentricity increased thus, it was identified that the cornea eccentricity showed different correlation according to the gaze of direction. For the case of re-orientational speed, the speed of lens reorientation in the group having the smallest corneal eccentricity was fastest in both direction but was not significantly different. Conclusions: Considering cornea eccentricity to current method of prescribing toric soft contact lens which is based on total astigmatism, it will be helpful to establish the optimal axis stabilization.

The Study of Prevalence Rate of Refractive Error among the Primary Students in Jeollanamdo (전남지역 초등학생의 굴절이상 유병률에 관한 연구)

  • Jang, Jung Un;Park, Inn-Jee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.311-318
    • /
    • 2015
  • Purpose: This study was designed to investigate the prevalence rate of refractive error with gender and age presenting visual acuity of primary student in Jeonnam. Methods: Subjective refraction, objective refraction and visual acuity test were examined on 735 primary school children who ages of 8~13 years lived in Jenman. Presenting visual acuity test was using Han's visual acuity chart and objective refraction was carried out using auto-refractometer. Results: The presenting visual acuity was 0.1 worse in the eye of 54(7.3%) students and 49(7.3%) of them wearing the glasses. The rate of the wearing glasses were 79.3% in 0.125~0.25 visual acuity, 64.2% in 0.3~0.5 visual acuity and 61.6% in 0.6~0.8 visual acuity. It was appeared that 269(36.6%) of them were emmetropia, 321(43.7%) of them were myopia and 56(7.6%) of them were hyperopia, and 89(12.1%) of them were astigmatism. The prevalence rate of myopia was the highest and followed by the prevalence rate of astigmatism. The low degree of myopia occupied the most and the medium degree of myopia showed the tendency of increase as the students get olds. The prevalence rate of the hyperopia showed the tendency of decrease as the students get olds. The prevalence rate of with the rule astigmatism were 50.6% students and against the rule astigmatism were 48.3% of students. Conclusions: The present study reveals the considerable prevalence rates, 466(63.4%) of included subjects, of refractive errors among primary students in Jeonnam province. The rate of the wearing glasses were 313(42.6%). The prevalence of myopia increases as the students get older. Therefore students of visual management is considered necessary through the visual acuity test and refractive examination.

A Comparison of Lens Centrations on Cornea with RGP Lens Fitting by the Measured Values using Keratometer and Corneal Topography (각막곡률계와 각막 지형도 검사에서의 측정값을 이용한 RGP 렌즈 피팅시 각막에서의 중심안정위치 비교)

  • Kim, So Ra;Park, Sang-Il;Lee, Se Eun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • Purpose: The present study was conducted to compare the centration of RGP lens on cornea when lens was fitted based on keratometric astigmatisms measured by keratometer and the lens centration when fitted by corneal topography. Methods: Thirty eight eyes of 19 male and female in their twenties were applied RGP lens with 9.9 mm of diameter by the keratometric astigmatisms classified by the measurement with a keratometer. Then, lens centrations were estimated using high speed camera and compared with the lens centration when fitted by total keratometric astigmatism using corneal topography. The relationship of the steepest location of cornea and lens centration was further compared. Results: With the rule astigmatism, lens centration was not changed even with the difference in central and total keratometric astigmatisms. When the relationship of the steepest part of cornea measured by corneal topography and lens centration was analyzed, the lens centration in vertical direction was exactly correlated with the steepest part of cornea in 52.3% of subjects. In the case of non-correlation, the steepest part of cornea was mostly upper part of cornea, however, lens centration was located on lower part of cornea. The lens centration in horizontal direction was exactly correlated with the steepest region of cornea in 65.6% of subjects. In non-correlated case, the difference in cornea curvatures between the steepest and the flattest parts was smaller than 0.05 mm in 76.9% of subjects. Conclusions: From these results, we conclude that corneal topographic patterns may more contribute the centration of RGP lens on cornea than the difference in central and total keratometric astigmatisms.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.