• Title/Summary/Keyword: Wiring Devices

Search Result 71, Processing Time 0.024 seconds

Analysis of Vehicle Fire Accident Caused by Defect of Optionally Established Equipment (부가적으로 설치된 장치 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.40-46
    • /
    • 2014
  • This paper deal with due to the additional equipment established on the vehicle fire accident cases. Recently, vehicle was recognized as other living spaces and it was increasing installation of additional devices such as a black box, multivision, additional battery and so on. However, these additional devices were established on the vehicle by non-specialists such as the general public user or manufacturing and distributors of additional devices since the vehicle factory. Resulting from the additional equipments due to installation errors in these additional equipments connected to the electrical wiring insulation damage or electrical breakdown occurs, and finally leading to a fire caused by the additional equipments. Therefore, additional equipment established on the vehicle due to a fire in order to prevent accidents during the manufacturing process of these devices are installed. If not installed unless the manufacturing process, the installation of additional equipments established by professional who knows the vehicle structure that will be able to prevent the fire.

Performance Analysis of CAN-FD Based Network Against Network Topology (네트워크 토폴로지에 따른 CAN-FD 통신 영향성 분석)

  • Seo, Sukhyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.6
    • /
    • pp.351-358
    • /
    • 2017
  • The most common communication interface for automotive electronic control devices is CAN (Controller Area Network). Sine CAN was first adopted to Daimler vehicles in 1991, all of automobile manufacturers use the CAN communication for in-vehicle networks. However, as the number of electronic control devices connected to the CAN network rapidly increases, the CAN protocol reaches the limit of technology. To overcome this limitation, Bosch introduced the new communication protocol, that is CAN-FD (Flexible Data-rate). In this paper, we analyze the characteristics and limitations of CAN-FD communication according to the topology under the in-vehicle wiring harness environment designed based on the existing classic CAN communication.

Development of Transparent Conductive Patterned Film with Hybrid Ag Ink

  • Choe, Ju-Hwan;Baek, Su-Jin;Lee, Beom-Ju;Sin, Jin-Guk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.2.3-2.3
    • /
    • 2011
  • With increased interest in printed devices, various metal nano inks have been investigated as candidates materials for printed electrodes and wiring as well as conductive film substituting photo-lithography process. Recent advances in organic conductive polymer allow us to fabricate high performance printed device. Meanwhile, there was several attempts to fabricate conductive films by mixing conductive polymer with metal nano-particle or nano-wires. The presence of Ag nanowires in conductive polymer mixture have shown good potential in organic photovoltaic devices.

  • PDF

The ATM Switching Architecture using Free-Space Optical Interconnections and Packets with a Parallel Form (자유공간 광 연결과 병렬 형태의 패킷을 이용한 ATM 교환 방식)

  • 장진환;갑상영;지윤규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.10
    • /
    • pp.8-16
    • /
    • 1992
  • Despite recent advances in electrical switch architectures, the practical switch performance is limited by both the technological and physical constraints of electrical device and wiring. Though an optical switch can have good features, optical devices are of poor quality. Therefore, we propose and study the switching architecture based on free-space optical interconnections and electrical logic devices. And an exchanging method using packets with a parallel form is introduced to solves the blocking problem of the switch that resulted from switching packets with a serial form. The free-space optical interconnections overcome the defects of electrical switch, such as, the complex connections of the wires. The proposed and demonstrated switch is nonblocking, simple and high performable. Other attractive features of the proposed switch include the guarantee of first-in first-out packet sequence. In this thesis, we also discuss the performance of proposed switch and show the experimental results of the 4$\times$4 switch.

  • PDF

One-wire In-Vehicle Controller Design and Manufacturing by DC-PLC Scheme

  • Lee, Geum-Boon;Kim, Nam-Gon;Lee, Ji-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • In this paper, DC-PLC typed one-wire controller was designed and manufactured especially for In-vehicle safe devices. One-wire by DC-PLC scheme is to be used as a power supply and ground to process the sensor data and to operate the vehicle actuators. To avoid complicate wires, we use the conventional wires without installing extra communication lines. The data collected from the sensors are transmitted to the main controller, processed by programming, and run the actuators corresponding to the commands sending to vehicle control board. The proposed method shows that only One-wire without requiring several wires make In-vehicle control devices simple and reduce the damage due to the loss of the wiring.

The Construction of AHU Control Network by Power Line Communication (전력선 통신에 의한 공기조화설비 제어네트워크 구축)

  • Kim, Myungho;Ahn, Kyochol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.7-11
    • /
    • 2008
  • In order to enhance standardization and interoperability of local level systems, AHU control network was designed with basement(8 point) and basis story(15 point) and then the network was constructed by power line communication. Each devices of AHU system were programed with neuron C of $L_{ON}W_{ORKS}$ as an open protocol. As a result of a study, each devices of the network were controlled with self dispersion process by $L_{ON}W_{ORKS}$ protocol and wiring could be reduced by power line communication.

  • PDF

Toughnening of Dielectric Material by Thermoplastic Polymer

  • Lee, Jung-Woo;Cho, Jae-Choon;Ra, Seung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.207-208
    • /
    • 2007
  • Recently, high performance microelectronic devices are designed in multi-layer structure in order to make dense wiring of metal conductors in compact size. Imprint lithography have received significant attention due to an alternative technology for photolithography on such devices. In this work, we synthesized dielectric composite materials based on epoxy resin, and investigated their thermal stabilities and dynamic mechanical properties for thermal imprint lithography. In order to enhance the mechanical properties and toughness of dielectric material, various modified polyetherimide(PEI) was applied in the resin system. Curing behaviours, thermal stabilities, and dynamic mechanical properties of the dielectric materials cured with various conditions were studied using dynamic differential scanning calorimetry (DSC), thermo gravimetric analysis (TGA), and Universal Test Method (INSTRON).

  • PDF

A study on the wire reduction design and effect analysis for the train vehicle line (철도차량 배선절감 방안 및 효과분석에 관한 연구)

  • Lee, Kangmi;Kim, Seong Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.711-717
    • /
    • 2017
  • The railway is a public transportation system that provides large-scale passenger transportation and service, whose reliability and safety is the top priority. The wiring of railway vehicles is classified into train control lines (train lines) and communication lines. The train lines are used for input / output signals related to vehicle driving and safety functions, and the communication lines are used for the input / output signals for passenger services such as broadcasting. In order to measure the reliability of railway vehicles, a train line is applied to the input / output interface of the control signals between the electric control devices in the vehicle, and there are many electromechanical devices such as relays and contactors for the control logic. In fact, since the vehicle control circuit is composed of several thousand contacts, it is difficult to check for errors such as contact failure, and it is impossible to check the real-time status, so a lot of manpower and time is required for regular maintenance. Therefore, we analyze the current state of the train line design of the electric equipment used for driving and services in domestic railway cars and propose three wiring reduction methods to improve it. Based on the analysis of domestic electric vehicles, it was confirmed that the wiring reduction effect is 35% or more.

The Thermal Characteristics of Partially Disconnected Wire Happened in Plug (플러그 내부에서 발생된 소선 단선에 의한 발열특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

Evaluation of wireless communication devices for remote monitoring of protected crop production environment (시설재배지 환경 원격 모니터링을 위한 무선 통신 장비 평가)

  • Hur, Seung-Oh;Ryu, Myong-Jin;Ryu, Dong-Ki;Chung, Sun-Ok;Huh, Yun-Kun;Choi, Jin-Yong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.747-752
    • /
    • 2011
  • Wireless technology has enabled farmers monitor and control protected production environment more efficiently. Utilization of USN (Ubiquitous Sensor Network) devices also brought benefits due to reduced wiring and central data handling requirements. However, wireless communication loses signal under unfavorable conditions (e.g., blocked signal path, low signal intensity). In this paper, performance of commercial wireless communication devices were evaluated for application to protected crop production. Two different models of wireless communication devices were tested. Sensors used in the study were weather units installed outside and top of a greenhouse (wind velocity and direction, precipitation, temperature and humidity), inside ambient condition units (temperature, humidity, $CO_2$, and light intensity), and irrigation status units (irrigation flow and pressure, and soil water content). Performance of wireless communication was evaluated with and without crop. For a 2.4 GHz device, communication distance was decreased by about 10% when crops were present between the transmitting and receiving antennas installed on the ground, and the best performance was obtained when the antennas were installed 2 m above the crop canopy. When tested in a greenhouse, center of a greenhouse was chosen as the location of receiving antenna. The results would provide information useful for implementation of wireless environment monitoring system for protected crop production using USN devices.