• Title/Summary/Keyword: Wireless X-ray

Search Result 21, Processing Time 0.03 seconds

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Magnetic Properties of Mn-substituted Magnetite Thin Films (망간 치환된 마그네타이트 박막의 자기적 특성 연구)

  • Lee, Hee-Jung;Kim, Kwang-Joo
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.262-266
    • /
    • 2007
  • Polycrystalline $Mn_xFe_{3-x}O_4$ thin films were synthesized on Si(100) substrates using sol-gel method and the effects of Mn substitution on the structural, magnetic, and magnetotransport properties were analyzed. X-ray diffraction revealed that cubic structure is maintained up to x = 1.78 with increasing lattice constant for increasing x. Such increase of the lattice constant is attributable to the substitution of $Mn^{2+}$ (with larger ionic radius) ions into tetrahedral $Fe^{3+}$(with smaller ionic radius) sites. VSM measurements revealed that $M_s$ does not vary significantly with x, qualitatively explainable by comparing spin magnetic moments of Mn and Fe ions. On the other hand, $H_c$ was found to decrease with increasing x, attributable to the decrease of magnetic anisotropy due to the decrease of $Fe^{2+}$ density through $Mn^{2+}$ substitution. Magnetoresistance (MR) of the $Mn_xFe_{3-x}O_4$ films was found to decrease with increasing x. Analysis of the MR data in comparison with the VSM results gives an indication of the tunneling of spin-polarized carriers through the grain boundaries of the polycrystalline samples at low external field and spin-flip of the carriers at high external field.

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Effects of Tube Voltage and Tube Current on Exposure Index : Focused on Radiographic Images of Cone Pyramid Phantom (관전압과 관전류량이 노출 지수에 미치는 영향 : 원뿔형 피라미드 팬텀 방사선영상 중심으로)

  • Seoung, You-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.749-755
    • /
    • 2019
  • In this study, we investigated the effects of tube voltage (kVp) and tube current (mAs) on an exposure index (EI) applied to a digital radiography. There used an inverter type digital X-ray generator and an image receptor (IR) utilized a portable wireless detector without a grid. Radiographic images were acquired using a cone pyramid phantom produced using a 3D printer. The X-ray tube voltage was increased from 40 kVp to 120 kVp with 10 kVp increment, and the tube current was increased from 1 mAs to 128 mAs with the twice increment. As a result, kVp had logarithmic relationship with the EI as high $R^2$ value, and mAs had a very high linear relationship too. Also, there was a high correlation between the area dose and the EI of the IR, with the $R^2$ value being 0.76 or more. In conclusion, it had showed that mAs affected the EI linearly, and that it could be advantageous to adjust the easy-to-predict mAs to maintain proper image qualities.

Implementation of PACS using PDA System on Medical Images (PDA기반 의료영상의 전송시스템 구현)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system) is a system that enables medical images such as X -ray, CT, MRI, PET to be stored electronically viewed on computer screens so that doctors and other authorized people can access search the information as needed. But if they are not in hospital area for example on holiday or at night, that are not able to access the PACS system instantly. We have to solve this problem for more efficient patient care. So we try to suggest a method that use the PDA system that wireless LAN and CDMA cellular phone are equipped. This system may help to access easier to PACS system regardless of the location and can also attribute the development of telemedicne.

Fabrication of a Magnetostrictive Transpositioner using Thin Film Deposition and MEMS Techniques (박막성형 기술 및 MEMS 공정을 이용한 자기변형 위치변환기)

  • Lee, Heung-Shik;Cho, Chong-Du;Lee, Sang-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1617-1620
    • /
    • 2007
  • This paper presents a magnetostrictive transpositioner and its fabrication process. To get a transposition movement without shifting or twisting, it is designed as an array type. To fabricate the suggested design, micromachining and selective DC magnetron sputtering processes are combined. TbDyFe film is sputter-deposited on the back side of the bulk micromachined transpositioner, with the condition as: Ar gas pressure below $1.2{\times}10^{-9}$ torr, DC input power of 180W and heating temperature of up to $250^{\circ}C$ for the wireless control of each array component. After the sputter process, magnetization and magnetostriction of each sample are measured. X-ray diffraction studies are also carried out to determine the film structure and thickness of the sputtered film. For the operation, each component of the actuator has same length and out-of-plane motion. Each component is actuated by externally applied magnetic fields up to 0.5T and motion of the device made upward movement. As a result, deflections of the device due to the movement for the external magnetic fields are observed.

  • PDF

Ethylenediamine Based Surface Defect Passivation for Enhancing Indoor Photovoltaic Efficiency of Perovskite (페로브스카이트 실내 광전변환 효율 향상을 위한 ethylenediamine 기반의 표면 결함 부동화 연구)

  • Seok Beom Kang;Joo Woong Yoon;Chang Yong Kim;Sangheon Lee;Hyemin Lee;Dong Hoe Kim
    • Current Photovoltaic Research
    • /
    • v.11 no.3
    • /
    • pp.87-95
    • /
    • 2023
  • As the demand for the Internet of Things grows, research into indoor photovoltaics for wireless power is becoming important. In particular, perovskite has attracted considerable attention due to its superior performance compared to other candidates. However, various surface defects present in perovskite are a limiting factor for high performance. In particular, deep-level surface defects caused by uncoordinated Pb2+ ions directly limit charge transport. In low light environments, this appears to be a more significant hurdle. In this study, ethylenediamine, which can provide covalent bonding to uncoordinated Pb2+ ions through nitrogen, was used as a surface treatment material for indoor photovoltaics. X-ray photoelectron spectroscopy confirmed that the uncoordinated Pb2+ ions were effectively passivated by the terminal nitrogen of ethylenediamine. As a consequence, a VOC of 0.998 V, a JSC of 0.139 mA cm-2 and a fill factor of 83.03% were achieved, resulting in an indoor photoelectric conversion efficiency of 38.02%.

Planar Type Flexible Piezoelectric Thin Film Energy Harvester Using Laser Lift-off

  • Noh, Myoung-Sub;Kang, Min-Gyu;Yoon, Seok Jin;Kang, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.489.2-489.2
    • /
    • 2014
  • The planar type flexible piezoelectric energy harvesters (PEH) based on PbZr0.52Ti0.48O3 (PZT) thin films on the flexible substrates are demonstrated to convert mechanical energy to electrical energy. The planar type energy harvesters have been realized, which have an electrode pair on the PZT thin films. The PZT thin films were deposited on double side polished sapphire substrates using conventional RF-magnetron sputtering. The PZT thin films on the sapphire substrates were transferred by PDMS stamp with laser lift-off (LLO) process. KrF excimer laser (wavelength: 248nm) were used for the LLO process. The PDMS stamp was attached to the top of the PZT thin films and the excimer laser induced onto back side of the sapphire substrate to detach the thin films. The detached thin films on the PDMS stamp transferred to adhesive layer coated on the flexible polyimide substrate. Structural properties of the PZT thin films were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). To measure piezoelectric power generation characteristics, Au/Cr inter digital electrode (IDE) was formed on the PZT thin films using the e-beam evaporation. The ferroelectric and piezoelectric properties were measured by a ferroelectric test system (Precision Premier-II) and piezoelectric force microscopy (PFM), respectively. The output signals of the flexible PEHs were evaluated by electrometer (6517A, Keithley). In the result, the transferred PZT thin films showed the ferroelectric and piezoelectric characteristics without electrical degradation and the fabricated flexible PEHs generated an AC-type output power electrical energy during periodically bending and releasing motion. We expect that the flexible PEHs based on laser transferred PZT thin film is able to be applied on self-powered electronic devices in wireless sensor networks technologies. Also, it has a lot of potential for high performance flexible piezoelectric energy harvester.

  • PDF

Characteristics of ZnO thin films by RF magnetron sputtering for FBAR application (RF 마그네트론 스퍼터링을 이용한 FBAR 소자용 ZnO 박막의 특성)

  • Kim, S.Y.;Lee, N.H.;Kim, S.G.;Park, S.H.;Jung, M.G.;Shin, Y.H.;Ji, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1523-1525
    • /
    • 2003
  • Due to the rapid development of wireless networking system, researches on the communication devices are mainly focus on microwave frequency devices such as filters, resonators, and phase shifters. Among them, Film bulk acoustic resonator (FBAR) has been paid extensive attentions for their high performance. In this research, ZnO thin films were deposited by RF-magnetron sputtering on Al/$SiO_2$/Si wafer and then crystalline properties and surface morphology were examined. To measure crystalline structure and surface morphology X-ray diffraction (XRD) and Scanning Electron Microscope (SEM) were employed. It was showed that crystalline properties of ZnO thin films were strongly dependant on the deposition conditions. As increasing the deposition temperature and the deposition pressures, the peak intensities of ZnO(002) plane were increased until $300^{\circ}C$, then decreased rapidly. At the sputtering conditions of RF power of 213 W and working pressure of 15 m Torr, ZnO film had excellent c-axis orientation, surface morphology, and adhesion to the substrate. In conclusion we optimized smooth surface with very small grains as well as highly c-axis oriented ZnO film for FBAR applications.

  • PDF