• Title/Summary/Keyword: Window-effect

Search Result 741, Processing Time 0.033 seconds

The Site of Vision in the Villa Savoye of Le Corbusier -'Fenetre en longueur' and the Internalization of a Distant View - (Le Corbusier 사브와 주택에서의 시각의 자리 - 수평창과 원경의 내면화 -)

  • Chung, Mann-Young
    • Journal of architectural history
    • /
    • v.7 no.2 s.15
    • /
    • pp.77-90
    • /
    • 1998
  • This study on the site of vision in the Villa Savoye of Le Corbusier, concentrates on the precise analysis of the meaning of 'fenetre on longueur' in the living room. A lots of architectural theorists have regarded the Villa Savoye of Le Corbusier as a symbol of modern architecture, and his 'fenetre on longueur' as products of modern technology. But Le Corbusier who defined himself as 'homme visuel', responded keenly to the vision conditions inherent to the human finitude, Indifferent to the modern technology, Such a response would be derived from the experience of Acropolis, where 'the scheme was designed to be seen from a distance.' Generally speaking, 'fenetre en longueur', contra to 'porte-fenetre', makes one to focus on the panorama effect of the horizon, including a distant view. Entering the living room of Villa Savoye, however, we may perceive this window in two ways. Firstly this window acts as a screen to obstruct not to see outside, because of the wall above pressing down the line of view. Secondly this acts as a frame to make us see a distant view as far as eye can reach. These two ways result in the abbreviation of near view, and a sudden shift between a inferiority(derived from 'screen effect') and a distant view(from 'frame effect'). Depending on such a observation, this study can evaluate 'fenetre en longueur' internalizing of a distant view as the highest compressed scene of Le Corbusier's architectural poetics.

  • PDF

Performance Analysis of The CCITT X.25 Protocol (X. 25 Protocol의 성능 분석)

  • 최준균;은종관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.1
    • /
    • pp.25-39
    • /
    • 1986
  • In this paper, we analyze the performance, particularly the flow control mechanism, of the CCITT X.25 protocol in a packet-switched network. In this analysis, we consider the link and packet layers separately, and investigate the performance in three measures; normalized channel throughput, mean transmission time, and transmission efficiency. Each of these measures is formulated in terms of given protocol parameters such as windos size, $T_1$ and $T_2$ values, message length, and so forth. We model the service procedure of the inpur traffic based on the flow control mechanism of the X.25 protocol, and investigate the mechanism of the sliding window flow control with the piggybacked acknowlodgment scheme using a discrete-time Markov chain model. With this model, we study the effect of variation of the protoccol parameters on the performance of the X.25 protocol. From the numerical results of this analysis one can select the optimal valuse of the protocol parameters for different channel environments. it has been found that to maintain the trasnmission capacity satisfactorily, the window size must be greater than or equal to 7 in a high-speed channel. The time-out value, $T_1$, must carefully be selected in a noisy channel. In a normal condition, it should be in the order of ls. The value of $T_2$ has some effect on the transmission efficiency, but is not critical.

  • PDF

Estimation on the Interior and Outside Aircraft Noise Level of Residential House (주거용 건물의 실내.외 항공기소음레벨 평가)

  • Bang, Min;Kim, Do-Heong;Kim, Heung-Sik;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.687-691
    • /
    • 2007
  • It is important to increase the sound proof performance of building for reducing the influence of aircraft noise on the bais of actual survey of existed buildings. The purpose of this study is to propose the basic data for designing sound insulation of residential house. In this study, field measurement of aircraft noise Interior and outside noise level difference were carried out for 7 days in 2 residential houses. As the result, aircraft noise levels showed to be Leq $71.8{\sim}74.5$dB(A), WECPNL $82.2{\sim}83.4$ and indoor noise level were NC-55 ${\sim}63$ over acceptable NC-30 in 2 measured houses. Noise reduction effect showed to be $15.8{\sim}23.1$dB(A) in measured houses, and houses with double window were preferable to those with single window in sound proof performance. The outside sound pressure level for residential house was a little different according to the type of source. In measuring by using aircraft noise it was effected by angle and distance from measuring point, to aircraft, window area, and sound absorption of room, and so on.

  • PDF

A Study on Characteristics of Main Indoor Air Pollutants and Ventilation in Nursery Facilities (어린이집 실내공기 중 주요 오염물질의 특성 및 환기에 관한 연구)

  • Kim, Sang Cheol;Kang, Byeong-Chang;Lee, Sang-Uk;Kim, Gi-Doo;Seo, Won-Ho;Kim, Jong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2014
  • As the number of nursery facilities and infants who stay there is continuously increasing, IAQ (Indoor Air Quality) of nursery facilities should be managed strictly and thoroughly because infants are more susceptible to infections due to their low resistivity. In this study the characteristics of IAQ and ventilation associated factors were investigaed for suggesting a desirable condition for IAQ management. Environmental factors were not much related to IAQ characteristics rather than internal factors such as structures of the room. And the positive effect of ventilation on IAQ was obvious and seemed to hinge on factors related to window area especially window/wall ratio. Results of this study indicate that the structure with broader window area of a room and frequnet ventilation can be an effective way for keeping IAQ of nursery facilities clean and safe.

A New Approach far Reducing Audible Noise in Mobile TFT LCD Module (모바일 TFT-LCD 모듈에서 발생하는 가청잡음을 줄이기 위한 새로운 방법)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.540-543
    • /
    • 2007
  • In this paper, we propose a new approach to reduce the audible noise generated by TFT-LCD module in mobile applications. We also analyzed impact factors which effect on the audible noise. It is expected that this noise source comes from various impact factors such as vibration of flexible printed-circuit board (FPCB) and LCD panel, and static electricity charged in window and back-light unit. Windowless type and window type models are evaluated to analyze noise level due to the static electricity charged in window. To obtain reliable and reproducible data, we constructed controllable test jig and measurement set-up.

  • PDF

Practical Pinch Torque Detection Algorithm for Anti-Pinch Window Control System Application

  • Lee, Hye-Jin;Ra, Won-Sang;Yoon, Tae-Sung;Park, Jin-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2526-2531
    • /
    • 2005
  • A practical pinch torque estimator based on the Kalman filter is proposed for low-cost anti-pinch window control systems. To obtain the accurate angular velocity from Hall-effect sensor measurements, the angular velocity calculation algorithm is executed with additional procedures for removing the measurement noises. Apart from the previous works using the angular velocity estimates and torque estimates for detecting the pinched condition, the torque rate is augmented to the system model and the proposed pinch estimator is derived by applying the steady-state Kalman filter recursion to the model. The motivation of this approach comes from the idea that the bias errors in torque estimates due to the motor parameter uncertainties can be almost eliminated by introducing the torque rate state. For detecting the pinched condition, a systematic way to determine the threshold level of the torque rate estimates is also suggested via the deterministic estimation error analysis. Simulation results are given to certify the pinch detection performance of the proposed algorithm and its robustness against the motor parameter uncertainties.

  • PDF

Energy Saving by Combination of Element Technologies of Zero-Energy House (제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구)

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

A Study on the Analysis of Building Energy Rating considering the Region (지역에 따른 주거용 건물에너지효율등급 분석 연구)

  • Ahn, Byung-Lip;Kim, Chi-Hoon;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

A Study on the Evaluation of Building Energy Rating considering the Region of Apartment Houses (공동주택에서의 지역에 따른 건물에너지 효율등급 평가 연구)

  • Ahn, Byung-Lip;Kim, Chi-Hoon;Kim, Ji-Yeun;Jang, Cheol-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.15-20
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

  • PDF

Causality join query processing for data stream by spatio-temporal sliding window (시공간 슬라이딩윈도우기법을 이용한 데이터스트림의 인과관계 결합질의처리방법)

  • Kwon, O-Je;Li, Ki-Joune
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.219-236
    • /
    • 2008
  • Data stream collected from sensors contain a large amount of useful information including causality relationships. The causality join query for data stream is to retrieve a set of pairs (cause, effect) from streams of data. A part of causality pairs may however be lost from the query result, due to the delay from sensors to a data stream management system, and the limited size of sliding windows. In this paper, we first investigate spatial, temporal, and spatio-temporal aspects of the causality join query for data stream. Second, we propose several strategies for sliding window management based on these observations. The accuracy of the proposed strategies is studied by intensive experiments, and the result shows that we improve the accuracy of causality join query in data stream from simple FIFO strategy.

  • PDF