• Title/Summary/Keyword: Window opening

Search Result 129, Processing Time 0.023 seconds

A Study on the Psychological effects of glass in Modern Interior Architecture -focused on Mies van der Rohes House Projects- (현대 실내 건축에 있어서 유리가 미친 심리적 영향에 관한 연구 -Mies van der Rohe의 주택을 중심으로-)

  • 문정묵
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.103-110
    • /
    • 2000
  • The material world around human is normally composed of opaque one, with which human has made the spaces. The opaque material to make space has played a role to control the relationship among people and has produced socio-cultural things since the history started. The opening of opaque material(wall) connects one space with the other. Therefore, the meaning of opening is a connection among people who are in different spaces in terms of sociology. In conjunction with this, socio-cultural situation has been deployed differently. In the traditional european domestic space, the glass has been applied to this opening since they found the glass. It disconnects two spaces physically but connects them visually. Therefore, without blocking the opening visually, the glass became to protect people with their interior space from outside environment. The important thing is that the application of the glass in a building had been restricted because of opening size. However, after Industrial Revolution with the advanced technology of architecture, the glass came to be applied to the building and it became widen. So, the concept of glass window became to be the one of glass wall. This change made a transformation of visual character between two spaces which are separated with glass wall. This means that the glass wall gave two directional visibility while the glass window gave one directional visibility from inside to outside of space. This is because the amount of the natural light to the interior space increased due to widen glass in a space. This gave a change of visual authority and the space of surveillance(interior space) became to the one of communication. The space of surveillance, Michel Foucault mentioned in his book surveillance and punishment, is a very private one that is not visually permeable from the people outside, while the space of communication is a public one which needs other eyes. In the space of publicity, there needs a rationality, morality and ethics because of public surveillance and in the space of privacy, there restores a desire for sex and assaults.

  • PDF

A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.

A study on the transition of the type of openings constructed at backside of DAECHUNG in Korean traditional architectures (전통건축 대청 배면 개구부형식의 변천에 관한 연구)

  • 정명섭
    • Journal of the Korean housing association
    • /
    • v.5 no.2
    • /
    • pp.29-40
    • /
    • 1994
  • The purpose of this study is to survey the transition of the type of openings in korean traditional archiectures. To do this, various types of openings at the backside of Daechung of 23 Hyang-Gyo Myung-Ryun-Dangs were investigated. After the classification in some groups according to their types and their periods of constuction, the tasnsition of the type of openings was analysed. Results are as follows. (1) The openings constructed form 16th to 17th century, the earliest form, is a ledged and battened panel window(or framed and ledged panel window) whose mullion is built on the frame of window. It is presumed that these types were widely used before 17th century. (2) The next type is ledged and battened panel window(door) (or framed and ledged panel window) which lacks a mullion. These types were thought to be customed after 18th century. (3) The lastest type, which is appeared from 19th to 20th century, is an characteristic backside opening(ledged and battened panel window or framed and ledged panel window) that among 3 column spacings the central one is enlarged in comparison with the right and left ones. Through this transition pattern of the openings, can be menifested that the trend of 20th century is to enlarge convenience of usage by constuctiong door and eliminating some windows.

  • PDF

A Study on the Actual Conditions and Responses of New Han-ok Inhabitants through Questionnaire - Focused in Jeonnam Province - (신한옥 주거 만족도 실태조사 연구 - 전라남도를 중심으로 -)

  • Song, Min-Jeong;Jang, Hyeon-Chung;Lee, Tai-Gang;Lee, Ju-Yeob;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.3-12
    • /
    • 2013
  • Recently, New Han-ok is in prevail because it has many good qualities as a dwelling. But the New Han-ok dwellers' needs and satisfaction ratio on their houses are not investigated yet. So, surveys on satisfaction ratio for New Han-ok were carried out to know New Han-ok's existing conditions and inhabitant's responses on New Han-ok dwellings. Followings are results. 1) Dwellers response that it is cool in summer and it is cold in winter. So, design and construction method against cold is needed for New Han-ok. 2) Window is the most picking element of New Han-ok for house improvement. 3) Window opening is main control method for cooling in summer. Warming sources in winter are various such as electricity, gas, oil, wood, etc. 4) PVC window structure and glasses were used for New Han-ok's window system as well as wooden window structure and Han-gi. 5) Interviewees are generally satisfied with New Han-ok's exterior view and inner spaces. Almost no humidifier is used. These results could be used for improvement of Han-ok and basic material for New Han-ok design.

Wind Tunnel Investigation of Fluctuating Pressure inside Building (풍하중에 의한 건물내부 압력의 동적변화에 관한 연구)

  • Kyoung-Hoon Rhee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.10a
    • /
    • pp.63-68
    • /
    • 1990
  • The nature of fluctuating air pressure inside building was studied by testing a building model in a wind tunnel. The model has a single room and a sin81e window opening. Various opening conditions were tested in both laminar uniform wind and turbulent boundary-layer wind. The RMS and the spectra of the fluctuating internal pressure were measured. The test results support a recent theory which predicts the behavior of internal pressure under high wind based on aerodynamic analysis.

  • PDF

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Temperature Control of Greenhouse Using Ventilation Window Adjustments by a Fuzzy Algorithm (퍼지제어에 의한 자연환기온실의 온도제어)

  • 정태상;민영봉;문경규
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.42-49
    • /
    • 2001
  • This study was carried out to develop a fuzzy control technique of ventilation window for controlling a temperature in a greenhouse. To reduce the fuzzy variables, the inside air temperature shop was taken as one of fuzzy variables, because the inside air temperature variation of a greenhouse by ventilation at the same window aperture is affected by difference between inside and outside air temperature, outside wind speed and the wind direction. Therefore, the antecedent variables for fuzzy algorithm were used the control error and its slop, which was same value as the inside air temperature slop during the control period, and the conclusion variable was used the window aperture opening rate. Through the basic and applicative control experiment with the control period of 3 minutes the optimum ranges of fuzzy variables were decided. The control error and its slop were taken as 3 and 1.5 times compared with target error in steady state, and the window opening rate were taken as 30% of full size of the window aperture. To evaluate the developed fuzzy algorithm in which the optimized 19 rules of fuzzy production were used, the performances of fuzzy control and PID control were compared. The temperature control errors by the fuzzy control and PID control were lower than 1.3$^{\circ}C$ and 2.2$^{\circ}C$ respectively. The accumulated operating size of the window, the number of operating and the number of inverse operating for the fuzzy control were 0.4 times, 0.5 times and 0.3 times of those compared with the PID control. Therefore, the fuzzy control can operating the window more smooth and reduce the operating energy by 1/2 times of PID control.

  • PDF

Sound Absorption Performance of Korean Traditional Window Papers (창호지의 흡음성능에 관한 실험적 연구)

  • Choi, Eun-Seok;Lee, Tai-Gang;Kim, Hang;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.17-20
    • /
    • 2006
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to he standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound absorption characteristics according to difference in thickness and finishing method of window paper and those in sound absorption characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module (스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구)

  • Yoon, Jong-Ho;Kim, Dong-Su;Oh, Myung-Hwan;Lee, Jae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.