• 제목/요약/키워드: Window frame

검색결과 229건 처리시간 0.024초

관광상품개발을 위한 전통창살 문양의 티셔츠 디자인 연구 (T-shirts Design Using Traditional Window-Frame Pattern on Tourism Souvenir Development)

  • 신정숙;정혜정
    • 한국의상디자인학회지
    • /
    • 제3권2호
    • /
    • pp.121-135
    • /
    • 2001
  • Foreign tourists prefer a T-shirts as a souvenir and it can be used practically. The objective of this study is to development T-shirts design using traditional window frame pattern for tourism souvenir. T-shirts design applied traditional window-frame pattern, which is a geometrical figure among traditional shapes. The results are as follows. 1. Window-frame pattern were general shape and complicated shape. 2. Window-frame pattern is visually ordered and stabled because has perfect ratio. 3. Geometrical line of window-frame applied on a T-shirt and match with modern sense.

  • PDF

PVC 창호의 구성에 따른 단열성능 예측에 관한 연구 (Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition)

  • 성욱주;이진성;조수;장철용;백상훈;송규동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

MAC Frame Aggregation이 가능한 에드혹 네트워크에서의 Congestion Window Limit을 통한 TCP 성능의 최적화 (TCP Performance Optimization Using Congestion Window Limit in Ad Hoc Networks with MAC Frame Aggregation)

  • 강민우;박희민;박준상
    • 한국ITS학회 논문지
    • /
    • 제9권4호
    • /
    • pp.52-59
    • /
    • 2010
  • 무선 애드혹 네트워크에서 MAC layer의 효율을 높이기 위한 하나의 방법으로서 사용되는 MAC frame aggregation은 MAC layer에서 여러 개의 MPDU (MAC protocol data units)를 하나의 PPDU (PHY protocol data units)로 aggregation 시켜서 성능을 향상시키는 방법이다. 애드혹 네트워크에서 TCP 성능 향상을 위해서 사용되는 방법의 하나로서 CWL (congestion window limit)의 설정 방법이 있는데 이는 congestion window의 상한을 두어 부적절한 congestion window 크기가 선택에 따른 영향을 최소화 하고자 하는 방법이다. 본 논문에서는 MAC frame aggregation이 가능한 MANET에서 최적화된 TCP 성능을 위하여 CWL를 조정하는 방법에 대하여 다룬다.

Improvement of the PVC Window Frame Installation Method Integrated with Gangform and Field Applicability Analysis

  • Choi, Hyo-Sung;Lee, Jeong-Ho;Yoo, Huyn-Seok;Kim, Young-Suk;Han, Seung-Woo
    • 한국건축시공학회지
    • /
    • 제11권5호
    • /
    • pp.482-500
    • /
    • 2011
  • In apartment housing construction, window frame installation work, which is conducted after the structural framework, is very important, because its completion time directly affects the starting time of successive interior finishing works, as well as the overall construction period. Construction delays in interior finishing works might occur due to problems inherent to the conventional window frame installation method, such as the poor verticality of window frames, and the water leakage around them. The primary objective of this study is to analyze the problems of a 'Gangform integrated PVC window frame pre-installation method' based on its pilot test results. Next, this study proposes an improved conceptual model that enables the end users to enhance the field applicability of this method in terms of productivity, time, and cost. The field applicability of the proposed 'Gangform integrated PVC window frame pre-installation method' was also verified through a survey.

창호일체형 태양열 집열기 (Window Integrated Solar Collectors)

  • 박성배;임성환;박만귀
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

창문 열관류율 저감을 위한 열교 저감형 보강재 연구 (A Study on the Thermal Bridge Reduced Stiffeners for the Reduction of Window Overall Hear Transfer Coefficient)

  • 장혁수;김영일;정광섭
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.71-80
    • /
    • 2015
  • PVC 프레임의 취약한 강도를 보완하기 위해 사용되는 철재 보강재는 상대적으로 높은 열전도 특성으로 인해 PVC 프레임의 전체적인 열 성능을 떨어뜨리는 역할을 한다. 본 연구는 철재 보강재의 타공을 통해 표면적을 줄임으로서 전열 면적의 감소를 통한 열저항 특성을 개선하고, 감소된 만큼 두께를 높임으로서 타공으로 인한 강도 저하를 보완하였다. 이에 대한 성능을 평가하기 위해 PVC frame, PVC frame + original steel stiffener, PVC frame + 30% perforated steel stiffener, PVC frame + 50% perforated steel stiffener, PVC frame + 65% perforated steel stiffener 등 5개의 시험체를 구성하였으며, 시험 방법은 수식과 시뮬레이션에 의한 방법을 적용하였다. 시험 결과 PVC frame + 65% perforated steel stiffener이 열저항 특성과 강도특성에서 가장 높은 것으로 평가되었다.

CHARACTERIZATION OF RATIONAL TIME-FREQUENCY MULTI-WINDOW GABOR FRAMES AND THEIR DUALS

  • Zhang, Yan;Li, Yun-Zhang
    • 대한수학회지
    • /
    • 제51권5호
    • /
    • pp.897-918
    • /
    • 2014
  • This paper addresses multi-window Gabor frames with rational time-frequency product. Such issue was considered by Zibulski and Zeevi (Appl. Comput. Harmonic Anal. 4 (1997), 188-221) in terms of Zak transform matrix (so-called Zibuski-Zeevi matrix), and by many others. In this paper, we introduce of a new Zak transform matrix. It is different from Zibulski-Zeevi matrix, but more direct and convenient for our purpose. Using such Zak transform matrix we characterize rational time-frequency multi-window Gabor frames (Riesz bases and orthonormal bases), and Gabor duals for a Gabor frame. Some examples are also provided, which show that our Zak transform matrix method is efficient.

창틀 공기층의 유효 열전도율(λeff) 산정방법 차이가 창 전체 열관류율(Uw) 시뮬레이션 결과에 미치는 영향에 대한 비교 분석 - 단창 창틀의 비환기 공기층에 대한 시뮬레이션을 중심으로 - (A comparative analysis of the total window thermal transmittance simulation result according to the evaluation method of effective conductivity(λeff) of frame cavity - Focused on unventilated frame cavity simulation results of single window -)

  • 이용준;오은주;김사겸;최경석;강재식
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.79-85
    • /
    • 2016
  • Purpose: It is difficult to calculate frame U-value because of the two reason. First is selection of air properties in cavity. Second is calculation method in window frame. For this reason, it is important to decide cavity properties in window frame. However, international standards offered different method(ISO 15099, ISO 10077) and air properties was changed according to the two methods. The aim of this study was to suggest method for deriving accurate frame U-value using international standard methods and CFD simulation. Method: First, this study conducted analysis calculation method of ISO 15099 and ISO 10077. And, CFD simulation conducted based on same condition. Finally, ISO calculation and CFD simulation results were verified through comparison with real experiment results. Result: The results show that effective conductivity of ISO 15099 was the highest value. ISO 10077 and CFD result followed. The convergent values of ISO 10077 was the highest. ISO 15099 and CFD followed. ISO calculation reflecting CFD simulation results will reduce error with experimental results.

Experimental and numerical investigations into the composite behaviour of steel frames and precast concrete infill panels with window openings

  • Teeuwen, P.A.;Kleinman, C.S.;Snijder, H.H.;Hofmeyer, H.
    • Steel and Composite Structures
    • /
    • 제10권1호
    • /
    • pp.1-21
    • /
    • 2010
  • As an alternative for conventional structures for tall buildings, a hybrid lateral load resisting structure has been designed, enabling the assembly of tall buildings directly from a truck. It consists of steel frames with discretely connected precast concrete infill panels provided with window openings. Besides the stiffening and strengthening effect of the infill panels on the frame structure, economical benefits may be derived from saving costs on materials and labour, and from reducing construction time. In order to develop design rules for this type of structure, the hybrid infilled frame has recently been subjected to experimental and numerical analyses. Ten full-scale tests were performed on one-storey, one-bay, 3 by 3 m infilled frame structures, having different window opening geometries. Subsequently, the response of the full-scale experiments was simulated with the finite element program DIANA. The finite element simulations were performed taking into account non-linear material characteristics and geometrical non-linearity. The experiments show that discretely connected precast concrete panels provided with a window opening, can significantly improve the performance of steel frames. A comparison between the full-scale experiments and simulations shows that the finite element models enable simulating the elastic and plastic behaviour of the hybrid infilled frame.

단열재 두께 변화와 창호 침기 부하와의 관계 (A Study on Relationship Insulation Thickness and Infiltration Load by Window)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.