• Title/Summary/Keyword: Window System

Search Result 1,657, Processing Time 0.028 seconds

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

Analysis of Gas Cooling System for IR Window (적외선 윈도우용 가스식 냉각장치 해석 기법)

  • Hyun, Cheol-Bong;Goo, Nam-Seo;Kim, Jae-Young;Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.130-137
    • /
    • 2012
  • In this paper, a post-analysis of cooling system for infrared(IR) window was performed based on heating experiment of IR window system. We applied the same experimental conditions to analysis, and then validated the analysis technique by comparing numerical and experimental results. For an analysis software, we used a professional heat/fluid analysis program and the numerical and experimental results were in fairly good agreement. We investigated the effect of thermal transfer between the frame and IR window and also a cooling efficiency between fluid and structure in order to determine the proper parameters for the analysis. In this study, 100 % thermal transfer between the frame and IR window and 30 % cooling efficiency between fluid and structure have been proposed, which can be used in the future conceptual design and analysis of similar IR windows.

A Study on The Independent-Platform-Remote-Management System (플렛폼에 독립적인 원격관리 시스템)

  • Kim, Yong-Gwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04a
    • /
    • pp.419-422
    • /
    • 2002
  • 현재 대표적인 OS 인 Window, Unix, Linux에 관계없이 클라이언트와, 서버의 OS 에 상관없이 원격으로 관리할 수 있는 시스템을 개발하고자하는데 그 목적을 두었다. 즉 클라이언트가 Linux상에 돌아가고 서버가 Window 에서 돌아가는 시스템에서 Window 의 자원을 클라이언트가 Linux 상에서 쓰고 제어할 수 있고 그 반대로 Linux의 자원을 Window에서 쓸수있음을 제시한다.

  • PDF

An Improved Rayleigh Fading Compensation Algorithm with Modified Sinc Interpolation (수정된 Sinc 보간법을 이용한 새로운 Rayleigh 페이딩 보상 알고리즘)

  • 이창재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10A
    • /
    • pp.1492-1498
    • /
    • 2000
  • Pilot symbol aided modulation (PSAM) using the conventional sinc interpolation (CSI) achieves nearly the same BER performance as Caver' optimal Wiener interpolation but with much less complexity. The CSI, however, has to use a non-rectangular window function that is applied to the sinc function to smooth out the abrupt truncation of rectangular window. In this paper, we propose the modified sinc interpolation (MSI). With the weighting factor the MSI scheme with no window has almost the same BER performance as the CSI scheme using window, In addition, if we use the MSI with a window its BER performance gets close to that of the theoretical one. We assume the multicarrier QAM system and an optimal frame structure for performance evaluation.

  • PDF

A comparative analysis of the simulation results of total window thermal transmittance(Uw) according to the evaluation method - Focused on comparison of the single window simulation results - (창세트 전체 열관류율(Uw) 평가 방법에 따른 시뮬레이션 결과 비교 분석 - 단창 창세트에 대한 시뮬레이션 결과 비교를 중심으로 -)

  • Lee, Yong-jun;Oh, Eun-joo;Kim, Sa-kyum;Choi, Hyun-jung;Kim, Yu-min
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The aim of this study is to calculate U-factor of the window using international standard methods and compare quantitative and tendency difference focused on ISO standard 15099 and ISO standard 10077. And the result of ISO standard calculation methods is verified using thermal performance experiment to evaluate applicability of domestic certification system. This study is utilized a basis for activation of domestic window certification system. Method: First, 16 cases are selected that is combined a variety of frame, Glazing, spacer, etc. The selected cases were simulated using WINDOW&THERM based on ISO 15099 and 10077 calculation method. Second, experiment was conducted based on Korean standard condition. Then, it was compared the error of experiment and simulation results. Through this process, ISO 15099 and 10077 calculation methods were evaluated accuracy and utilization. Result: The results show that the difference of ISO 15099 and ISO 10077-2 is maximum 5.4%. The results of comparing U-factor errors based on the Korea standard experiment test found 2.4%. Consequently, it will be possible to combination calculation methods of ISO 15099 and ISO 10077 for a single window.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

The Efficiency Analysis of Firms Having Established a Business Intelligence System Using DEA/Time-Window Analysis (DEA를 이용한 기업의 Business Intelligence 시스템 도입 효율성에 대한 비교 평가 연구)

  • Baek, Seong-Hyun;Park, Kwang-Ho;Kim, Tai-Young
    • Information Systems Review
    • /
    • v.17 no.3
    • /
    • pp.113-133
    • /
    • 2015
  • In this paper, DEA analysis is employed to compare and evaluate the relative efficiency of a business intelligence (BI) system among five industrial groups such as IT and financial services, electricity and electronics, energy and chemistry, automotive and heavy machinery, and food and apparel. Especially, this study has analyzed the improving tendency of relative efficiency of the industrial groups since they adopted the BI System using Time-Window Analysis. The research findings show that the energy and chemical industry group tends to be remarkably more efficient than the other groups and the electrical and electronic industry turns out to gradually improve their efficiency since the adoption of the BI system.

Merge Control using Reserve Ahead Point in Baggage Handling System (수하물시스템의 사전할당지점을 이용한 병합제어)

  • Kim, Minhee;Shin, Hyunwoo;Chae, Junjae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.2
    • /
    • pp.60-67
    • /
    • 2017
  • A baggage handling system (BHS) in airport is an unified system for moving the passengers' baggage in designated time. Input baggage from the check-in counter travels to the baggage claim area or cargo handling terminal through this system. In particular, entryway BHS consists of conveyors, X-ray and sorters such as tilt-tray to send the baggage to departing airplane and it could have various problems for handling certain amount of baggage in restricted time such as baggage jamming at certain merge point. This causes systemic error such as delay of the time, omissions of the baggage and even breakdown of the equipment and inefficiency. Also the increasing maximum time of the baggage passing through the BHS could delay the flight schedule and finally decrease the service level. Thus, the algorithm for controlling the flow of the merge is essential to the system. The window reservation algorithm is the one of the most frequently used methods to control the merge configuration. Above all, the reserve location, so called reserve ahead point, that allocates the window is important for the performance of the algorithm. We propose the modified window reservation algorithm and the best reserve locations by changing the reserve ahead point in the induction conveyors. The effect of various reserve ahead points such as the capacity and utility of the system were analyzed and the most effective reserve ahead point combination was found. The total baggage processing time and the utilization of the tilt-tray are properly considered when choosing the optimal Reserve ahead point combination. In the layout of this study, the configuration of four conveyors merged into one tilt-tray is studied and simulation analysis is done by AutoMod(R), 3D simulation software. Through the simulation, the window reservation algorithm is effectively operated with the best combination of reserve ahead point which reduces the maximum baggage travel time.

Analysis of Efficiency and Productivity Changes for Mail Centers Using DEA-Window Analysis and Malmquist Productivity Index (DEA-Window 분석 및 Malmquist 생산성지수를 사용한 우편집중국 효율성 및 생산성 변화 분석)

  • Lee, Jae-Seol;Goh, Hyun-Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.79-86
    • /
    • 2009
  • The purpose of this paper is to analyze the 24 mail center's efficiency and productivity changes from first quarter to fourth quarter of 2008 using window analysis and Malmquist productivity index. Row views of window analysis results make it possible to determine trends and/or observed behavior with the same data set, and column views to examine the stability of results across different data sets. Malmquist productivity indexes greater than unity translate into improvements in productivity, and less than unity mean deterioration in performance over time. The results of this study suggest that DEA models under dynamic situations such as window analysis and Malmquist productivity index enable us to comprehend the efficiency and productivity changes over time and to show the direction of improvements.

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF