• Title/Summary/Keyword: Window&Door

Search Result 126, Processing Time 0.027 seconds

A study on the Architectural Characteristics of Kyungduk-Dan and Manun-Jae in Miryang -Mainly about the Characterics of Traditional Houses in modern era(1876-1945)- (밀양(密陽) 경덕단(景德壇)과 만운재(萬雲齋)의 건축적 특성 - 근대한옥의 성격을 중심으로 -)

  • Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.10 no.1 s.25
    • /
    • pp.9-23
    • /
    • 2001
  • This study is for the Kyungduk-Dan(as a altar of Milsung-Daegun) and The Manun-Jae the characteristics(lay out and planning, window patterns, structure, materials) of the the Korean traditional house during the modern era. Before Manun-Jae was used for the house. The Kyungduck-Dan was constructed in August according to the Lunar Calender in 1927. The Manun-Jae(house for Ki-hun Kang, millionaire ) was completed in 1924. Modern Architectures brought to Korea with the bricks, the tiles, the flash doors, the plate grasses, the brass hardwares. These architectural material was used in positive. During the construction of Manun-Jae in 1924, it happened the architectural exchage among a korean, a chinese and a japanese constructor. Though using the air exhaust valve at the kitchen of Ukyung-Kak( old Anchae), it could be assume that the modern convenience and the improvement of residential environments was considered at that period during the construction of Manun-Jae. That construction was elected with the brick($222mm{\times}106mm{\times}50mm$), the chinese colored tile and plate glass such a modem materials. The new shape of the korean lattice window and the wooden flash-door with glass was used. In Ukyung-Kak, the Chan-Maru(service space) and the kitchen such as a service space or concise utility zone was organically connected. Especially, considered the domesitic activity and circulation, the western kitchen sink and the Chan-Maru(service space) was rationally placed. At the Manun-Jae and the Kyungduck-Dan, the architectural characteristic is that the new shape of windows was used. The lattice window at the Ondol room of Ukyung-Kak, was rgadually added the plate glass and the wood plate. The lattice window with the grid shape at kitchen of that building was adapted japanese grid lattice window in korea at that period. It is the sample that korean traditional house was typically influenced from the japanese resident culture. The Manun-Jae and the Kyungduck-Dan as the modern house kept the form of korean traditional architecture, and was partially adapted a modern characteristic space and modern architectural materials. During the japanese occupancy, these residence can be showed the transition in formally.

  • PDF

A Study on the Application of TACT Planning & Scheduling in Finish Work of Apartment Houses (공동주택 마감공사에서의 택트공정관리 적용에 관한 연구)

  • Yoon You-Sang;Suh Sang-Wook
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.422-425
    • /
    • 2003
  • The purpose of this study is using a TACT planning and scheduling for apartment houses construction that have many of same units. Because using a TACT planning and scheduling is concluded time reduction at same units as apartment plan. The main contents of this study are 1) window and door work through the field study, 2) adjust worker assignment to minimize work time variation, and 3) an effect of working time through a case study. As a result, the total working time can be improved $21.2\%$ by using the TACT planning and scheduling. The stu요 recommends that 1) establish an accurate data between work period and resource, and 2) preparation to measures minimization of waiting time before using a TACT planning and scheduling.

  • PDF

Interaction with Agents in the Virtual Space Combined by Recognition of Face Direction and Hand Gestures (얼굴 방향과 손 동작 인식을 통합한 가상 공간에 존재하는 Agent들과의 상호 작용)

  • Jo, Gang-Hyeon;Kim, Seong-Eun;Lee, In-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.3
    • /
    • pp.62-78
    • /
    • 2002
  • In this paper, we describe a system that can interact with agents in the virtual space incorporated in the system. This system is constructed by an analysis system for analyzing human gesture and an interact system for interacting with agents in the virtual space using analyzed information. An implemented analysis system for analyzing gesture extracts a head and hands region after taking image sequence of an operator's continuous behavior using CCD cameras. In interact system, we construct the virtual space that exist an avatar which incarnating operator himself, an autonomous object (like a Puppy), and non-autonomous objects which are table, door, window and object. Recognized gesture is transmitted to the avatar in the virtual space, then transit to next state based on state transition diagram. State transition diagram is represented in a graph in which each state represented as node and connect with link. In the virtual space, the agent link an avatar can open and close a window and a door, grab or move an object like a ball, order a puppy to do and respond to the Puppy's behavior as does the puppy.

Actual conditions on the Living Environment of Small-scale Group-homes for the Elderly (고령자용 소규모 그룹홈의 생활환경 실태)

  • Kim, Hyun-Jin;An, Ok-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.21-29
    • /
    • 2008
  • To investigate the actual conditions on the living environment of group-homes for the elderly and their living environment, 4 group-homes were surveyed. As the results, conditions of location for the group-home of the elderly looked positive, on the other hand, safety for criminal prevention, accessability and convenient facilities were not on level satisfied. The average area of each space in the group-home indicated that the bed room was $11.21\;m^2$, the living room $28.13\;m^2$, the kitchen $23.59\;m^2$, and the bath room had an integrated type of bath room and toilet $7.63\;m^2$. The physical environments of each space in the group-home were investigated, In bed room, door, windows and illumination were relatively good but safety was extremely inferior. Living room mostly looked good except the doorsill which needs refurbishment. In kitchen, cooking table, windows, illumination, ventilator were somewhat satisfactory but gas-warning device should have been installed. In addition, in bath room and toilet, location, door, window, illumination and finished material were satisfactory. But the stepped difference between the bath room and other space, safety-bar, emergency bell and floor heating system were seriously deteriorated and must be improved for the safety of the elderly. Conclusively, living environment of group-home for the elderly is mainly satisfactory but it was necessary to take a consideration for their safety.

Comparisons of Estimation Methods of Instantaneous Frequency and Examples of its Application to Beam, Engine Block, and Car Door Vibration (순간 진동수 추정 방법론의 비교와 외팔보, 엔진 블록 및 자동차 문 진동에 의 적용예)

  • 박연규;김양한
    • Journal of KSNVE
    • /
    • v.3 no.4
    • /
    • pp.341-352
    • /
    • 1993
  • Although a frequency analysis by FFT algorithm has been widely used in the vibration community, this approach has somewhat limited features when an analysist want to see the details of frequency trends because FFT shows only energy contents along frequencies. So the concept of instantaneous frequency that represents the dominant frequency component at each time needs to be introduced. In this paper, to get the instantaneous frequency, two methods are used. Methods using Hilbert transform and evolutionary spectrum are those. One of the problems of estimating instantaneous frequency using Hilbert transform is that it is normally very sensitive to signal to noise ratio(SNR) because of the differentiation. Moving window is applied on the estimation of instantaneous frequency, and instantaneous frequency histogram are used to handle this problem and proved to be very effective. Computer simulations for various signals have been done to understand the characteristics of instantaneous frequency. The usefulness of signal analysis using instantaneous frequency was tested by three simple experiments, which were engine experiment, beam experiment, and car door experiment. The instantaneous frequency analysis is found to be a useful technique to analyze the signals that have time varying frequencies.

  • PDF

Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea (국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발)

  • Bae, Minjung;Choi, Gyeongseok
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses (농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Choi, Jeong-Man;Seo, Hye-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

A Study on the Comparison of Simulation for Heat Loss According to the Installation of Windows for Openings in External Wall of One Side Corridor Type Apartments (편복도식 아파트에서 복도 외측 창호의 설치 유무에 따른 열손실 시뮬레이션 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • As energy becomes an important source of power for national competitive force, not only Government administrations but also private sectors are striving to save energy. The purpose of this study is to compare and evaluate energy consumption of the corridor with and without window when improving the energy environment by installing door and window on the open area of entrance for one-side corridor type apartment. The energy usage was examined through this improvement process and the energy consumption amount was compared and analyzed by simulation before and after the installation. It is desired for this study to contribute to the government's green remodeling project.