• 제목/요약/키워드: Wind power generating

검색결과 137건 처리시간 0.023초

다변풍속 적응형 Darrieus-Sauonius 초합 수직푹 풍력발전 시스템의 설계 (A design of vertical axis wind power generating system combined with Darrieus-Savonius for adaptation of variable wind speed)

  • 서영택;오철수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.185-192
    • /
    • 1996
  • This paper presents a design of vertical axis Darrieus wind turbine combine with Savonius for wind-power generating system to be adapted for variable wind speed. The wind turbine consists of two troposkien- and four Savonius-blades. Darrieus turbine is designed with diameter 9.4[m], chord length 380[mm], tip speed ratio 5. Savonius turbine is designed with diameter 1.8[m], height 2[m], tip speed ratio 0.95. The design of turbine is laid for the main data of rated wind speed 10[m/s], turbine speed 101.4[rpm]. The generating power is estimated to maximum power 20[kW], and this is converted to commercial power line by means of three phase synchronous generator-inverter system. Generating system is designed for operation on VSVF(variable speed variable frequency) condition and constant voltage system.

  • PDF

풍력발전용 계통연계 DFIG의 출력 해석 (Power Analysis of Grid Connected Doubly Fed Induction Generator for Wind Power Generating System)

  • 이현채;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.326-329
    • /
    • 1997
  • This paper deals with the generating power analysis of wound rotor induction generator according to the rotor excitation for use of DFIG (Doubly Fed Induction Generator) system in wind power generation as a part of renewable energy development. In this way, the generating power of wound rotor induction generator can be achieved for a wide range wind speed of supersynchronous and subsynchronous speed.

  • PDF

이중여자 유도기의 가변속 풍력발전 제어해석 (Analysis of variable wind power generating control system using Doubly Fed Induction Machine)

  • 김정웅;김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.567-570
    • /
    • 2002
  • In variable speed wind power generating system connected in power grid, how to capture the maximum wind energy is most important thing Using the doubly fed induction machine as a generator in wind power generating system, it is possible to control the bidirectional slip power between grid and rotor side. This means that we can control the generating power under subsynchronous speed. To verify the theoretical analysis, computer simulation results using Psim program are presented to support the discussion.

  • PDF

Improvement in Active Power Control Methods for a Wind Farm Based on Modified Wind Turbine Control in Danish Grid Codes

  • Sim, JunBo;Song, Il-Keun;Lee, Yongseung;Lee, Hak-Ju;Choi, Yun-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1438-1449
    • /
    • 2018
  • The importance of power system stability has been emphasized with an increase of wind energy penetration in the power system. Accordingly, the guarantee on various control capabilities, including active and reactive power control of wind farms, was regarded as the most important aspect for the connection to the grid. To control the wind farm active power, the wind farm controller was introduced. The wind farm controller decides the power set points for each wind turbine generating unit and each wind turbine generating unit controls its power according to the set points from the wind farm controller. Therefore, co-relationship between wind farm controller and wind turbine controllers are significantly important. This paper proposes some control methods of wind farm active power control based on modified wind turbine control for power system stability and structures to connect wind turbine controllers to wind farm controller. Besides, this paper contributes to development of control algorithm considering not only electrical components but also mechanical components. The proposed contributions were verified by full simulation including power electronics and turbulent wind speed. The scenario refers to the active power control regulations of the Eltra and Elkraft system in Denmark.

수직축 Darrieus 풍력발전 시스템의 설계에 관한 기초연구 (A Basic Study on the Desist of Vertical Axis Darrieus Turbine for Wind-Power Generating System)

  • 서영택;김기승;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.82-84
    • /
    • 1994
  • This paper presents a design of vertical axis Darrieus wind turbine for wind-power generating system. The wind turbine consists of two troposkien blades, diameter is 10m approximately, and chord length 380mm, tip ratio speed 4. The design of turbine is laid for the main data of rated wind speed 10m/s, turbine speed 78rpm, the generating power is estimated to 25kW, and this is contorted to commercial power line by means of three phase synchronous generator-inverter system.

  • PDF

풍력발전용 권선형 유도발전기의 회전자 여자주파수를 이용한 속도와 출력제어 (A Speed and Power Control of DFIG Using the Exciting Frequency for Wind Power Generating)

  • 이우석;오철수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.349-356
    • /
    • 1999
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed and power control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. For the speed control analysis, torque simulation is performed whereby the different slip between operating motor driving frequency and synchronous frequency of M-G system applied. To keep the output rating of the generator, the exciting frequency and voltage attenuation are applied.

  • PDF

풍력발전을 위한 권선형 유도발전기의 역률제어 (Power Factor Control of Wound Rotor Inductiion Generator for Wind Power Generation)

  • 김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.6-9
    • /
    • 2000
  • In wind power generating system connected in power grid the value of stator flux has almost constant because the stator side of wound rotor induction generator is connected to power grid. Using the stator and rotor current it is possible to achieve control of generating power in stator side. This means that we can control the power factor by decoupled rotor current in synchronously rotating reference frame. To verify the theoretical analysis results of computer simulation and experiment are presented to support the discussion.

  • PDF

Energy Yield, Power Quality and Grid Integration of Wind Energy Converters

  • Hanitsch R. E.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.97-102
    • /
    • 2005
  • Because of the limited fossil resources and the need to avoid emissions and toxic waste the future energy supply will be based on a large portion of renewable energies: wind-, solar-, biomass- and geothermal energy. Focus is on the utilization of wind energy coming from onshore- and offshore-sites. Generating electricity from wind is state of the art and feeding large amounts of wind power into the electrical grid will create some additional problems. Suggestions concerning energy storage will be made and the problem of power quality is discussed.

Generation Scheduling with Large-Scale Wind Farms using Grey Wolf Optimization

  • Saravanan, R.;Subramanian, S.;Dharmalingam, V.;Ganesan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1348-1356
    • /
    • 2017
  • Integration of wind generators with the conventional power plants will raise operational challenges to the electric power utilities due to the uncertainty of wind availability. Thus, the Generation Scheduling (GS) among the online generating units has become crucial. This process can be formulated mathematically as an optimization problem. The GS problem of wind integrated power system is inherently complex because the formulation involves non-linear operational characteristics of generating units, system and operational constraints. As the robust tool is viable to address the chosen problem, the modern bio-inspired algorithm namely, Grey Wolf Optimization (GWO) algorithm is chosen as the main optimization tool. The intended algorithm is implemented on the standard test systems and the attained numerical results are compared with the earlier reports. The comparison clearly indicates the intended tool is robust and a promising alternative for solving GS problems.

배전계통에 연계된 풍력발전기 운영특성 분석 (Power Quality Analysis of Wind Power System interconnected with Distribution Networks)

  • 김현한;김광호;전정표;옥연호;곽희진;장진승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1338-1339
    • /
    • 2011
  • Recently the wind turbine generating systems are increasing world widely. This type of systems will change the nation's energy environment which largely depends on the fossil fuels. It will also bring new problems to the power industry and the customers. The expected problem is the voltage and frequency stability of the power distribution network, when a wind turbine generating system is connected to the line. It becomes necessary and important to evaluate their impact on the electrical network stability. This paper shows the electrical data measurement and analysis of a inductive wind turbine generator affecting the power quality problem of the distribution line.

  • PDF