A Study on the theory and cases of Constructability for Building Projects -With Case Study Application in Japan- (건설공사의 Constructability 이론과 적용사례에 관한 연구 - 일본의 사례연구를 중심으로 -)

  • Kim, Jin-Ho;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.157-164
    • /
    • 2002
  • In this study, attempts to analyze the case study of production design were carried out through: 1) exploration of the factors influencing the interface between architectural and production design phases; 2)application of precast technologies. Building design and construction planning in Japan may be characterized by ample use of Production Design which extends over the whole projects phases. Taking a composite construction system for apartment buildings which allow for alternative combination of different technologies as a case study object, three projects have been chosen to analyze actual process of determining product sub-system and their specification. And the expectancies of this paper are that it can be used as efficient data for improvement of system to systematize Constructability(Buildability) in korea.

A BIM-based Design Method for Energy-Efficient Housing (BIM 기반의 저에너지 주거공간 설계 기법 연구)

  • Yoon, Seung-Hyun;Park, Nam-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.187-192
    • /
    • 2009
  • Nowadays, global warming and high oil prices were a threat to the survival of the whole human race. One of a solution to respond to these problems is to reduce energy consumption of building. By adopting energy-saving design, the dissemination of low energy building is required. Therefore, to improve energy efficiency while reducing the usage of the design method is necessary to study actively. BIM-based systems applied to buildings, scheduled to be built by reducing the amount of energy reduction technologies can be analyzed. Depending on various design and equipment to set energy savings goals, you can select an alternative. If it is possible to predict the energy efficiency from the initial stage of design and support designing low energy building, we would be able to expect improvement in the economics of housing due to the reduction of energy consumption.

  • PDF

Considerations in the early stage of Designing the Unit Modular Building (유닛모듈러 건축물의 설계 초기 단계에서의 고려 사항)

  • Lee, Young-Ho;Lee, Du-Heon;Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.133-142
    • /
    • 2012
  • With the recent changes in building environments such as low-carbon green growth, there have been increasing demands for the new building system that is eco-friendly and can maximize efficiency such as the unit modular system. For the unit modular system, more than 80% of the whole process is carried out in the factory while in the field, mostly unit module assembling and finish work are done. Thus, the quality at the pre-construction stage when design and manufacturing are done determines the quality of the building as a whole. In the country, the unit modular method was first applied in 2003 to school buildings and has gradually expanded afterwards, but due to the lack of examples and related information as well as the small scale of modular manufacturers, its characteristics have not been sufficiently reflected in design, manufacturing and field constructions. This study, as an attempt to improve the design quality of unit modular buildings, points to the problem in manufacturing and field construction, compares and analyzes its causes, and suggests major points to be considered in the early stage of designing the unit modular buildings.

A Basic Study on the Development of a BIM-based Realtime Performance Evaluation Technology for the User Life Safety in the Buildings (건물 내의 사용자 생활안전설계를 위한 BIM기반 실시간 성능검토 기술개발에 관한 기초연구)

  • Lee, Yun Gil
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.9
    • /
    • pp.1058-1067
    • /
    • 2015
  • Dweller's safety is one of the most important factors for the evaluation of building performance. The process of conventional safety design which is normally performed by the codes and designer's experiences is not enough to check the whole possibilities of unexpected accidents in the built environment. It means that the dwellers might be always exposed by the dangerous situation which should have been removed in the architectural design process. In order to solve this problem, this study intends to introduce a rule-based performance evaluation technology based on BIM(Building Information Modeling). The proposed technology focuses on the real time evaluation of dweller's safety in the ordinary life in the designed building alternatives and uses a commercial BIM tool as a design and evaluation platform.

BUILDING INFORMATION MODELING (BIM)-BASED DESIGN OF ENERGY EFFICIENT BUILDINGS

  • Cho, Chung-Suk;Chen, Don;Woo, Sungkwon
    • Journal of KIBIM
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • With the increased awareness of energy consumption as well as the environmental impact of building operations, architects, designers and planners are required to place more consideration on sustainability and energy performance of the building. To ensure most of those considerations are reflected in the building performance, critical design decisions should be made by key stakeholders early during the design development stage. The application of BIM during building energy simulations has profoundly improved the energy analysis process and thus this approach has gained momentum. However, despite rapid advances in BIM-based processes, the question still remains how ordinary building stakeholders can perform energy performance analysis, which has previously been conducted predominantly by professionals, to maximize energy efficient building performance. To address this issue, we identified two leading building performance analysis software programs, Energy Plus and IES (IES ), and compared their effectiveness and suitability as BIM-based energy simulation tools. To facilitate this study, we examined a case study on Building Performance Model (BPM) of a single story building with one door, multiple windows on each wall, a slab and a roof. We focused particularly on building energy performance by differing building orientation and window sizes and compared how effectively these two software programs analyzed the performance. We also looked at typical decision-making processes implementing building energy simulation program during the early design stages in the U.S. Finally, conclusions were drawn as to how to conduct BIM-based building energy performance evaluations more efficiently. Suggestions for further avenues of research are also made.

A Study on Information of the Green building Design for friendly environment (환경 친화를 위한 그린빌딩 디자인 정보에 관한 연구)

  • 강승모;김수정;권자인
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.26-33
    • /
    • 2000
  • The end of the 20th century, on the ecological world-view which looks the whole things as systematic and admits the incessant change, human is considered to function with the environment mutually and to evolve in harmony with it. Because of the living style of the modern people whose most time spent inside of the buildings, eco-office elements are introduced in the inteior places where many general publics are gathered. We gather up the all information about Eco-office, introduction of green building certification system, Eco-office System Technics and provide source to how to design interact with eco-office.

  • PDF

An Economic Analysis of Irregular Wall Design Considering Effective Width (벽체의 유효폭을 고려한 이형벽체의 경제성 분석)

  • Han, Kyung-Soo;Bang, Jung-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.83-84
    • /
    • 2014
  • The whole wall system behaves as one section because single walls composing irregular wall are connected to each other. Although stress of a single wall is affected to the connected wall under lateral load, the stress is not transferred to whole sections and is concentrated on particular part of the wall as well. Therefore these walls can be divided into the effective and ineffective section. The purpose of this study is to compare design result of irregular wall using codes and previous studies on an effective width of the wall and to analyze reduction of the longitudinal bar of irregular wall.

  • PDF

Structural Design of Cheongna City Tower

  • Chung, Kwangryang;Kim, Jung-Hyun;Song, Younghoon;Kim, Sihyeong;Kang, Jihun
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.193-201
    • /
    • 2021
  • Cheongna City Tower is a 448-meter-high rise observatory tower with 8.7:1 aspect ratio located at central lake park in Incheon Cheongna international city. The tower is a crystal shaped image and it turns invisible when the façade is activated. The tower was planned to be hexagonal 30-story building with two basements which are composed of mega frame structure using mega column and mega brace. In order to minimize the wind effect, the blow-through area was installed so that the wind can pass through. This observatory tower is an unprecedented project since the whole building is covered by façade for invisibility effect.

Analysis on Green BIM based Atrium Sizes in the Early Design Stage

  • Jeong, Seung-Woo;Lee, Kweon-Hyoyng;Choo, Seung-Yeon
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.260-266
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance according to the types of atrium of office building. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was understood, and the followings are the considerations for designing an atrium. First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning an atria within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

  • PDF

Development of Internet based Ship Technical Information Management System (인터넷 기반의 선박 기술정보 관리시스템 개발)

  • Lee S.-S.;Lee J.-K.;Park B. J,;Kim S.-Y.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.2
    • /
    • pp.89-96
    • /
    • 2005
  • In this paper, Internet based ship technical information management system has been developed as a means to accumulate, manage, share and utilize various distributed applications and information used for ship design and building. The information managed in the system are data from whole life cycle including concept design, basic design, detailed design, construction, operation and maintenance. In addition, using the developed system, integrated system framework is also proposed to integrate applications and database in concurrent engineering environment.