• 제목/요약/키워드: Wet bar

검색결과 51건 처리시간 0.026초

KOH계열 수용액을 이용한 GaN 박막의 photo-assisted 식각 특성 (Photo-assisted GaN wet-chemical Etching using KOH based solution)

  • 이형진;송홍주;최홍구;하민우;노정현;이준호;박정호;한철구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.339-339
    • /
    • 2010
  • Photo-assisted wet chemical etching of GaN thin film was studied using KOH based solutions. A $2{\mu}m-2{\mu}m$ titanium line-and-space pattern was used as a etching mask. It is found that the etching characteristics of the GaN thin film is strongly dependent on the pattern direction by unisotropic property of KOH based solution. When the pattern was aligned to the [$11\bar{2}0$] directions, ($10\bar{1}n$)-facet is revealed constructing V-shaped sidewalls.

  • PDF

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.

균일촉매를 이용한 페놀의 습식산화 (Wet Oxidation of Phenol with Homogeneous Catalysts)

  • 서일순;류승훈;윤왕래
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.292-302
    • /
    • 2009
  • 페놀 습식산화에 미치는 반응온도($150{\sim}250^{\circ}C$), 산소분압(25.8~75.0 bar) 및 초기 pH(1.0~12.0)의 영향을 10 g/l의 페놀 초기농도를 사용하여 조사하였다. 습식산화속도는 화학적 산소요구량 COD를 이용하여 산출하였으며 반응 중간 생성물들을 고성능액체크로마토그래피를 사용하여 측정하였다. 습식산화 중 페놀 분해속도는 페놀에 대하여 1차 반응차수를 나타냈으며, COD 변화는 lumped 모델로 잘 묘사할 수 있었다. 금속이온($Cu^{2+}$, $Fe^{2+}$, $Zn^{2+}$, $Co^{2+}$, $Ce^{3+}$) 균일촉매의 습식산화 중 페놀 분해속도 및 COD 제거속도에 미치는 영향도 조사하였다. 페놀 분해속도 및 COD 제거속도는 $CuSO_4$를 사용한 촉매습식산화에서 가장 크게 나타났으며 촉매농도를 증가시킴에 따라 증가하였다. 습식산화 중 생성되는 개미산의 분해속도는 반응온도 및 $CuSO_4$ 농도를 증가시킴에 따라 증가하였다. 난분해성 생성물 초산의 최종농도는 반응온도를 증가시킴에 따라 증가하였으나 $CuSO_4$ 농도를 증가시킴에 따라 감소하였다.

The Effect of Pretreatment for Cemented Carbide Substrate Using Wet Blasting

  • Hong, Sung-Pill;Kim, Soo-Hyun;Kang, Jae-Hoon;Yoon, Yeo-Kyun;Kim, Hak-Kyu
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1102-1103
    • /
    • 2006
  • The pretreatment for substrate was carried out in change of gun pressure of $0.5\sim3.5$ bar using wet blasting. The size of $Al_2O_3$ powder was about $50{\sim}150{\mu}m$. As the results, the surface roughness of cemented carbide substrate was improved with increment of gun pressure of wet blasting. A new surface layer was formed and Co particles were uniformly distributed over the entire surface after pretreatment. The adhesion of the pretreated substrate in same PVD-TiAlN film was improved and in approximately $Ra=90\sim120\;nm$ shown the best adhesion value.

  • PDF

흡습된 수냉각 발전기 고정자 권선의 전기적 특성 (Electrical Properties of Wet Bars in Water-cooled Generator Stator Windings)

  • 김병래;김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.817-823
    • /
    • 2012
  • Insulation breakdown of water-cooled generator stator windings occurs frequently due to leakage of cooling water and absorption into the insulation material. Leakage and absorption problems of water-cooled stator windings are often found during regular preventive maintenance. To evaluate cooling water leakage and absorption, diagnostic tests were performed on two water-cooled turbine generators, which have been in service for 13 and 17 years, respectively. The test results of the measured electrical properties such as dissipation factor($tan{\delta}$), capacitance and AC leakage current for water-cooled generator stator windings with wet bars are reported in this paper.

Carbon bead-supported copper-dispersed carbon nanofibers: An efficient catalyst for wet air oxidation of industrial wastewater in a recycle flow reactor

  • Yadav, Ashish;Verma, Nishith
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제67권
    • /
    • pp.448-460
    • /
    • 2018
  • Copper nanoparticle-doped and graphitic carbon nanofibers-covered porous carbon beads were used as an efficient catalyst for treating synthetic phenolic water by catalytic wet air oxidation (CWAO) in a packed bed reactor over 10-30 bar and $180-230^{\circ}C$, with air and water flowing co-currently. A mathematical model based on reaction kinetics assuming degradation in both heterogeneous and homogeneous phases was developed to predict reduction in chemical oxygen demand (COD) under a continuous operation with recycle. The catalyst and process also showed complete COD reduction (>99%) without leaching of Cu against a high COD (~120,000 mg/L) containing industrial wastewater.

Nylon FDY와 ROY로 제조한 ATY의 물성에 관한 연구 (A Study on the Physical Properties of ATY Produced with Nylon FDY and ROY)

  • 김승진;김재우;홍상기
    • 한국염색가공학회지
    • /
    • 제16권6호
    • /
    • pp.35-43
    • /
    • 2004
  • This study surveys the physical properties of ATY produced with FDY and POY. ATY is made with 70d Nylon FDY and 80d Nylon POY using AIKI air jet texturing machines, respectively. The processing parameters such as air pressure and yam speed are varied, and air pressure is varied ranging with 8.5bar, l0.5bar and 1l.5bar, and yarn speed is varied ranging with 400m/mim, 450m/mim, and 500m/min. The various physical properties of ATY made by POY and FDY denier, wet shrinkage, dry shrinkage, tensile properties, thermal stress and instability are measured and discussed with air pressure and yam speed. The shrinkage simulation of ATY is performed for analysing the process shrinkage on the dyeing and finishing processes.

메탄올 수증기개질을 위한 ZrO2 펠트 기반 Cu/Zn 촉매 특성 연구 (Characteristics of ZrO2 Felt Supported Cu/Zn Catalyst for Methanol Steam Reforming)

  • 최은영
    • 한국수소및신에너지학회논문집
    • /
    • 제28권2호
    • /
    • pp.129-136
    • /
    • 2017
  • Characteristics of $ZrO_2$ felt supported Cu/Zn catalysts have been investigated for the production of hydrogen via methanol steam reforming. Cu and Zn in different weight percent were loaded using wet impregnation over $ZrO_2$ felt support. The catalysts were characterized with BET and FE-SEM. The performance of these synthesized catalysts were investigated at SCR=1.5, $GHSV=2000h^{-1}$, temperature=$300{\sim}400^{\circ}C$, and pressure=2.5~19.5 barA. The results showed that the $Cu^{32.5}Zn^{7.5}ZrO_2$ catalyst was most active in terms of methanol conversion and hydrogen production. The methanol conversion in steam reforming of methanol was 84.6% at 19.5 barA and furnace $400^{\circ}C$ over $Cu^{32.5}Zn^{7.5}ZrO_2$ catalyst. The catalysts prepared using $ZrO_2$ felt show higher reactor temperature than the pellet type catalyst at same furnace temperature.

볼엔드밀을 이용한 고속가공에서 가공환경 변화에 따른 열특성 평가 (Evaluation of thermal characteristics by cutting environments in high speed ball end-milling)

  • 이채문
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.34-38
    • /
    • 2000
  • The trend of cutting process today goes toward higher precision and higher efficiency. Many thermal/frictional troubles occur in high-speed machining of die and mold steels.In this paper, the thermal characteristics are evaluated in high sped ball end-milling of hardened steel(HRc42). Experimental work is performed on the effect of cutting environments on tool life and cutting temperature. Cutting environments involve dry, wet(20bar), compressed chilly air at -9$^{\circ}C$, compressed chilly air at -35$^{\circ}C$. The measuring technique of cutting temperature using implanted thermocouple is used. The cutting temperature is about 79$0^{\circ}C$, 35$0^{\circ}C$ and 54$0^{\circ}C$ in dry, wet and compressed chilly air at +9$^{\circ}C$, respectively. The tool life for compressed chilly air at -9$^{\circ}C$ is longer than all other cutting environments in experiment.

  • PDF

고강도콘크리트 내화성능을 확보한 건식화 PFB 공법 개발에 관한 연구 (A Study on the Development of a Dry PFB Method with High Fire Resistance)

  • 김우재;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.49-52
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire-resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire-resistant boards. 1. Improved PF board was prepared by adding inorganic fiber to existing board and using aggregate with grain size of 3mm or less. Molding was done at temperature higher than that for existing PF board molding. While wet curing is used for existing PF boards, this study used dry curing in order to enhance heat insulation performance. 2. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116℃ in 15mm, 103.8℃ in 20mm, and 94℃ in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3-hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF