• Title/Summary/Keyword: Weighing

Search Result 1,640, Processing Time 0.029 seconds

Quality Assesment of Domestic Nonautomatic Weighing Instruments by International Standards (국제기준에 의한 국내 비자동저울의 품질 평가에 관한 연구)

  • 김홍원;남궁재관;김창열;공재향
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.263-268
    • /
    • 2004
  • This study is to improve the quality of electronic weighing machine by providing a reformation plan on currently problems of domestic manufactured nonautomatic weighing instruments, and by test items and criteria considering internal situation on base of identification of quality level of domestic manufactures electronic weighing machine according to the international standards.

  • PDF

Analysis of Performance comparision of nonautomatic weighing instruments (비자동저울의 성능비교 분석에 관한 연구)

  • 남궁재관;김홍원;공재향
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.3-8
    • /
    • 2003
  • This study is to improve the quality of electronic weighing machine by providing a reformation plan on currently problems of domestic manufactured nonautomatic weighing instruments, and by test items and criteria considering internal situation, on base of identification of quality level of domestic manufactures electronic weighing machine according to the international standards.

  • PDF

Development and Evaluation of an Inexpensive Weighing Chamber for Particulate Filters (미세먼지 여지의 무게 측정을 위한 저비용 계량챔버 개발 및 성능평가)

  • Jun-Hyun Park;Ho-Jin Lim
    • Journal of Environmental Science International
    • /
    • v.32 no.2
    • /
    • pp.131-137
    • /
    • 2023
  • Filter and microbalance sensitivity in measuring fine particulate matter mass is greatly influenced by particulate properties and environmental factors. Temperature and humidity control inside a measuring chamber with a microbalance, and neutralization of static charges on filters are essential for consistent filter weighing. Commercial weighing chambers are expensive with a unit price of tens of millions won. This study developed an inexpensive weighing chamber for weighing fine particulate matter and evaluatedits weighing performance. A microbalance with 1 ㎍ precision was used to measure the weight of a filter. The microbalance was set in a transparent acrylic enclosure (100 × 60 × 65 cm3) equipped with temperature and humidity control equipments. Weighing performance of the chamber was examined using Teflon filters with or without different particulate sample types. Temperature and humidity were maintained at approximately 23.2±1.2 ℃ and 36.2±1.8℃ for 8 days, respectively.

A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge (자동 저수와 배수가 가능한 중량 우량계 용 쌍수조)

  • Lim, Gyu-Ho;Lim, Eun Ok
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

Effects of Changing Weighing Factor in a Two Stage Shrinkage Testimator for the Mean of an Exponential Distributions

  • Myung-Sang Moon
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.3
    • /
    • pp.895-904
    • /
    • 1998
  • Two stage shrinkage testimator is a kind of adaptive estimators based on a test on an initial estimate of parameter. Since weighing factor plays an important roll in assessing the properties of testimator, its choice is extremely crucial in two stage testimation. Adke, Waikar and Schuurmann(1987) proposed a testimator for the mean of an exponential distribution defined with their own weighing factor. Two alternative testimators obtained using changed weighing factors are presented, and their Mean squared error(MSE) formulae are provided in this paper. Their properties are compared with those of existing one by means of MSE.

  • PDF

A-OPTIMAL CHEMICAL BALANCE WEIGHING DESIGN WITH CORRELATED ERRORS

  • Ceranka, Bronislaw;Graczyk, Malgorzata
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.143-150
    • /
    • 2004
  • In this paper we study the estimation problem of individual weights of objects using an A-optimal chemical balance weighing design. We assume that in this model errors are correlated and they have the same variances. The lower bound of tr$(X'G^{-1}X)^{-1}$ is obtained and a necessary and sufficient condition for this lower bound to be attained is given. There is given new construction method of A-optimal chemical balance weighing design.

Development of a Automated Noncontact Weighing System for Pigs (돼지의 자동 비접촉 체중계측 시스템 개발)

  • 임영일
    • Journal of Animal Environmental Science
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2000
  • A automated noncontact weight system for pigs consisted of a CCD-type video camera and 10 photo sensors connected to a computer. In the experiment 20 pigs(Large Yorkshire $\times$ Landrace breed) weighing from 95kg to 115kg were used. Pig's original image data was transformed to a binary image an image excluding head and tail portion from the whole binary image and the area of pig was calculated. Then pig's volume was calculated by multiplying the area by the body hight measured with photo sensors. The correlation equation between the above volume(x) and pig's weight was y=0.0007 x -9.2152($R^2$=0.9965) Performance of a automated noncontact weighing system for pigs was tested with this equation. The results showed $\pm$0.65kg average error and 1.63kg maximum error. It was concluded that performance of a automated noncontact weighing system is excellent.

  • PDF

A study on the development of dynamic weighing measurement system (동하중 측정 신호처리의 개발에 관한 연구)

  • Park, Chan-Won;Shin, Hyoung-Jae;Lee, Young-Jun;Shin, Young-kyun;Ann, Kwang-Hee
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.173-180
    • /
    • 1998
  • A high speed and stable A/D conversion data process is required to weigh a mass on moving conveyer weighing platter. The paper presents a new method to obtain stable and fast automatic weighing A/D conversion data process. Dynamic weighting system which is constructed with dual load cell is realized by the stable A/D conversion data process algorithm using DSP. The proposed method is applied to the real design, and that experimental results showed good performances of the weighing stability.

  • PDF

Comparison of Dietary Methods in Nutritional Studies (식사섭취조사방법의 비교연구)

  • 김혜경
    • Journal of Nutrition and Health
    • /
    • v.22 no.1
    • /
    • pp.23-31
    • /
    • 1989
  • The purpose of this study was to evaluate the validity of various dietary methods. Dietary intake of 24 patients on regular diet was investigated by three methods. One method was a precise weighing method, the others were 24-hour dietary recall method and convenient dietary questionnaries. The results obtained are summarized as followes ; 1) There were no significant differences in mean nutrient intake of subjects among three dietary survey methods. 2) The validity coefficient between the precise weighing method and 24-hour recall method, ranging from 0.26(fat) to 0.59(carbohydrate) showed significant correlation for carbohydrate, vitamin A, thiamin, riboflavin and ascorbic and intakes. 3) The validity coefficient between precise weighting method and covenient dietary questionnaires, ranging from 0.14(fat) to 0.80(vitamin A), showed a significant correlation for most nutrients. 4) Female showed higher correlation between the precise weighing method and 24-hour recall method than male subjects for most nutrients. However, there was no significant sexual difference of correlation between weighing method and convenient method. 5) The correlation coefficient between the precise weighing method and the other two methods by age group showed younger sujbects have a higher significant correlation than older subjects for most nutrients.

  • PDF

Improvement of Uncertainty for Gravimetric Flow Calibrator (10톤 용량의 중량식 교정장치에 대한 불확도 개선)

  • Lee, Dong-Keun;Park, Joo-Young;Lee, Haeng-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1042-1046
    • /
    • 2008
  • Both the weighing bridge and the diverter system is a important component in achieving a high accuracy liquid flow rate standard using a static gravimetric method. The weighing bridge is a tank which weighing collected flow with a load cells. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that the measurement deviation of load cell and uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

  • PDF