3-D finite Element Analysis for Thermo-Mechanical Behavior of Laminated Carbon-Phenolic Composite Ring for Rocket Nozzle Insulator (로켓 노즐 내열부품용 탄소-페놀 복합재 적층링의 열기계적 거동에 대한 3차원 유한요소 해석)

  • Lee, Sun-Pyo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, the thermal insulator structure of a real rocket which is fabricated in a way that laminated composite rings are connected in series is analyzed using 3-dimensional axisymmetric finite element models. Simulation of cowl zone using a real operating conditions provides that the stress distribution in the laminated composite ring is largely influenced by ply-angles, axial dimensions, and boundary conditions. Notably the plylift that is the precursor to the wedge-out occurs in the ring-to-ring bonding region. It is hypothesized that after the plylift the wedge is dropped out due to the shear stresses in the ply-angle direction and axial compressive stresses.

An Estimation of Behavior for Wedge type Removable Soil Nailing System by Field Trial Construction (현장시험시공을 통한 쐐기형 제거식 쏘일네일링 공법의 거동 평가)

  • Han, Yeon-Jin;Park, Si-Sam;Kwon, Hyuk-Jun;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1360-1364
    • /
    • 2009
  • Necessity of removable soil nailing has been arisen in the soil nailing system because of problem such as civil petition for geotechnical environment and invasion of the ground boundary line and payments for use besides geotechnical engineering. Removable soil nailing system is improved soil nailing system that fixed socket arranged in boring hole for increasement of skin friction. In this study, field pull-out tests are carried out more 4 times considering installed distance of fixed socket and analyze skin friction behavior characteristics in fixed socket through analysis of measurements of strain gauge attached to fixed socket. Also, to evaluate application for wedge type removable soil nailing system analyzing displacement aspects through field pull-out tests by trial construction.

  • PDF

A Study on the Wedge Angle of the Rail Clamp according to the Change of the Design Wind Speed Criteria (설계풍속 상향조정에 따른 레일클램프의 쐐기각에 대한 연구)

  • Lee, Jung-Myung;Han, Dong-Seop;Lee, Seong-Wook;Shim, Jae-Joon;Han, Geun-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.12 s.189
    • /
    • pp.103-110
    • /
    • 2006
  • The rail clamp is very important device to prevent that a container crane slips along a rail due to the wind blast as well as to locate the crane in the set position during an operating mode. Recently, the design wind speed criteria were intensified from the wind speed of 16m/s to 35m/s during an operating mode, and from 50m/s to 75m/s during a stowed mode in Korea, according to the 'Inspection Criteria for Facilities and Equipments in Port' reformed after typhoon 'Maemi'. In order to design the wedge type rail clamp for the reinforced design wind speed criteria of 35m/s, we carried out the finite element analysis of the rail clamp with respect to the wedge angle, and analyzed the relationship between the wedge angle and the sliding distance of the rail clamp.

Characteristics of Roadside Cut-Slopes Failures along the 46th National Highway (남양주-춘천(국도 46 호선)간 도로절개면 붕괴 특성 고찰)

  • 구호본;정의진;박성욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.527-534
    • /
    • 2000
  • 136 cut slopes which extends from Namyangju to Chunchon city along the 46th national highway were investigated to analyze the influence factors affecting slope instability. Geologic and geotechnical conditions were examined and the detailed investigation were carried out for fifty five failed slopes. failure mode (wedge failure, planar failure, circular failure, sheet eroison and rock falls) are examined with respect to slope inclination, rock type, weathering grade and discontinuity patterns. It is suggested that the failure modes and their dimensions have relations to the morphology and geologic conditions of the slopes. Wedge failure has highest is the most frequent failure mode and falls, sheet erosions, planar failures and circular in descending order of failure percentage. Wedge failure is most dominant failure type over all lithology except quartzite formation. In slopes of well foliated and banded gneiss, failure ratio of wedge is up to 50% ca. Failure ratio(number of rock fall/number of total failure) of rock fall increases with increase fo slope inclinations and decrease of weathering grade. Dimension analyses of failed slopes shows wedge and circular failure has higher value of D/L and D/H than planar failure and sheet erosion.

  • PDF

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Relationship between the Initial Clamping Force and the Proper Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 적정위치사이의 관계)

  • Han, Dong-Seop;Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.357-362
    • /
    • 2006
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases because of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the proper position of supporter in the wedge type rail clamp.

  • PDF

Relationship between the Initial Clamping Force and the Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 위치사이의 관계)

  • Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon;Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.65-70
    • /
    • 2007
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases bemuse of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the position of supporter in the wedge type rail clamp.

Experimental Study on the Compressive Behavior of Horizontal Joint in Precast Concrete Large Panel Structure (P.C. 대형판 구조의 수평접합부 압축거동에 관한 실험적 연구)

  • 조양호;이한선;김현산
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.19-24
    • /
    • 1994
  • Four types of horizontal joint were tested to investigate the difference with regards to the compressive behavior and strength. These include wedge-type joints (i)with and (ii)without transverse reinforcement against splitting failure of the panel concrete, and wedge-type joints (iii)with different widths of joint concrete (6cm vs 8cm) and (iv)closed platform joint. It was shown that the compressive strength of wedge-type joint is about 10% higher than that of closed-type (platform) joint. But the effect of transverse reinforcement and joint concrete widths on the strength of the joints turned out be negligible. Also, the moduli of elasticity in panel and joint are compared and the equivalent moduli of the whole wall are derived.

  • PDF

Study on a loading mechanism for fixed ratio traction drives (고정 감속비트랙션 드라이브의 압부력 발생장치에 대한 연구)

  • Kim, Sung-Yeol;Kim, Bae-Jin;Park, Dae-Hyun;Oh, Se-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1212-1218
    • /
    • 2003
  • A novel loading mechanism of wedge roller type has been developed. This type traction drive has long system life and high efficiency by changing the pre-load on a contact point. And this loading mechanism does not need precision machining. So it has, as opposed to the conventional loading mechanism, an advantage in saving manufacturing cost. In this paper, by analyzing pre-load generating mechanism, spring pre-load and the roller size are defined and the stress on the contact point by pre-load is calculated. On the basis of this analysis, the model of wedge roller type traction drive for the test is made and was carried out its performance test. It can transmit input torque up to 1.5 N m, with high efficiency over 91% up to 98%, with slip rate under 2.5%.

  • PDF

NON LINEAR VARIABLE VISCOSITY ON MHD MIXED CONVECTION HEAT TRANSFER ALONG HIEMENZ FLOW OVER A THERMALLY STRATIFIED POROUS WEDGE

  • Kandasamy, R.;Hashim, I.;Ruhaila, K.
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.1_2
    • /
    • pp.161-176
    • /
    • 2008
  • The effect of variable viscosity on MHD mixed convection Hiemenz flow over a thermally stratified porous wedge plate has been studied in the presence of suction or injection. The wall of the wedge is embedded in a uniform Darcian porous medium in order to allow for possible fluid wall suction or injection and has a power-law variation of the wall temperature. An approximate numerical solution for the steady laminar boundary-layer flow over a wall of the wedge in the presence of thermal diffusion has been obtained by solving the governing equations using numerical technique. The fluid is assumed to be viscous and incompressible. Numerical calculations are carried out for different values of dimensionless parameters and an analysis of the results obtained shows that the flow field is influenced appreciably by the magnetic effect, variable viscosity, thermal stratification and suction / injection at wall surface. Effects of these major parameters on the transport behaviors are investigated methodically and typical results are illustrated to reveal the tendency of the solutions. Comparisons with previously published works are performed and excellent agreement between the results is obtained.

  • PDF