• Title/Summary/Keyword: Wedge Angle

Search Result 232, Processing Time 0.037 seconds

The Effect of Derotational Closing Wedge Akin Osteotomy for the Treatment of Hallux Valgus with the Pronation of Great Toe (무지의 회내 변형을 동반한 무지 외반증에서 폐쇄적 회외감염 Akin 절골술의 효과)

  • Moon, Gi-Hyuk;Ahn, Gil-Yeong;Lee, Yeong-Hyun;Nam, Il-Hyun;Lee, Jung-Ick
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.14-19
    • /
    • 2008
  • Purpose: We tried to understand the effects of the derotational closing wedge Akin osteotomy during the operation for the hallux valgus with pronation of great toe. Materials and Methods: Eighty five patients who had undergone Akin osteotomy among the eighty seven patients who had been treated with Scarf osteotomy with hallux valgus were included in this study. Derotational supination was added on the medial closing wedge Akin osteotomy at the base of proximal phalanx and it was secured with K-wire, headless screw or staple. We measured and analyzed pre- and post-operative hallux primus valgus angle and hallux pronational rotatory angle. Results: The hallux primus valgus angle improved an average of $14{\pm}2.98$ degrees to $-1{\pm}1.68$ degrees with the hallux pronational rotatory angle respectively from $24.8{\pm}7.64$ degrees to $4.7{\pm}4.22$ degrees. Conclusions: After the metatarsal osteotomy for the treatment of the hallux valgus with the pronation of great toe, derotational closing wedge Akin osteotomy can give us a belief that it can correct the hallux primus valgus angle and hallux pronational rotatory angle also and it can be a helpful method for minimizing the recurrence rate of the hallux valgus deformity.

  • PDF

Load analysis of Wedge type Rail Clamp (쐐기형 Rail Clamp의 하중분석)

  • Han, Geun-Jo;Ahn, Chan-Woo;Kim, Tae-Hyong;Shim, Jae-Joon;Han, Dong-Seop;Lee, Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1-6
    • /
    • 2003
  • In this paper, we design a wedge type rail clamp which can protect container crane from wind with constant clamping force regardless of the operating period. When we design wedge type rail clamp. it is important to determine the angle of wedge and analyze a contact condition of roller and wedge so that we might develop a rail clamp with variable capacity. Therefore, this paper suggest a process to decide wedge angles within feasible range which could be obtained using load analysis and FEA of wedge type rail clamp.

  • PDF

A Comparison of Operative Treatment of Hallux Valgus with a Proximal Metatarsal Osteotomy and with a Modified Chevron Osteotomy (근위 중족골 절골술과 변형 chevron 절골술을 이용한 무지 외반증의 수술적 치료의 비교)

  • Choi, Jae-Yeol;Shin, Hun-Kyu;Kim, Young-Hun;Kim, Hong-Kyun;Lee, Ho-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 2004
  • Purpose: We compared the result of a proximal metatarsal closed wedge osteotomy and soft tissue procedure with a modified chevron osteotomy and soft tissue procedure in the treatment of hallux valgus. Materials and Methods: Between March 1999 and February 2003, we performed proximal metatarsal closed wedge osteotomy and soft tissue procedure on 17 feet (12 patients), and modified chevron osteotomy and soft tissue procedure on 12 feet (9 patients). Results: According to Mayo clinic forefoot scoring system (FFSS), group 1, with proximal metatarsal closed wedge osteotomy, shows 67.2 points postoperatively and group 2, with modified chevron osteotomy, shows 68.5 points postoperatively. In group 1, the average correction of hallux valgus angle and intermetatarsal angle was 20.8 degrees and 4.8 degrees, respectively. In group 2, the average correction of hallux valgus angle and intermetatarsal angle was 19.9 degrees and 4.7 degrees, respectively. The average shortening was 3.15 mm in group 1 and 1.38 mm in group 2. Conclusion: We obtained relatively good clinical and radiographic result in this study. The effect on shortening of the first metatarsal was greater in the proximal metatarsal closed wedge osteotomy than modified chevron osteotomy, but the metatarsal shortening did not related with metatarsalgia. So, both techniques seems optimal surgical treatment for hallux valgus deformity.

  • PDF

The Experimental Study on the Collapse Mechanism of CFRP Composite Tubes (CFRP 복합재 튜브의 압괴메카니즘에 관한 실험적 연구)

  • 김영남;차천석;양인영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.149-157
    • /
    • 2002
  • This paper is to investigate collapse mechanisms of CFRP(Carbon Fiber Reinforced Plastics)composite tubes and to evaluate collapse characteristics on the change of interlaiminar number and ply orientation angle of outer under static and impact axial compression loads. When a CFRP composite tube is crushed, static/impact energy is consumed by friction between the loading plate and the splayed fronds of the tube, by fracture of the fibers, matrix and their interface. These are associated with the energy absorption capability. In general, CFRP tube with 6 interlaminar number(C-type), absorbed more energy than other tubes(A, B, D-types). The maximum collapse load seemed to increase as the interlaminar number of such tubes increases. The collapse mode depended upon orientation angle of outer of CFRP tubes and loading status(static/impact). Typical collapse modes of CFRP tubes are wedge collapse mode, splaying collapse mode and fragmentation collapse mode. The wedge collapse mode was shown in case of CFRP tubes with 0° orientation angle of outer under static and impact loadings. The splaying collapse mode was shown in only case of CFRP tubes with 90°orientation angle of outer under static loadings, however in Impact tests those were collapsed in fragmentation mode .

Wedge Shape Cage in Posterior Lumbar Interbody Fusion : Focusing on Changes of Lordotic Curve

  • Kim, Joon-Seok;Oh, Seong-Hoon;Kim, Sung-Bum;Yi, Hyeong-Joong;Ko, Yong;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.255-258
    • /
    • 2005
  • Objective : Lumbar lordotic curve on L4 to S1 level is important in maintaining spinal sagittal alignment. Although there has been no definite report in lordotic value, loss of lumbar lordotic curve may lead to pathologic change especially in degenerative lumbar disease. This study examines the changes of lumbar lordotic curve after posterior lumbar interbody fusion with wedge shape cage. Methods : We studied 45patients who had undergone posterior lumbar interbody fusion with wedge shape cage and screw fixation due to degenerative lumbar disease. Preoperative and postoperative lateral radiographs were taken and one independent observer measured the change of lordotic curve and height of intervertebral space where cages were placed. Segmental lordotic curve angle was measured by Cobb method. Height of intervertebral space was measured by averaging the sum of anterior, posterior, and midpoint interbody distance. Clinical outcome was assessed on Prolo scale at 1month of postoperative period. Results : Nineteen paired wedge shape cages were placed on L4-5 level and 6 paired same cages were inserted on L5-S1 level. Among them, 18patients showed increased segmental lordotic curve angle. Mean increased segmental lordotic curve angle after placing the wedge shape cages was $1.96^{\circ}$. Mean increased disc height was 3.21mm. No cases showed retropulsion of cage. The clinical success rate on Prolo's scale was 92.0%. Conclusion : Posterior lumbar interbody fusion with wedge shape cage provides increased lordotic curve, increased height of intervertebral space, and satisfactory clinical outcome in a short-term period.

The Effects of Femorotibial Angle of a Contact Lateral-Wedged Insole with Strapping in Patients with Varus Deformity Osteoarthritis of the Knee (밀착성 외측 쐐기 스트랩 깔창이 내반슬 골관절염 환자의 대퇴경골각에 미치는 영향)

  • Lee, Sang-Yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose are to assess the efficacy of a contact lateral-wedged insole with strapping on the femorotibial angle in patients with varus deformity osteoarthritis of the knee after treatment period. 25 outpatients with knee osteoarthritis (OA) were randomized to be treated with a contact lateral-wedge insole with strapping. Standing radiographs were used to analyze the femorotibial angle for each subject. The result of repeated two-way ANOVA's reveled that a contact lateral-wedged insole with strapping produced significantly differences in the femorotibial angle between groups after treatment period (P<0.05). and repeated one-way ANOVA's reveled that it produced significantly differences in the femorotibial angle between experimental groups after treatment period (P<0.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and later compartment forces in the knee varus-valgus deformity.

  • PDF

Behaviors of Anisotropic Fluids in the Vicinity of a Wedge

  • Kim, Youn-J.
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.690-698
    • /
    • 2000
  • The laminar boundary layer flow and heat transfer of anisotropic fluids in the vicinity of a wedge have been examined with constant surface temperature. The similarity variables found by Falkner and Skan are employed to reduce the stream wise-dependence in the coupled nonlinear boundary layer equations. The numerical solutions are presented using the fourth-order Runge - Kutta method and the distribution of velocity, micro-rotation, shear and couple stresses and temperature across the boundary layer are plotted. These results are also compared with the corresponding flow problems for Newtonian fluid over wedges. It is found that for a constant wedge angle, the skin friction coefficient is lower for micropolar fluid, as compared to Newtonian fluid. For the case of the constant material parameter K, however, the magnitude of velocity for anisotropic fluid is greater than that of Newtonian fluid. The numerical results also show that for a constant wedge angle with a given Prandtl number, Pr = I, the effect of increasing values of K results in increasing thermal boundary layer thickness for anisotropic fluid, as compared with Newtonian fluid. For the case of the constant material parameter K, however, the heat transfer rate for anisotropic fluid is lower than that of Newtonian fluid.

  • PDF

Characteristics of dose distribution for virtual wedge (가변형 쐐기필터의 선량분포에 관한 특성)

  • 김부길;김진기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • We was investigate the dosimetric characteristics of the virtual wedge and it compared to the conventional fixed wedge. Also we was evaluate the quality factor of the experimental multi-channel dosimetry system for virtual wedge. Recently virtual wedge technique and wedge fraction methods are available through the computer controlled asymmetric collimator or the independent jaw in medical linear accelerator for radiation therapy. The dosimetric characteristics are interpreted by radiation field analyzer RFA-7 system and PTW-UNIDOS system. Experimental multi-channel dosimetry system for virtual wedge was consists of the electrometer, the solid detector and array phantom. The solid detectors were constructed using commercially diodes for the assessment of quality assurance in radiotherapy. And it was used for the point dose measuring and field size scanning. The semiconductor detector and ion chamber were positioned at a dmax, 5 cm, 10 cm, 20 cm depth and its specific ratio was determined using a scanning data. Wedge angles in fixed and virtual type are compared with measurements in water phantom and it is shown that the wedge angle 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$were agree within 1$^{\circ}$ degree in 6, 10 MV photon beams. In PDD and beam flatness, experimental multi-channel disimetry system was capable of reproduceing the measured values usually to within $\pm$2.1% the statistical uncertainties of the data. It was used to describe dosimetric characteristics of virtual wedge in clinical photon beams. Also we was evaluate optimal use of the virtual wedge and improve the quality factor of the experimental multi-channel dosimetry system for virtual wedge.

  • PDF

The Effects of Femorotibial Angle of Contact laterally Wedged Insoles With Strapping of varying elevations (밀착형 외측 쐐기 스트랩 깔창의 높이에 따라 대퇴경골각에 미치는 영향)

  • Lee, Sang-Yong;Park, Sung-Jin
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.44-50
    • /
    • 2006
  • The purpose of this study is to assess the radiographic effects of normal person with contact laterally wedged insoles with strapping of varying elevations. Eight person who were randomized into group according to their birth dates and wedge elevation, participants wore contact laterally wedged insoles with strapping with elevation of 9, 15, 21mm. Standing radiographs were used to analyze the femorotibial angle for each subject, The result of repeated measures ANOVA's reveled that laterally wedged insoles with strapping of varying elevations produced significantly the femorotibial angle. The degree of change in femorotibial angle with the insole with strapping was effected by the tilt of the lateral wedge(P<0.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and later compartment forces in the knee varus-valgus deformity.

  • PDF

Flow rate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure (Segmental Wedge를 이용한 차압식 유량측정 방법)

  • Yoon J.Y.;Sung N.W.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.22-28
    • /
    • 2006
  • The discharge coefficient in segmental wedge haying ninety degrees yeller angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured. Main purpose of this work is placed on specifying the characteristic of discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and suggestion for the fixed location of pressure taps useful. Although the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated. The Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000.