• 제목/요약/키워드: Wearable Device

검색결과 559건 처리시간 0.025초

Design and Implementation of a Wearable LED Display Device

  • Shin, Seung-Hyeok
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권10호
    • /
    • pp.7-13
    • /
    • 2015
  • Wearable device, next generation smart device, is consistently growing. The flexible display will be a kind of display in the wearable device. The flexible display technology is now evolving with end-user requirement such as portability and easy installation. Previous wearable display products still have some difficulties in manufacturing and in flexibility whole device. But it can be a flexible display with LED device and utilized in commercial area. In this paper, we propose a driver to control the LED display and implement a flexible LED display system.

웨어러블 장치를 이용한 건설사고 예방 시스템 개발 기초 연구 (Basic Study on Safety Accident Prevention System Development Using Wearable Device)

  • 류한국;강진우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.55-56
    • /
    • 2018
  • In order to reduce the risk of accidents, we proposed a construction safety management system combined with wearable device and LoRa (Low-Range Wireless Network) communication method to apply the usefulness of Internet (IoT) technology which means "everything connected". to construction safety management Management system. The proposed wearable safety device is a device that relays information exchange between wearable safety device and safety management server by LoRa wireless communication method. The safety management server can store workers bio-data and perform big data analysis. If a risk factor is determined from the analysis result, a warning is sent to the wearable safety device and the manager's application. The goal of this system is to prevent construction workers from entering the dangerous area that is not suitable for work, and to prevent safety accidents caused by human cause by detecting abnormal condition during work.

  • PDF

웨어러블 디바이스 기반의 게임콘텐츠 전망 연구 (A Prospective Study of Game Content based on Wearable Device)

  • 백재용;장효진;김영재
    • 디지털산업정보학회논문지
    • /
    • 제11권1호
    • /
    • pp.145-155
    • /
    • 2015
  • The game industry has changed along with the advancement of device technology. The wearable, a recently appeared device will create new demand in this saturated age of the smart devices. The game industry's content targeted towards the wearable devices will play an important role as main driving source. For this reason, this research studies the development aspect and the current technical capabilities of games' platforms and contents by analyzing the contrast between the results of features and current situations of the wearable market. Consequently, we define the prospects of game content for wearable device. We also expect that the new style of the game content, combined with cloud game, augmented reality game and virtual reality game will appear in the next generation platforms gearing towards the wearable devices.

Strategic Approach to Privacy Calculus of Wearable Device User Regarding Information Disclosure and Continuance Intention

  • Cho, Ji Yeon;Ko, Daesun;Lee, Bong Gyou
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권7호
    • /
    • pp.3356-3374
    • /
    • 2018
  • The healthcare and fitness wearable-device market is considered as the driving force of the entire wearable device market. However, there are concerns with respect to information privacy because wearable devices constantly collect sensitive data such as individuals' health information. Thus, there is a need for a comprehensive understanding from the perspective of information privacy concerns and related behavior. This study investigates factors considered in the privacy calculus of wearable fitness devices, and verifies differences obtained by the privacy calculus process according to the frequency of exercise. The results obtained from a survey of 248 undergraduate students in Korea revealed that service providers should consider users' interests and exercise characteristics in order to mitigate their privacy concerns and encourage continuous use of wearable devices. This study provides useful insights pertaining to users of wearable fitness devices, and targets researchers and practitioners.

웨어러블 디바이스의 기술 요소 (The technical elements of the wearable device)

  • 심현보
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.259-263
    • /
    • 2014
  • ICT 분야에서 2014년의 주목할 만한 이슈 중 하나가 "입는 컴퓨터(Wearable Computer)" 즉 "Wearable Device" 시대의 개막이다. 삼성 갤럭시 기어, 구글 글래스, 그리고 애플 워치와 같은 제품들을 웨어러블 디바이스라고 한다. MIT 미디어 랩의 정의에 따르면 웨어러블 디바이스는 신체에 부착하여 컴퓨팅 행위를 할 수 있는 모든 것을 지칭하며 일부 컴퓨팅 기능을 수행할 수 있는 애플리케이션까지 포함하고 있다. 웨어러블 디바이스는 또 하나의 두뇌다. 웨어러블 디바이스가 대중화되면 달라지는 것이 수없이 많아질 것이다. 일단 두 손이 자유로워진다. 내 몸이 24시간 인터넷과 연결되기 때문이다. 단지 스마트폰이나 디바이스를 몸에 붙인다는 수준이 아니라 디바이스가 바로 우리 몸의 외부에 연결되어 있는 두뇌 역할을 하게 될 것이다. 본 논문에서는 이러한 웨어러블 디바이스의 기술 요소를 관련 기업들 별로 분석해 본다.

  • PDF

Detection of Arrhythmias by Holter Monitoring and Use of Wearable Electrocardiography Devices Holter and wearable devices for arrhythmia detection

  • Ji Yeon Chang;Jae Kyung Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제11권2호
    • /
    • pp.310-314
    • /
    • 2023
  • In this paper, we show that the limitations of Holter monitoring and Wearable Electrocardiogarphy Devices and their arrhythmia detection. Sudden death caused by cardiovascular disease, often referred to as the "silent killer" due to its unpredictable nature, is a major health concern. Electrocardiography (ECG) is a basic diagnostic tool for detecting heart disease, but its limitations make it difficult to detect arrhythmia, a significant indicator of an irregular heart state. To address this limitation, a long-term continuous ECG recording device has been developed, Holter ECG device and wearable device. A significant number of studies have focused on the differences between Holter monitoring and wearable devices. The Holter tests were useful for detecting regularly occurring arrhythmias, whereas wearable patches were better at detecting random and infrequent arrhythmias. Wearable patches were effective in detecting episodes of arrhythmia and myocardial ischemia. Despite the concern, wearable devices had less signal loss than Holter monitoring and patients also preferred wearable devices over Holter monitoring due to convenience. These results could mean that the wearable devices can perfectly replace the Holter test.

기술 및 개인적 특성이 헬스케어 웨어러블 디바이스 수용의도에 미치는 영향에 관한 연구 (An Empirical Study on Acceptance Intention Towards Healthcare Wearable Device)

  • 이상일;유왕진;박현선;김상현
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제25권2호
    • /
    • pp.27-50
    • /
    • 2016
  • Purpose The purpose of this study is to examine the effect of the acceptance intention towards healthcare wearable device in Korea. Specifically, this study attempted to identify the relationships among the acceptance intention towards healthcare wearable device, technical characteristics and user's personal characteristic based on UTAUT(Unified Theory of Acceptance and Use of Technology) model. Design/methodology/approach For this purpose of research, we conducted against consumers who use the wearable devices and we collected data from 219 wearable device users. The analyses were conducted using SPSS and AMOS19.0 which is powerful structural equation modeling (SEM) software. Findings The main findings are as followed; First, functional diversity, wearability, trend sensitivity and health perception are significantly related to performance expectancy, while visual aesthetic and enjoyment are not significantly related. Second, performance expectancy and effort expectancy are significantly related to acceptance intention towards healthcare wearable device. Third, effort expectancy is significantly related to performance expectancy.

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제36권4호
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

Deterministic Multi-dimensional Task Scheduling Algorithms for Wearable Sensor Devices

  • Won, Jong-Jin;Kang, Cheol-Oh;Kim, Moon-Hyun;Cho, Moon-Haeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권10호
    • /
    • pp.3423-3438
    • /
    • 2014
  • In recent years, wearable sensor devices are reshaping the way people live, work, and play. A wearable sensor device is a computer that is subsumed into the personal space of the user, and is always on, and always accessible. Therefore, among the most salient aspects of a wearable sensor device should be a small form factor, long battery lifetime, and real-time characteristics. Thereby, sophisticated applications of a wearable sensor device use real-time operating systems to guarantee real-time deadlines. The deterministic multi-dimensional task scheduling algorithms are implemented on ARC (Actual Remote Control) with relatively limited hardware resources. ARC is a wearable wristwatch-type remote controller; it can also serve as a universal remote control, for various wearable sensor devices. In the proposed algorithms, there is no limit on the maximum number of task priorities, and the memory requirement can be dramatically reduced. Furthermore, regardless of the number of tasks, the complexity of the time and space of the proposed algorithms is O(1). A valuable contribution of this work is to guarantee real-time deadlines for wearable sensor devices.

Wearable Human Health-monitoring Band using Inkjet-printed Flexible Temperature Sensor

  • Han, Dong Cheul;Shin, Han Jae;Yeom, Se Hyeok;Lee, Wanghoon
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.301-305
    • /
    • 2017
  • This paper presents a wearable human health-monitoring band. The band consists of a body temperature detector (BTD) and a hear rate detector (HRD). The BTD and HRD are realized using an inkjet-printed flexible temperature sensor and a commercial heart rate sensor module, respectively. The sensitivity of the fabricated BTD was found to be $-31/^{\circ}C$ with a linearity of 99.82%. The HRD using the commercial heart rate sensor module has a good performance with a standard deviation of 0.85 between the data of a commercial smart watch and the fabricated HRD.